11
6643-22901
Type tests and environmental conditions
Environmental phenomena
Basic standard
Description
Test levels
Electrostatic discharge
EN 61000-4-2
Enclosure
Contact: ±6 kV
Air: ±8 kV
Fast transients
EN 61000-4-4
Power port
±2 kV
Ethernet
Status out/Digital in
Serial ports
Enclosure
Surge
EN 61000-4-5
Power port
L-L: ±0.5 kV, 2
Ω
, 18 μF
L-E: ±2 kV, 42
Ω
, 0.5 μF
L-L: ±1 kV, 42
Ω
, 0.5 μF
L-E: ±2 kV, 12
Ω
, 9 μF
L-L: ±1 kV, 12
Ω
, 9 μF
Ethernet
L-E: ±2 kV, 2
Ω
, 0.5 μF
Status out/Digital in
L-E: ±2 kV, 42
Ω
, 0.5 μF
L-L: ±1 kV, 42
Ω
, 0.5 μF
RS-232
L-E: ±2 kV, 2
Ω
, 0.5 μF
RS-422/485
L-E: ±2 kV, 42
Ω
, 0.5 μF
Power frequency magnetic field
EN 61000-4-8
Enclosure
300 A/m; 0, 16.7, 60 Hz
1000 A/m; 50 Hz
Pulsed magnetic field
EN 61000-4-9
Enclosure
300 A/m
Radiated RF immunity
EN 61000-4-3
Enclosure
20 V/m @ (80 – 2700) MHz
10 V/m @ (2700 – 6000) MHz
1 kHz sine, 80% AM
Conducted RF immunity
EN 61000-4-6
Power port
10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Ethernet
Status out/Digital in
Serial ports
Earth port
Radiated RF emission
CISPR 16-2-3
ANSI C63.4
(FCC Part 15)
Enclosure
Class B / DNV bridge
Conducted RF emission
CISPR 16-2-1
ANSI C63.4
(FCC Part 15b)
Power port
Class B / DNV bridge
Ethernet
Class B
Содержание Lynx DSS L106-S2 EX
Страница 2: ...2 6643 22901 ...
Страница 25: ...25 6643 22901 Dimensions Measurements are stated in millimeters 92 1 Min 4mm Max 7 5mm 34 1 96 1 52 1 100 1 ...
Страница 26: ......