background image

www.westermo.com

Ibex-RT-370 Series

WLAN 802.11 Access Point with Optical Ethernet

Содержание Ibex-RT-370 Series

Страница 1: ...www westermo com Ibex RT 370 Series WLAN 802 11 Access Point with Optical Ethernet ...

Страница 2: ...Conformity 10 3 Product Description 11 3 1 Product Description 11 3 2 Available Models 11 3 3 Hardware Overview 12 3 3 1 Front Side View 12 3 3 2 Front Side Label 12 3 3 3 Rear Side Label 13 3 3 4 Interface Ports View 13 3 4 Connector Information 13 3 4 1 Power Input Connection 13 3 4 2 1000BASE FX Port 13 3 4 3 Ethernet Port 14 3 4 4 Antenna Ports 15 3 5 LED Indicators 15 3 6 Factory Reset 16 3 6...

Страница 3: ...used More information about Westermo can be found at www westermo com 1 2 About This Guide This guide is intended for installation engineers and users of the Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools are available at www westermo com 1 4 License and Copyr...

Страница 4: ...damage WARNING Indicates a potentially hazardous situation Possible death or major injury Major damage to the Product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides information in order to avoid misuse of the product confusion or misunderstanding No personal injury Minor damage to the product NOTE Used for highlighting ge...

Страница 5: ...ed and operated by qualified service personnel and installed info an apparatus cabinet or similar where access is restricted to service personnel only For Ibex products outdoor installation is allowed During installation ensure a protective earthing conductor is first connected to the protective earthing terminal Westermo recommends a cross sectional area of at least 4 mm2 Upon removal of the prod...

Страница 6: ...ed between the antenna of the product and personell during operation CAUTION HOT SURFACE Be aware of that the surface of this product may become hot When it is operated at high temperatures the external surface may exceed Touch Temperature Limit according to the product s relevant electrical safety standard CAUTION CORROSIVE GASES If the product is placed in a corrosive environment it is important...

Страница 7: ...mo technical support NOTE Devices not used shall be kept in the factory sealed moisture barrier bag Open unsealed devices should not be kept unpowered for more than 30 days 2 4 Product Disposal This symbol means that the product shall not be treated as unsorted municipal waste when disposing of it It needs to be handed over to an applicable collection point for recycling electrical and electronic ...

Страница 8: ...conditions for Broadband Data Transmission Systems Mechanical Shock and vibration EN 50125 3 Outside the track Insulation Coordination and test EN 50124 1 Railway applications Insulation coordination Radio Communication ETSI EN 300 328 Wideband transmission systems Data transmission equipment operating in the 2 4 GHz ISM band and using wide band modulation techniques ETSI EN 301 893 5 GHz RLAN IEE...

Страница 9: ...mful interference in a residential installation This product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this product does cause harmful interference to radio or television r...

Страница 10: ... de licence L exploitation est autorisée aux deux conditions suivantes l appareil ne doit pas produire de brouillage l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement NOTE This product contains the IC Certification number 9301A 103902DT50 2 5 5 Europe Simplified Declaration of Conformity Hereby W...

Страница 11: ...s information is available in local LED status indicators and through SNMP WebGUI The Ibex RT 370 access point is designed to withstand tough environmental conditions and can be remotely managed using web browser or SNMP management tools Integrating hardware software and network design support tools this access point offers advanced capabilities the lowest total cost of ownership and will create t...

Страница 12: ...of interface ports and LED indicators 3 3 2 Front Side Label No Description Remarks 1 QR code The data matrix is AAAAAAAAARR 1 VV SSSSSSSS YYWW AAAAAAAAA Article number RR Region code VV Product revision SSSSSSSS Serial number YY Manufacturing Year WW Manufacturing Week 2 Manufacturing date The Date Format is YYWW YY Manufacturing Year WW Manufacturing Week 3 Serial number 4 Article number Figure ...

Страница 13: ...r 693 male power connector 3 PE Marking Position Direction Description AC PE Protective Earth 1 Phase AC Phase terminal 2 Neutral AC Neutral terminal 3 Not used Table 4 Power input connection 3 4 2 1000BASE FX Port The product includes an optical Ethernet port X1 which supports 1000 Mbit s operation ODC 2 male FO connector Marking Position Direction Description X1 1 Out TX 2 In RX C O M P L I A N ...

Страница 14: ...ticeable decrease the performance and need to be removed by appropriate cleaning devices 3 4 3 Ethernet Port The product includes an Ethernet port X2 which supports auto negotiated 10 Mbit s 100 Mbit s and 1000 Mbit s operation Automatic MDI MDIX crossover is supported for 10BASE T 100BASE T 1000BASE T operation M12 X coded 8 pin female Ethernet connector according to IEC 61076 2 109 Marking Posit...

Страница 15: ...ected to an external WLAN antenna to make use of the scanning monitoring functions NOTICE Any unused antenna ports must be properly terminated with 50 Ohm otherwise the device might be damaged when power is applied to a non terminated antenna port NOTICE For lightning protection of the antenna interfaces external lightning protectors need to be installed to the antenna feed NOTE To ensure specifie...

Страница 16: ...et Plug X coded Table 6 Factory reset plug 3 6 1 Factory Reset Procedure Step Description 1 Plug the factory reset adapter to the X2 Ethernet interface 2 Power the product 3 Wait until factory reset adapter is detected This is indicated by solid ORANGE OPR LED and RED ERR LED 4 Remove factory reset adapter within 15 seconds 5 Successful initiation of the factory reset is indicated by blinking ORAN...

Страница 17: ...Ibex RT 370 Series User Guide Westermo Network Technologies 17 3 7 Dimensions Dimensions are stated in mm and are regardless variants Figure 8 Dimensional drawing ...

Страница 18: ...rs must be covered by a protective cap delivered with the product tightened to the specified torque in order to fulfill the specified ingress protection code 4 2 Earth Connection There are two earth connection points At the AC connector there is the connection point for the protective earthing conductor and at the grounding screw of the Ibex RT 370 housing is the connection point for the protectiv...

Страница 19: ... power antenna and FO connectors is 1 0 Nm and for the M12 Ethernet connector 0 6 Nm NOTE This product has no replaceable fuse and should be connected via an external fuse for protection NOTE External connector Binder 99 4222 00 04 outer cable diameter 6 9 5 mm or Binder 99 4222 14 04 outer cable diameter 10 12 mm shall be used in order to fulfill the specified ingress protection code at the power...

Страница 20: ...ow is not blocked and that there is enough spacing around the device Figure 10 Installation with natural convection airflow When operating the device at high ambient temperatures it is recommended to mount the device to a metallic base plate to improve the heat dissipation The base plate increases the surface to spread the heat Figure 11 Improved heat transfer based on fixing plate Re e r r r ...

Страница 21: ...l operation does not cause temperature alarms Improve installation conditions or RF parameters in case of any temperature alarms 4 5 Replacement of Product Disconnect all cables and unscrew the product from the wall Mount the replacement product and reconnect all cables observing the instructions in Connection of Cables MTTR Mean Time To Repair i e time for replacement of product is 10 minutes CAU...

Страница 22: ...nnector ODC 2 male Wavelength 1310 nm Data rate 1000 Mbit s Transmit power 16 7dBm Receiver sensitivity 32dBm or better Receiver Saturation2 3dBm Ethernet TX Connector M12 X coded female Electrical specification IEEE std 802 3 Data rate 10 Mbit s 100 Mbit s 1000 Mbit s manual or auto Duplex Full or half manual or auto Transmission range Up to 100 m with CAT5e cable or better Cabling Shielded cable...

Страница 23: ...11abgn Access Point A1 A3 1x 802 11abgn Monitoring A4 WLAN frequency bands 2 400 2 4835 GHz 5 150 5 350 GHz 5 470 5 725 GHz 5 725 5 850 GHz Transmitting power A1 A3 Max conducted transmit power per port within the whole frequency range up to 22dBm NOTICE Depending on the installation country there are frequency band restrictions and output power limitations NOTICE Unused antenna port must be termi...

Страница 24: ... frequency magnetic field EN 61000 4 8 Enclosure 300 A m continues DC 16 7 Hz 50 Hz 60 Hz Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m Radiated RF immunity EN 61000 4 3 Enclosure 20 V m 80 AM 1kHz at 80 MHz to 2 GHz 5 V m 80 AM 1kHz at 2 GHz to 2 7 GHz 3 V m 80 AM 1kHz at 2 7 GHz to 6 GHz Conducted RF immunity EN 61000 4 6 AC power port 10 V 80 AM 1kHz from 0 15 to 80 MHz Ethernet ports An...

Страница 25: ...tional endurance test 2 3 m s2 random 5 to 2000 Hz 3 x 4 h Shock4 EN 60068 2 27 Operational 20 m s2 11 ms 3 x 6 shocks half sine MIL STD 810 M516 7 10 g 11 ms 3 x 6 shocks saw tooth Weight 1900 gr Degree of protection EN 60529 Enclosure IP665 Cooling Convection Pollution degree EN 62368 1 PD2 Conformal coating type IPC A 610 Electronic modules AR Acrylic Table 9 Environmental and mechanical condit...

Страница 26: ...s Institute FCC Federal Communication Commission FLOSS Free Libre Open Source Software FO Fiber Optic IEC International Engineering Consortium IC Industry Canada ID Identification I O Input Output IP Ingress Protection ISO International Standardization Organisation LAN Local Area Network LED Light Emitting Diode MIMO Multiple Input Multiple Output MTBF Mean Time between Failure MTTR Mean Time to R...

Страница 27: ...mo Network Technologies 27 7 Revision Notes Revision Date Rev A 2016 12 First revision Rev B 2017 03 Regulation part updated Rev C 2017 08 Product label example updated for RED directive Rev D 2020 09 Updated for new user manual template ...

Страница 28: ...REV D 6623 2280 2020 09 Westermo Network Technologies AB Sweden ...

Отзывы: