background image

Section SDSĆ548Ć6LNĆ204

030Ć101328 Rev. A 

R

0208I4RA

5

3.7

Remote (Manual) Alignment

While  in  command  mode  (1014Hz  present),  the  STC should

verify/record the level received. The STC then initiates manual

alignment by sending 1004Hz to INTELIPORT. Upon detecting

1004Hz, INTELIPORT returns 2814Hz. The STC should verify/

record  the  level  received  at  2814Hz,  then  sends  2804Hz  to

INTELIPORT. Upon detecting 2804Hz, INTELIPORT returns

414Hz.  The  STC  should  verify/record  the  level  received  at

414Hz,  then  sends  404Hz.  Upon  detecting  404Hz,  INTELIĆ

PORT  returns  1814Hz  for  120  seconds.  The  STC  should

verify/record the level received at 1814Hz, then has the option

of aligning the circuit to 3 tones or 4 tones.

Ć NOTE Ć

INTELIPORT provides a builtĆin five minute waiting period for

each tone (1004, 2804, and 404Hz) to be returned by the STC.

If no tone is sent to INTELIPORT during the 5Ćmin time frame,

INTELIPORT sends an error tone (rampĆdown tone of 3014Hz

to 314Hz; holding the 314Hz tone for 10 seconds) and returns to

idle.  The  rampĆdown  tone,  in  this  case,  indicates  the  remote

alignment mode has timed out via the 5Ćmin timeĆout feature.

3.8

3ĆTone Alignment

If a 3Ćtone alignment is required, the STC ignores the 1814Hz

tone from INTELIPORT. After 120 seconds, the 1814Hz tone

times out, INTELIPORT sets the alignment levels, sends a eiĆ

ther a rampĆup or rampĆdown tone (see paragraph 3.10), applies

a quiet termination for approximately one second, then enters

loopback (see paragraph 3.11). NOTE: The 120Ćsecond timer

can be bypassed by sending 1004Hz to INTELIPORT during the

120Ćsecond time frame.

3.9

4ĆTone Alignment

If a 4Ćtone alignment is required, the STC sends 1804Hz within

the 120Ćsecond time frame to INTELIPORT. Upon detecting

1804Hz,  INTELIPORT  aligns  to  four  tones,  sends  either  a

rampĆup  or rampĆdown tone (see paragraph 3.10), applies a

quiet  termination  for  approximately  one  second,  then  enters

loopback (see paragraph 3.11).

Upon completing the alignment, INTELIPORT automatically

outputs  a  level  of  +5  dBm  (TLP)  immediately  following  the

alignment process. If a level other than +5 dBm (TLP) is reĆ

quired, see paragraphs 3.13 thru 3.16 for details on adjusting the

XMT OUT level.

3.10

RampĆUp/RampĆDown Tone

The rampĆup tone, consisting of a series of tones ranging from

314Hz  to  3014Hz  in  ascending  order,  indicates  alignment  is

within the requirements of C5 conditioning. The rampĆup tone

also occurs whenever a 20Ćminute timer circuit times out due to

inactivity (that is, no tone sent to INTELIPORT during a test

function equipped with the 20Ćminute timeĆout feature). The

rampĆdown tone, consisting of a series of tones ranging from

3014Hz to 314Hz in descending order, indicates alignment is not

within  the  requirements  of  C5  conditioning.  The  rampĆdown

tone also occurs whenever a 5Ćminute timer circuit times out due

to inactivity (that is, no tone sent to INTELIPORT during a test

function equipped with the 5Ćminute timeĆout feature).

The  rampĆup  or  rampĆdown  tone  sequence  is  applied  for

approximately three seconds with the last tone (3014Hz in the

rampĆup sequence or 314Hz in the rampĆdown sequence) being

applied for approximately 10 seconds.

3.11

Loopback

Loopback permits verification of alignment settings. While in

loopback, the STC sends tones (404, 1004, 1804 and 2804Hz),

one at a time, to INTELIPORT. The STC should verify/record

the level of each tone as it is looped back by INTELIPORT. The

loopback circuit automatically inserts 16dB of gain to provide an

equalĆlevel loopback condition for verifying alignment settings.

Ć NOTE Ć

Loopback can be toneĆactivated from the idle state by sending

2713 Hz for more than two seconds but less than 30 seconds.

Loopback can also be activated manually by placing a ground

on the MNLB lead, pin 1.

3.12

Loopback Release

Loopback is equipped with a 20Ćminute timeĆout feature that

automatically releases the loopback condition 20 minutes after

initial activation.

When loopback is entered after the alignment mode and if reĆ

lease from loopback is desired before the 20Ćminute time frame,

the STC can send 2713Hz for 0.9 seconds, minimum. INTELIĆ

PORT  returns  to  command  mode.  At  this  point,  if  the  STC

removes and resends a second 2713Hz tone, INTELIPORT reĆ

turns to idle.

When loopback is entered from an idle state, release from loopĆ

back  is  accomplished  by  sending  2713Hz  for  0.9  seconds,

minimum.  INTELIPORT  returns  to  idle  upon  detecting

2713Hz.

Ć NOTE Ć

When loopback is manually activated, neither automatic time

out nor detection of 2713 Hz will effect loopback release. Release

of a manuallyĆactivated, neither automatic time out nor detecĆ

tion of 2713 Hz will effect loopback release. Release of a manualĆ

lyĆactivated loopback condition can only occur by removing the

ground.

3.13

XMT OUT Level Adjust Mode

INTELIPORT's operating levels are factory set for Ć3.0 dBm at

the  RCV  OUT  port,  +13.0  dBm  at  the  XMT  IN  port,  and

+5.0dBm at the XMT OUT port (refer to Table 1). The XMT

Содержание INTELIPORT I SDS5486LN

Страница 1: ...28 and updates the company contact information Whenever this practice is updated the reason will be stated in this paragraph 1 3 Product Purpose and Description Westell s INTELIPORT I Model SDS5486LN...

Страница 2: ...T monitors its transmission paths for in coming frequencies and interprets these frequencies as commands to carry out specific functions The command mode is activated from the STC by sending 2713Hz fo...

Страница 3: ...T DATA DETECTOR SEALING CURRENT LB TEK5 TEK6 23 21 MICROPROCESSOR MLBG GND PWR 35 17 19 S1 SUPPLY OFF TERM LPBK AMP S3 A 2W 4W 1200 600 150 150 600 1200 DTT ALIGN LPBK TEST HYBRID XMT OUT LEVEL ADJUST...

Страница 4: ...TELIPORT s intelligent functions which include XMT OUT Level Adjust mode remote alignment mode TLP or DLP Quiet Term Trans ponder mode or the STC can exit the command mode and return to idle NOTE The...

Страница 5: ...ioning The ramp up tone also occurs whenever a 20 minute timer circuit times out due to inactivity that is no tone sent to INTELIPORT during a test function equipped with the 20 minute time out featur...

Страница 6: ...and 3 14 above After obtaining the required XMT OUT level the STC must send 2713Hz for 0 9 seconds minimum to return to command mode 3 17 Quiet Term Transponder Operation INTELIPORT s Quiet Term Trans...

Страница 7: ...pletion if no tone is sent during the 20 minute time frame INTELIPORT after 20 minutes sends a ramp up tone drops out of the Quiet Term Transponder mode and returns to idle If release is desired befor...

Страница 8: ...the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines 5 1 Installer Connections When installing the unit in Westell s pre wired US...

Страница 9: ...ndard test procedures for digital interface equipment using the KS 108 109 or equivalent re ceiver and transmitter data test sets This equipment should not be field repaired If the equipment is suspec...

Страница 10: ...of 1014 Hz 414 Hz and enters loopback 4 Remote Manual Alignment Mode From command mode verify record level received at 1014 Hz then send 1004 Hz to INTELIPORT Upon detecting 1004 Hz INTELIPORT return...

Страница 11: ...2222 Hz is detected and removed To add Loss Send and remove 2111 Hz INTELIPORT re adjusts output level by adding 0 5 dB of loss If more loss is required repeat the process of sending and removing 211...

Страница 12: ...de send 1004 Hz 4 INTELIPORT returns 2814 Hz 5 Record level at 2814 Hz in Column B then send 2804 Hz 6 INTELIPORT returns 414 Hz 7 Record level at 414 Hz in Column B then send 404 Hz 8 INTELIPORT retu...

Страница 13: ...All tones sent from STC are TLP unless stated otherwise TLP Transponder Mode 804 Hz Activated 1 While in command mode send 804 Hz 2 INTELIPORT applies quiet termination over the XMT IN port 3 STC perf...

Страница 14: ...evel at the RCV demarcation point of Station A and Station Z STATION A SMAS SMAS STATION Z POINT B POINT C X X X X X X X X POINT A POINT D 5486LNI4 5486LNI4 OR EQUIVALENT 1 2 A B C D E F G H J A B C D...

Страница 15: ...LP for 0 9 seconds minimum Station A returns to command mode 16 From SMAS Point A send 804 Hz at TLP When SMAS Point B goes quiet remove 804 Hz 17 Close SMAS access Point B to C 18 From SMAS Point D m...

Страница 16: ...the warranty period for a nominal charge Contact Westell for details 9 SPECIFICATIONS 9 1 Ordering Specifications To order units call the telephone numbers shown in Paragraph 7 1 and please specify a...

Страница 17: ...LP Transponder activated from command mode by sending 804Hz DLP Transponder activated from command mode by sending 1304Hz When activated INTELIPORT applies quiet termination and sets 20 minute timer c...

Страница 18: ...MT OUT LEVEL TO 16dBm AFTER SETTING DESIRED XMT OUT LEVEL SEND 2713Hz FOR 0 9 SEC INTELIPORT RETURNS TO COMMAND MODE SEND 2713HZ FOR 0 9 SEC INTELIPORT RETURNS TO IDLE SEND 1804Hz START 3 TONE ALIGNME...

Отзывы: