LED Status
Description
PWR
OFF
No internal power
ON
Internal Power OK
TD
OFF
No serial data transmitted from the unit,
(RS-232 or RS-422/485)
ON
Serial data transmitted from the unit, (RS-232 or RS-422/485)
RD OFF
No serial data received to the unit, (RS-232 or RS-422/485)
ON
Serial data received to the unit, (RS-232 or RS-422/485)
RTS OFF
No RTS to the RS-232 interface or RS-422/485 transmitting.
ON
RTS to the RS-232 interface or RS-422/485 receiving.
CTS
OFF
No CTS from the RS-232 interface
ON
CTS from the RS-232 interface
LINK OFF
No Ethernet link.
Cable not connected.
ON
Good Ethernet link.
Flash
Ethernet data is transmitted or received, traffic indication.
STAT OFF
Normally
Off
ON
Telnet session established to Telnet diagnostics service or
Ongoing configuration by Web tool
RC
OFF
DIP switch settings are valid.
ON
One or more DIP switches are overrid by remote configuration
SPD
ON
Ethernet 100 Mbit/s
OFF
Ethernet
10
Mbit/s
DPX ON
Full
duplex
OFF
Half
duplex
22
6616-2202
LED Indicators
Power
Transmit data
Receive data
Request to send
Clear to send
Status
Remotely controlled
Speed Integrated in RJ-45
Green
Duplex Integrated in RJ-45
Yellow
8
7
6
5
4
3
2
1
Ethernet
Ethernet TX connection (RJ-45 connector), automatic MDI/MDI-X crossover*.
Contact Signal Name
Direction
Description/Remark
1
TD+
In/Out Transmitted/Received
data
2
TD–
In/Out Transmitted/Received
data
3
RD+
In/Out Transmitted/Received
data
4
NC
5
NC
6
RD–
In/Out Transmitted/Received
data
7
NC
8
NC
Shield
HF-connected
CAT 5 cable is rec-
ommended.
Unshielded (UTP) or
shielded (STP) con-
nector might be used.
* Depend of settings on S1; 6, 7 and 8.