Summary Report

The 

Summary Report

 menu, shown in Figure 41, displays an in­

formation summary of the AISG‐RM3 controller and enables
downloading of both the summary report and the system access
log report. These two functions are executed by selecting their
buttons near the top right corner of the screen.

System Setting

Action*

Information Recorded

Description

SET_NET

Current IP, Gateway, Sub­
Network mask

Network Setting

SET_SCAN_
LENGTH

Current scan length setting
for device scan

Set Scan Length

SET_POWER

Current DC 12V/24V setting
and power mode

Power Setting

SET_SYS_TIME Current system date and

time setting

System Time Setting

REBOOT

AISG‐RM3 is rebooted

System Account

Action*

Information Recorded

Description

ADD_USER

Which user account is ad­
ded

Add User Account

DELETE_USER

Which user account is de­
leted

Delete User Account

Device Information Initialization

Action*

Information Recorded

Description

SCAN

A scan process is initiated.

ADD_DEV

Vendor code and serial no.
of added device

Add Device

SAVE_DEV

A save process is initiated for
storing device information to
AISG‐RM3.

RESET_DEV

Sector ID

Reset Device. Device identi­
fied by Sector ID is reset

Device & Antenna Data Setting

Action*

Information Recorded

Description

SAVE_
SELECTED

Sector ID

Save Antenna Data. Selected
antenna data of the device
identified by Sector ID is saved

CONFIGURE_
MODEL

Sector ID

Save Antenna Model. Antenna
model of the device identified
by Sector ID is changed.

CALIBRATE

Sector ID

RET Calibrate. Device identi­
fied by Sector ID is calibrated

SET_TILT

Sector ID, tilt value

Set RET Tilt

SET_GAIN

Sector ID, gain value

Set TMA Gain

SET_MODE

Sector ID, mode

Set TMA Mode

*Note: The 

key word in the Action column is used in the log to represent the recorded action. Information re­

lated to an action in the Information Recorded column is also recorded in the log.

Table 13.    TMA Device Data / Fields

Summary Report. 

The summary report includes the detailed in­

formation on each device, the site information, and system settings.

Figure 41. Summary Report and Access Log

"

"

Click on the Download Report button (see the solid red arrow in
Figure 41) to store a copy of the summary report in html format.

Click on the Download Access Log button (indicated by the
stripped blue arrow in Figure 41) to download a copy of the sys­
tem access history in text format. The access log records the
time, the user, and the type of action that has taken place. Only
actions that pertain to system setting changes, user account ad­
dition and deletion, and device setting changes are recorded.
The actions and the corresponding information recorded in the
log are described in Table 13.

6.

MANAGING ANTENNA CONFIGURATIONS

The 

Antenna Config File

 menu is used to manage antenna con­

figuration files for RET antenna model configurations. The
antenna configuration file data establishes the relationship
between the movement of a RET drive system and the beam tilt
position of the antenna. If the model of an antenna connected
to a RET device is not in the AISG‐RM3 controller, then its con­
figuration file must be uploaded.

Figure 42. Antenna Configuration File Screen

6.1

Adding a Vendor

A vendor ’s name must exist in the Vendor drop­down list before
uploading one of its antenna model configuration files. To add
a new vendor, click on the Add button (see the red arrow in
Figure 42). The window below appears.

This window asks for the two‐character vendor code assigned by
AISG for use in identifying a product’s vendor. The combination

Содержание AISG-RM3

Страница 1: ...son will be stated here This document reflects the Issue B equipment which accepts an input power supply range of 48VDC to 24VDC and uses con tact relays as alarm outputs Figure 1 AISG RM3 AISG Contro...

Страница 2: ...a reset button and three LEDs as shown in Table 1 and Table 4 below and ex plained in the paragraphs that follow LED Color State Status Description ALM alarm Red Steady AISG RM3 cannot ping default g...

Страница 3: ...C Normally Closed relay output Contact Capacity AC 125V 0 5A DC 24V 1A N O Normally Open relay output COMM Common N A GND Ground of I O channels Ground Table 3 Alarm Connector Pin outs 2 2 5 Ethernet...

Страница 4: ...ent Any in structions or information contained herein is subordinate to local codes operating procedures or practices CAUTION Improper grounding could be service affecting and cause service interrupti...

Страница 5: ...f the controller has been preset to 192 168 0 30 Enter this IP address for first time access It can be changed later The browser should display the Login page as shown in Figure 7 Figure 7 Login Scree...

Страница 6: ...enna Config File _ Summary Report _ Site Information _ Logout _ System Setting 4 1 Configure the System Settings Click on the System Setting tab as shown in Figure 11 to open the System Setting menu T...

Страница 7: ...age and power supply mode provided to the connected AISG devices can be changed Change the settings per company practice refer ring to Table 6 as needed then click on the Set button to apply the chang...

Страница 8: ...before triggering the alarm output This helps to remove any spurious non real alarm conditions 4 2 Manage User Accounts Click on the System Account tab on the main menu to open the user list accounts...

Страница 9: ...ized device is listed in the RET or TMA device list section panel according to its device type Devices are sorted by Sector ID in ascending order Scanning retrieves information previously stored in ea...

Страница 10: ...you are adding The Vendor Code is optional Click on the Add button to initiate the process If the process is successful the Device List will be updated Save the device information before moving on 5...

Страница 11: ...lf of a selected device screen Figure 31 shows detailed information about the an tenna connected to the selected AISG device Table 10 explains the fields and options in the Antenna Data section or pan...

Страница 12: ...lowed electrical down tilt range of the selected an tenna model Current Tilt Current electrical tilt Tilt value must be in the Min Tilt Max Tilt range If the tilt value cannot be retrieved the data va...

Страница 13: ...ISG version supported by the TMA device Figure 38 Viewing a Specific TMA Shown in Device List The fields in the selected TMA Device panel are listed in Table 12 Field Name Description Constraint Optio...

Страница 14: ...ation window below is displayed Click on the OK button to initiate the process of chan ging the TMA gain After the process is done close the message window 5 2 3 4 Get Gain Click on the Get Gain butto...

Страница 15: ...TMA Gain SET_MODE Sector ID mode Set TMA Mode Note The key word in the Action column is used in the log to represent the recorded action Information re lated to an action in the Information Recorded c...

Страница 16: ...n one vendor code the vendor code is also shown after the vendor name Select the vendor name with the right vendor code to upload the configuration file The vendor code must match the vendor code on t...

Страница 17: ...the AISG RM3 controller Set the terminal connection settings to Baud Rate 9600 Stop bits 1 Data bits 8 No Parity 7 2 Using Console Commands Once connection with the AISG RM3 controller is established...

Страница 18: ...ke effect 15 Set System Date Time Changes the system UTC date and time 16 Set 12v 24v Power Setting Switches 12V 24V DC on or off The default is N which represents off Table 16 Command Display Numbers...

Страница 19: ...rmware Once finished perform a manual reboot of the controller 3 Refresh the browser to reload the user interface you will find the changed upgraded firmware 9 ERROR ALARM CODES MESSAGES The following...

Страница 20: ...n between the AISG RM3 system and the device 0x53 No Responding X Lost connection between the AISG RM3 system and the device 0x54 Function Fail Unexpected result from the AISG RM3 system 0x59 Timeout...

Страница 21: ...ling programs and local codes and per state statutes 12 SPECIFICATIONS 12 1 Electrical Specifications A Power supply input DC 24V max 3 2A or 48V max 1 6A B Power supply to AISG devices 24V max 2 0 A...

Страница 22: ...Amplifier LTE Long Term Evolution mA milliAmps MHz Megahertz PDU Power Distribution Unit RES Receiver Enhancement System RF Radio Frequency Rx Receive TMA Tower Mounted Amplifier Tx Transmit V Volts...