Section AIS‐RM3‐20B
030‐101806 Rev. A
R
1310IBRA
15
5.4
Summary Report
The
Summary Report
menu, shown in Figure 41, displays an in
formation summary of the AISG‐RM3 controller and enables
downloading of both the summary report and the system access
log report. These two functions are executed by selecting their
buttons near the top right corner of the screen.
System Setting
Action*
Information Recorded
Description
SET_NET
Current IP, Gateway, Sub
Network mask
Network Setting
SET_SCAN_
LENGTH
Current scan length setting
for device scan
Set Scan Length
SET_POWER
Current DC 12V/24V setting
and power mode
Power Setting
SET_SYS_TIME Current system date and
time setting
System Time Setting
REBOOT
AISG‐RM3 is rebooted
System Account
Action*
Information Recorded
Description
ADD_USER
Which user account is ad
ded
Add User Account
DELETE_USER
Which user account is de
leted
Delete User Account
Device Information Initialization
Action*
Information Recorded
Description
SCAN
A scan process is initiated.
ADD_DEV
Vendor code and serial no.
of added device
Add Device
SAVE_DEV
A save process is initiated for
storing device information to
AISG‐RM3.
RESET_DEV
Sector ID
Reset Device. Device identi
fied by Sector ID is reset
Device & Antenna Data Setting
Action*
Information Recorded
Description
SAVE_
SELECTED
Sector ID
Save Antenna Data. Selected
antenna data of the device
identified by Sector ID is saved
CONFIGURE_
MODEL
Sector ID
Save Antenna Model. Antenna
model of the device identified
by Sector ID is changed.
CALIBRATE
Sector ID
RET Calibrate. Device identi
fied by Sector ID is calibrated
SET_TILT
Sector ID, tilt value
Set RET Tilt
SET_GAIN
Sector ID, gain value
Set TMA Gain
SET_MODE
Sector ID, mode
Set TMA Mode
*Note: The
key word in the Action column is used in the log to represent the recorded action. Information re
lated to an action in the Information Recorded column is also recorded in the log.
Table 13. TMA Device Data / Fields
Summary Report.
The summary report includes the detailed in
formation on each device, the site information, and system settings.
Figure 41. Summary Report and Access Log
"
"
Click on the Download Report button (see the solid red arrow in
Figure 41) to store a copy of the summary report in html format.
Click on the Download Access Log button (indicated by the
stripped blue arrow in Figure 41) to download a copy of the sys
tem access history in text format. The access log records the
time, the user, and the type of action that has taken place. Only
actions that pertain to system setting changes, user account ad
dition and deletion, and device setting changes are recorded.
The actions and the corresponding information recorded in the
log are described in Table 13.
6.
MANAGING ANTENNA CONFIGURATIONS
The
Antenna Config File
menu is used to manage antenna con
figuration files for RET antenna model configurations. The
antenna configuration file data establishes the relationship
between the movement of a RET drive system and the beam tilt
position of the antenna. If the model of an antenna connected
to a RET device is not in the AISG‐RM3 controller, then its con
figuration file must be uploaded.
Figure 42. Antenna Configuration File Screen
6.1
Adding a Vendor
A vendor ’s name must exist in the Vendor dropdown list before
uploading one of its antenna model configuration files. To add
a new vendor, click on the Add button (see the red arrow in
Figure 42). The window below appears.
This window asks for the two‐character vendor code assigned by
AISG for use in identifying a product’s vendor. The combination