Installation

The Terminal Adapter should be connected in the following way:
Power connection is made through screw-block 
at bottom right corner.
For HV-version a 3-pole connector, 
and for LV-version a 2-pole connector is used.

Computers or other equipment
are connected through an 
RS-232/V.24 or RS-485 connec-
tion. The RS-232/V.24 uses a 
9-pole D-sub and the RS-485 
a 9-pole screw connector. 
Do not use ribbon cable 
for RS-232/V.24 connections.

Light emit-

ting diodes

Screw-block 
for RS-422/485 
connection

9-pole D-sub 
for RS-232/V.24 
connection

Power 
connection

Line connec-

tion RJ-45

Alarm 

connection

RS-232/V.24 Connections

Pinouts for the 9-pole D-sub

O

1

109

DCD/Data Carrier Detect

O

2

104

RD/Received Data

I

3

103

TD/Transmitted Data

I

4

108/2

DTR/Data Terminal Ready

5

102

SG/Signal Ground

O

6

107

DSR/Data Set Ready

I

7

105

RTS/Request to Send

O

8

106

CTS/Clear to Send

O

9

125

RI/Ring Indicator

Signal description

= input = output on ID-90

Direction

Pin
no.

CCITT V.24

Description

6607-2213

ID-90 LV

Содержание ID-90

Страница 1: ...termo Teleindustri AB 2000 REV A Galvanic Isolation Transient Protection Balanced Transmission CE Approved 1 2 3 4 9 8 7 6 5 AUDIN Composants syst mes d automatisme 8 avenue de la malle 51370 Saint Br...

Страница 2: ...aracter SMS paging mes sages or establish automatic data connections making the unit ideal for alarm monitoring and remote diagnostics The ID 90 features DIP switch configuration and can be programmed...

Страница 3: ...crew terminals Interface 2 RJ 45 Transmission speed Interface 1 Up to 115 2 kbit s Interface 2 Up to 128 kbit s Command interface Interface 1 AT command Configurator remote local X3 PAD Hotline DTR Tx...

Страница 4: ...nector Do not use ribbon cable for RS 232 V 24 connections Light emit ting diodes Screw block for RS 422 485 connection 9 pole D sub for RS 232 V 24 connection Power connection Line connec tion RJ 45...

Страница 5: ...s R R T T can be various between different manufactures ID 90 uses the defination that in a MARK condition R T is more negative than R T Description Direction Terminal Name RS 422 485 interface connec...

Страница 6: ...striction on the distance between units but only specifying the maximum round trip delay to be 10 to 14 s giving a d1 of 100 to 200 m depending on the cable impedance Up to 8 ID 90 in combination with...

Страница 7: ...the far end from the NT at a distance of d3 from the far end terminating resistor TR The range of d3 is from 25 to 50 m giving at least d1 500 m d2 see Short Passive Bus Diagram specifies practically...

Страница 8: ...cted between the alarm input common and the four inputs via making or breaking contacts The inputs is not polarity sensitive but all inputs must use the same common The alarm inputs can use any mix of...

Страница 9: ...nsmitted RTS Request to Send LED showing the status of the handshake line RTS from DTE LED is ON when DTE requests to send data DCD Data Carrier Detect LED showing the status of the handshake line DCD...

Страница 10: ...40 VAC Stored setting from ID 90 database is used S1 Related AT command ON 1 2 3 4 5 6 7 8 No Parity 8 data bits S1 AT prty 0 AT dbits 8 ON 1 2 3 4 5 6 7 8 Even Parity 8 data bits S1 AT prty 1 AT dbit...

Страница 11: ...DSR ON indicates ISDN connection is established and synchronized DCD always ON S1 AT S1 AT C DSR ON indicates ISDN connection is established and synchronized DCD ON indicates ISDN connection is estab...

Страница 12: ...ion AT B0 Related AT command S2 ON 1 2 3 4 1 200 bit s AT B1 S2 ON 1 2 3 4 2 400 bit s AT B2 S2 ON 1 2 3 4 4 800 bit s AT B3 S2 ON 1 2 3 4 9 600 bit s AT B4 ON 1 2 3 4 S2 19 200 bit s AT B5 ON 1 2 3 4...

Страница 13: ...7 8 HDLC transparent DTE data octets packed into HDLC frames S3 ATB4 ON 1 2 3 4 5 6 7 8 Byte transparent raw B channel data S3 ATB5 ON 1 2 3 4 5 6 7 8 X 75 SLP S3 ATB10 ON 1 2 3 4 5 6 7 8 V 120 async...

Страница 14: ...AT cmds 0 ON 1 2 3 4 5 6 7 8 X 3 PAD S3 AT cmds 1 ON 1 2 3 4 5 6 7 8 Hot line DTR call S3 AT cmds 6 ON 1 2 3 4 5 6 7 8 Hot line TxD call S3 AT cmds 7 ON 1 2 3 4 5 6 7 8 Reserved S3 ON 1 2 3 4 5 6 7 8...

Страница 15: ...8 Local flow control is set to hardware handshake RTS CTS S4 AT K3 ON 1 2 3 4 5 6 7 8 Local flow control is set to software handshake XON XOFF CTS is always ON RTS ignored S4 AT K4 AT R1 ON 1 2 3 4 5...

Страница 16: ...read at Power on and override the current database set ting If an AT command or Configurator command given after Power on addressing the same parameter as a DIP switch setting the command will in tur...

Страница 17: ...17 6607 2213 OWN COMMENTS...

Страница 18: ...18 6607 2213 OWN COMMENTS...

Страница 19: ......

Страница 20: ...munications Ltd Unit 14 Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E Mail sales westermo co uk Web www westermo co uk Westermo Dat...

Отзывы: