Section VE2-848-CK6-20A

4

1006IARC

Figure 4.  Ground Lug Stud Location

Ground lug

installs on

inside wall

Ground studs are #10-32,

and are 0.625" apart, on centers

7.

Attach panel to wall. 

Lift the panel and align the holes in

the mounting ears with the drilled holes in the wall, then
insert and tighten the mounting screws (not provided).

- GROUNDING NOTE -

Always follow local safety precautions and standard operating proce-
dures for grounding the equipment when installing, upgrading, repairing
or maintaining equipment. Any instructions or information contained
herein is subordinate to local codes, operating procedures or practices.

2.4

Making Ground Connections

2.4.1

The Westell VE panels are shipped with a ground lug

(in a bag of parts) that accepts a #6 ground wire for wall-mount
applications. The installer should locate the ground lug and
hex-nut from the bag of parts shipped with the panel and install
the lug on the post located on the panel’s inside wall, securing
the lug to the post with the nut (see Figure 3). The installer then
makes an earth/chassis ground connection to the lug using a #6
ground wire, per local local company practice and installation
procedures for equipment grounding and bonding.

2.4.2

If the VE panel is installed in a relay rack, the #6

ground lug and nut is not required, but a bond wire may be used
to connect the VE panel’s chassis to the common ground or
bond for the relay rack or cabinet, per local procedures.

2.5

Making Installer Connections

After the panel is mounted, installer connections can be made
to the VE-2848C-K6, as explained in the paragraphs below.
Refer to Figure 5 as needed.

- CAUTION -

Use care when installing and removing couplers, jacks, and
connectors - 

do not force into place

. If resistance is

encountered, check for debris in or near the coupler or hole.
Then gently re-insert the coupler, jack, or connector.

2.5.1

Installing Couplers

Provided with the VE-2848C-K6 panel is a detachable LGX-
type panel which contains 6 Keystone-type coupler positions
(see Figure 8) equipped with blank hole covers. Order and
install couplers per the specific application, company practice,
or service desired. Follow the steps below to install the couplers
in the panel.

1. Call Westell to order the couplers of choice to insert into

the panel for the specific application (see Table 4).

2. Remove the LGX-type panel by pulling on the two Nylatch

fasteners at the side of the panel.

3. Remove (from the rear) the blank hole cover from the

LGX-type panel’s first Keystone-type hole position.

4. At the rear of the LGX-type panel, align the first coupler

with the first empty hole, angle the back of the coupler
down so its top angled tab fits under the hole’s top edge,
then press the coupler into the hole until it snaps in place.

5. Repeat Steps 3-4 for all couplers to be installed.

6. Re-install the LGX-type panel onto the VE

-

2848C

-

K6

.

7. Order and use optional D-rings, a lacer bar, or a front tray

(see Part 3) for cable management of any cable slack.

8. Use the circuit ID card to identify all coupler positions.

2.5.2

Connecting Network/Telco Cables

Network/Telco connections are made to the female Amphenol
connectors at the back of the VE-2848C-K6 panel (Figure 6).
See Table 2 for lead designations, pin-outs, and wire colors for
the Amphenol connectors, and to Figure 5 as needed.

1.

Prepare upstream connection. 

Remove the protective

connector insert or cover from the back of the DS1 OUT
connector at the rear of the MUX (or upstream equip-
ment).

2.

Connect cable to panel’s XMT OUT connector. 

Route a

male, 32-pair, Amphenol cable from the MUX (or up-
stream equipment) to the female, 32-pair, Amphenol
XMT OUT connector at the back of the Westell
VE2848-CK6 panel, then connect the connectors.

Figure 5.  Cabling Block Diagram

DS1 Input

1−28

1−28

A90-VE2848CK6

DS1 Jack Panel

28 DS1

DS1 Output

DS1 MUX RECEIVE

DS1  MUX TRANSMIT

DS1 CPE TRANSMIT

DS1 CPE RECEIVE

MUX

* 32-pair AMP connector

XMT

OUT*

RJ48C

Pins

4 & 5

CSU

RCV

XMT

RCV

IN*

RJ48C

Pins

1 & 2

Содержание VirtualEdge VE-2848C-K6 1-RU

Страница 1: ...ded inside a clear plastic packet which allows installers to label each cou pler and jack position The VE 2848C K6 comes equipped with the components shown in Table 1 Optional features in clude couple...

Страница 2: ...andFigure 3 provide further details Screws to attach the mounting ears to the panel are provided as well as screws to mount the panel to a rack 2 1 Mounting in a 19 Rack The panel is shipped from the...

Страница 3: ...hardware provided The ear s short flange abuts the panel 5 Attach panel to rack Lift the panel and attach it to the rack channels in the correct vertical rack position Align the holes in the ear s lon...

Страница 4: ...alling Couplers Provided with the VE 2848C K6 panel is a detachable LGX type panel which contains 6 Keystone type coupler positions see Figure 8 equipped with blank hole covers Order and install coupl...

Страница 5: ...C cable 32 pair male Amphenol cables field provided 3 Perform cable management on the cable per company practice using the cable tie downs on the panel s rear tray 4 Connect cable to RCV IN connector...

Страница 6: ...the D ring when properly installed 4 Align the top hole of D ring hole with corresponding panel or ear hole and insert the provided screw from the back side through the aligned set of holes panel and...

Страница 7: ...57 email rgmdept westell com Replacements will be shipped in the fastest manner consistent with the urgency of the situation Westell will continue to repair or replace faulty equipment beyond the warr...

Отзывы: