Section BXM‐161‐4HE‐20A

030‐101374 Rev. A

R

2

1211IARA

Figure 2.

Isometric Open View of Boxer‐16 Cabinet

Side lift ear with

2” hole

(not for permanent

mounting)

Door sensor

Door sealing

gasket

ESD jack

Controller Card

(for fan, ‐48VDC

connections, see

Figure 13)

Fins of Heat

Exchanger

Interior  Fans

(Fan B

connector)

Ground

Posts

Holes to

mount 16

RU's of

equipment in

rack channel

Convenience

Outlet

Outside air fans

in heat exchanger

compartment

(use Fan A
connector)

AC duplex

outlet (inside)

2‐point door latch

Wind

latch

Slotted groove in channel

adjustment bracket

Liquid tight fitting in

access hole for heat

exchanger wires

Heat

Exchanger

Compartment

(unlocks with

Phillips screw

from inside

the cabinet)

S

‐48VDC powered

S

Low noise level

S

Compact size (24” W x 33” H x 27.75” D, approx.)

S

Weather‐tight cabinet

S

Screened vents resist insect intrusion

S

Rear‐access panel

S

Interior area provides 16 RUs of 19” rack mounting space

S

Easily adjustable rack channels

S

Ample space for tie‐downs and cable management

S

Door security via:

S

Single handle with 2‐point latch

S

a locking, hex, cup‐washer screw

S

a hole for a padlock

S

Numerous ground/bond posts on interior ground plate

S

Knock‐outs at cabinet bottom accept a variety of cable,
conduit, and connector sizes and types

S

Interior sliding wind latch

Содержание Boxer BXM1619-4HE

Страница 1: ...onic equipment Up to 16 vertical RUs 28 of 19 inch wide inter nal rack space is available to house Network equipment such as but not limited to multiplexers copper bonding solutions Ethernet switches...

Страница 2: ...nt bracket Liquid tight fitting in access hole for heat exchanger wires Heat Exchanger Compartment unlocks with Phillips screw from inside the cabinet S 48VDC powered S Low noise level S Compact size...

Страница 3: ...commodate a variety of cable fitting or conduit sizes and types 2 1 2 1 Large Cabinet Door A full size locking door provides ample technician and equip ment access to the interior of the cabinet and a...

Страница 4: ...gure 7 Mounting Brackets for Wall H Frame Mounting Top Exterior Mounting Bracket note the keyholes Bottom Exterior Mounting Bracket note the 5 slots at the bottom The brackets are factory installed on...

Страница 5: ...nnel mounting bracket 1 of 7 position holes Loosen nuts lift and slide rack channel to desired position Rack Channel 2 2 1 Internal 19 Rack Channels Two adjustable rack channels see Figure 10 inside t...

Страница 6: ...5 External Air Fans FAN A Connector Two factory installed always on fans shown in Figure 12 to circulate cooler exterior air up through the heat exchanger are located under the cover for the heat exch...

Страница 7: ...binet Figure 14 close to the front door A ground plate is provided that contains eight sets of ground posts and one copper ground lug for cable and chassis earth ground Bond equipment cables to the gr...

Страница 8: ...lies not provided are required to mount the Boxer 16 cabinet Door Opening Locking Tools V 7 16 can wrench or 216 tool V Padlock optional Knock Out Removal Tools V Hammer V Punch V Pliers Cabinet Mount...

Страница 9: ...he mounting steps All knock outs should be knocked out from the inside of the cabinet except for the small 0 575 knock outs which are to be knocked out from the outside of the cabinet and except for t...

Страница 10: ...inet and clean the site Close the Boxer 16 door and lock it using a can wrench or 216 tool and an op tional padlock Pick up any tools and materials at the installation site and clean the site of any t...

Страница 11: ...und rod or wire 6 AWG must enter the cabinet and be connected to the ground lug located on the interi or ground plate Make all ground connections prior to any telecommunications cable connections Grou...

Страница 12: ...nnecting 48VDC Fan Power Follow the steps below to connect 48VDC fan power from a 48VDC power source to the Euro connector in the Controller Figure 20 Euro Connectors for Field Connections Pull off co...

Страница 13: ...agraph 3 10 if it is also desired to wire Boxer 16 s GFI convenience outlet 6 Fish or route wires Fish or route the AC wires from the power source through the conduit to the Boxer 16 cabinet routing t...

Страница 14: ...le connections at the inside rear of the cabinet The panel is secured with hex nut in cup screws 3 14 Connecting Communication Cables The types of communication cables used and their connector types i...

Страница 15: ...mbly CAUTION To avoid electrical shock turn off any DC or AC power feeds to the panel before removing or replacing the controller card 5 1 Replacing the Controller Card The Controller Card cannot be f...

Страница 16: ...tor 14 Apply power and test If not already installed re install the fuse in the controller card and apply power to the cabinet Verify the fans are working properly 5 3 Replacing the Inside Air Fans Fa...

Страница 17: ...he mounting bracket Connect the wires into their proper positions in the new switch Insert the new door sensor assembly into its mount ing bracket from the rear side so the door sensor button protrude...

Страница 18: ...g 16RU 19 rack AC GFI out lets screw down rear access panel Other Boxer Cabinets A90 BXM3019 NAF Boxer 800W 48VDC fan cooled 30 RU 19 rack AC GFI outlets screw down rear access panel A90 BXM2019 4HE B...

Страница 19: ...101374 Rev A R 19 1211IARA Appendix A Product Views Figure 24 Bottom View of Boxer 16 Cabinet Showing Dimensions and Knock outs Mounting lift brackets fan cooling and door handle not shown For mountin...

Страница 20: ...Section BXM 161 4HE 20A 030 101374 Rev A R 20 1211IARA Figure 25 Front Exterior View of Boxer 16 Cabinet 24 0 33 0 24 5 41 0 39 0 Rear View Panel On...

Страница 21: ...Section BXM 161 4HE 20A 030 101374 Rev A R 21 1211IARA Figure 26 Right Side Exterior View of Boxer 16 Cabinet 33 0 18 05 20 60 28 10 41 0...

Отзывы: