Westell CSI-DSP85-252-C Скачать руководство пользователя страница 5

Band Plans

-6 -

Note: All frequencies are shown in MHz

Cellular Frequency Band Plan

824

Uplink 

(MHz)

Downlink 

(MHz)

869

825

870

835

880

845

890

846.5

891.5

849

894

B’

A’

B

A

A”

UL 825-835

DL 870-880

UL 824-825

DL 869-870

UL 835-845

DL 880-890

UL 845-846.5

DL 890-891.5

UL 846.5-849

DL 891.5-894

806

821

851

866

SMR 800

iDEN

UL 806-821

DL 851-866

SM800

UL 821-824

DL 866-869

SMR 900

UL 896-901

DL 935-940

896

901

935

940

794

806

764

776

Public
Safety

UL 794-806

DL 764-776

PCS Frequency Band Plan

Uplink In MHz

Downlink In 

MHz

1850

1930

1865

1870

1885

1890

1895

1910

1945

1950

1965

1970

1975

1990

A Full

A1

A2

A3

A4

A5

D Full

B Full

B1

B2

B3

B4

B5

E Full

F Full

C Full

C1

C2

C3

C4

C5

C6

C7

C9

UL 1850-1865

DL 1930-1945

UL 1865-1870
DL 1945-1950

UL 1870-1885

DL 1950-1965

UL 1885-1890

DL 1965-1970

UL 1890-1895

DL 1970-1975

UL 1895-1910

DL 1975-1990

UL 1895-1902.5

DL 1975-1982.5

UL 1902.5-1910

DL 1982.5-1990

UL 1895-1900

DL 1975-1980

UL 1900-1905

DL 1980-1985

UL 1905-1910

DL 1985-1990

UL 1895-1897.5

DL 1975-1977.5
UL 1897.5-1900

DL 1977.5-1980

UL 1900-1902.5
DL 1980-1982.5

UL 1902.5-1905
DL 1982.5-1985

C8

UL 1870-1877.5

DL 1950-1957.5

UL 1877.5-1885

DL 1957.5-1965

UL 1850-1857.5

DL 1930-1937.5

UL 1857.5-1865

DL 1937.5-1945

UL 1870-1875

DL 1950-1955

UL 1875-1880

DL 1955-1960

UL 1880-1885

DL 1960-1965

UL 1850-1855

DL 1930-1935

UL 1855-1860

DL 1935-1940

UL 1860-1865

DL 1940-1945

C11

C10

B6

B7

B9

B8

B11

B10

A6 A7

A9

A8

A11

A10

D1

D2

E1

E2

F1

F2

UL 1905-1907.5
DL 1985-1987.5
UL 1907.5-1910
DL 1987.5-1990

UL 1870-1872.5

DL 1950-1952.5
UL 1872.5-1875
DL 1952.5-1955

UL 1875-1877.5
DL 1955-1957.5

UL 1877.5-1880
DL 1957.5-1960

UL 1880-1882.5
DL 1960-1962.5
UL 1882.5-1885
DL 1962.5-1965

UL 1850-1852.5

DL 1930-1932.5
UL 1852.5-1855

DL 1932.5-1935

UL 1855-1857.5
DL 1935-1937.5

UL 1857.5-1860

DL 1937.5-1940

UL 1860-1862.5

DL 1940-1942.5

UL 1862.5-1865

DL 1942.5-1945

UL 1885-1887.5
DL 1965-1967.5

UL 1887.5-1890
DL 1967.5-1970

UL 1890-1892.5

DL 1970-1972.5
UL 1892.5-1895

DL 1972.5-1975

UL 1865-1867.5

DL 1945-1947.5
UL 1867.5-1870

DL 1947.5-1950

Содержание CSI-DSP85-252-C

Страница 1: ...CSI DSP85 252 C P CSI DSP85I 255 C P Installation Manual...

Страница 2: ...rations 10 Mounting the Digital Repeater 12 Optional Accessories 13 Circuit Operational Description 13 Important Installation Notes 13 Functional Block Diagram 14 Mechanical Specifications 15 AC Power...

Страница 3: ...results that may be obtained from the products described herein or the infringement by such products of any proprietary rights of any persons Use or application of such information or state ments is...

Страница 4: ...ermine the unit s adaptability to various field applications The following pages describe the Cellular and PCS band plans as well as the convention CSI uses to identify and store the files that make u...

Страница 5: ...80 UL 1900 1905 DL 1980 1985 UL 1905 1910 DL 1985 1990 UL 1895 1897 5 DL 1975 1977 5 UL 1897 5 1900 DL 1977 5 1980 UL 1900 1902 5 DL 1980 1982 5 UL 1902 5 1905 DL 1982 5 1985 C8 UL 1870 1877 5 DL 1950...

Страница 6: ...ons 7 Note Filter file names will be from six to twelve characters long Each character position in the filter file name is used to define the characteristics of the filter as shown above All frequenci...

Страница 7: ...mation LED Indicator Automatic safety precautions are built into the amplifier system In the case of a catastrophic system event a shutdown circuit is incorporated that will disable all emissions shou...

Страница 8: ...rial cable because of an unusual connector configuration In the vast majority of cases this information will not be needed Local Communication Interface Ports To allow monitoring and control the repea...

Страница 9: ...erwise reduced or eliminated without expensive and possibly prohibitive measures In these cases it may not be practical to use the repeater for providing coverage to these sites Selection of external...

Страница 10: ...29 dBm 65 dB 41 5 dBm 80 dB 28 2 dBm 64 dB 40 6 dBm 79 dB 27 4 dBm 63 dB 39 7 dBm 78 dB 26 6 dBm 62 dB 38 8 dBm 77 dB 25 8 dBm 61 dB 37 9 dBm 76 dB 25 dBm 60 dB 37 dBm 75 dB 24 4 dBm 59 dB 36 2 dBm 74...

Страница 11: ...kets as shown in the drawing to the right Wall Mounting 19 Relay Rack Mounting Mount the repeater as shown and secure front panel with screws Note the CSI digital repeaters must be supported in the 19...

Страница 12: ...r CSI AY 1 85 1 99 10 Battery backup 2 hr Single band Cellular model number CSI AY 806 960 14 1 hour dual band model number CS48 985 600 Inside Omnidirectional Antenna Quad band model number CSI AO 70...

Страница 13: ...14 Functional Block Diagram...

Страница 14: ...Hz Weight 31 0 lbs 14 1 kg Thermal Management Fan Cooled Surface Coating Powder Coat AC Current 3 2 Amps 120 VAC 1 7 Amps 230 VAC Repeater Size Height 5 25 in 3RU Width 19 00 in Depth 20 00 in Heat Ou...

Страница 15: ...GE W CDMA CDMA2000 CDMA RHO 0 98 min CDMA2000 1x EVD0 Spurious Emissions Applicable Documents FCC 13 dBm max Per FCC part 2 22 24 Industry Canada 13 dBm max Propagation Delay 2 5 usec Input VSWR Typ 2...

Страница 16: ...17 Mechanical Drawing DONER INDOOR SERVER OUTDOOR ETHERNET USB STATUS 2 STATUS 1 2 1 7 6 3 5...

Страница 17: ...a host that has a static IP Select Use the following IP Address and enter the IP Address as follows 192 168 1 x where x any number from 2 to 254 inclusive other than 100 The subnet mask is 255 255 255...

Страница 18: ...with software version 2 2 4 or prior only letters numbers and underscores are acceptable nomenclature In units with software version 2 3 0 and up Underscores are not accept able however hyphens are ac...

Страница 19: ...layed To change gain settings the user will select the Uplink only or Uplink and downlink radio buttons The user then inputs the gain value desired Gain values from 53 5 dB to 85 0 dB may be selected...

Страница 20: ...deselect them before programming To aid the user a clear all button is provided on the PCS band and will deselect all band and sub bands simulta neously Pressing the Program button will complete the s...

Страница 21: ...Configuration If the repeater includes a USB modem kit click on Remote Network in the navigation box and the screen below is displayed Highlight the carrier on whose network the repeater and modem wi...

Страница 22: ...Contact CSI for updates and instructions The user may clear LED indicators alarms and the Event Log by clicking the Clear Log button System Health Install Upload If required in your market visit the S...

Страница 23: ...ters numbers hyphens are the only acceptable nomenclature for the Location field and hyphens may not be used as the first or last character If a reboot of the repeater becomes necessary click on the R...

Страница 24: ...Log Configuration E mail Configuration page allows the user to enter up to five E mail addresses to which the repeater can send specified alarm messages when the repeater is connected via ethernet or...

Страница 25: ...s not the same as shown in figure 1 a null modem adapter optional as shown in Figure 2 may also be required Figure 1 Figure 2 To end the session exit the browser the user will be automatically logged...

Страница 26: ...llowing screen is displayed Select the Serial radio button and press OK as shown below Note It may be necessary in the System Properties section of the control panel using Device Manager to determine...

Страница 27: ...nd The user name for changing the PCS band is pcsband The password for both bands is csi1234 After entering the password and pressing return the TMI main menu will appear Note by default the Set Param...

Страница 28: ...mple from the Link Configuration menu on the previous page selecting 1 Adjust Gain will display the menu shown below After selecting option 1 downlink the current user gain is displayed and the option...

Страница 29: ...tablish a link In other words the IP addresses of both the computer used and the repeater must use the same group of IP address number sets For example the repeater ships with the default IP address o...

Страница 30: ...res an independent login To make changes to the cellular band the default user name is cellband The default user name for changing the PCS band is pcsband In the field after the prompt type the user n...

Страница 31: ...card to become fully functional contact the service provider In addition an IP address must be obtained and entered into the repeater Once the modem has been installed and activated it can be accessed...

Страница 32: ...ayed Select Use the following IP address and enter 192 168 1 2 The subnet mask should automatically populate to 255 255 255 0 Scroll down and highlight Internet Protocol TCP IP and click on the Proper...

Страница 33: ...nalyzer will need to be equipped with a whip antenna for this Resolution Bandwidth RBW should be set at 200 kHz for GSM and 1 MHz for CDMA If you cannot select these values the closest available value...

Страница 34: ...paid by Buyer The provisions of this warranty shall be appli cable with respect to any product which Seller replaces pursuant to it SELLER MAKES NO WARRANTY EXPRESS OR IMPLIED OTHER THAN AS SPECIFICAL...

Страница 35: ...n Interface Ports 9 Local Network 19 Log Configuration 26 M Manual Gain Control 16 Maximum RF input Power 16 Modem Interface 32 Modem Interface Remote Ac cess with login 32 Monitoring Alarms 9 N Noise...

Страница 36: ...37 Notes...

Страница 37: ...38 Notes...

Страница 38: ...39 Notes...

Страница 39: ...960 1049 001 rev 002...

Отзывы: