16
6072-2021
RS-422/485
Example: Multidrop
Connection of RS-422, RS-485
LD-63B
RX1
RX2
TX2
TX1
RX1
RX2
TX2
TX1
LD-63B
LD-63B
RS-422/485
RS-422/485
RX1
RX2
TX2
TX1
1
2
3
4
5
L
N
RS-422/485
POWER
R+
Rx2
Tx1
Tx2
R- T+
T-
1
2
3
4
5
L
N
RS-422/485
POWER
R+
Rx2
Tx1
Tx2
R- T+
T-
R
+
RS-422
equipment
R
–
T
+
T
–
RS-485
equipment
T
+
T
–
*) The designations A, A’, B, B’ are sometimes use instead of T+, T–, R+, R–.
Despite the standard, different manufacturers name the signals differently.
The first step in fault finding is to reverse the cables (swap T+ with T– and/or
R+ with R–). Please note that this should be done only at one end!
*
*
S1:2 ON
NB
When a multidrop connection ends with an LD-63B and the fibre pair
is connected on channel 2, the switch S1:2 must be set (Y-function)
Y-funktion