Section BXM‐301‐10H‐20A

030‐101901 Rev. A

R

2

1608IARA

Figure 2.

Isometric Open View of Boxer‐30 Cabinet

Side lift ear with

2” hole

(not for permanent

mounting)

Door sensor

switch

Slotted groove in channel

adjustment bracket

Ground posts

Holes in rack

channel to mount

equipment

Convenience

outlet

3‐point

door latch

Power cord

access for

exchanger

electronics

Air exhaust

hole

Documentation

tray

AC duplex outlets

(inside)

Heat exchanger

Air intake

holes

Knock‐out

Wind latch

Top and bottom mounting brackets not shown

ÖÖÖ

ÖÖÖ

ÖÖÖ

ÖÖÖ

ÖÖÖ

ÖÖÖ

ÖÖÖ

ware must be capable of supporting the weight of the Boxer‐30
cabinet plus the weight of any equipment mounted in it. The
Boxer‐30 cabinet is typically located at the customer premises
but can be located anywhere a weather‐tight, outdoor cabinet
is required.

1.5

Product Features

Each Boxer‐30 cabinet comes fully assembled, pre‐wired,
tested, and ready for field‐provided customer equipment
installation, and includes the following features and capabili­
ties.

S

NEMA 4 compliant

S

Weather‐tight cabinet

S

Actively cooled with heat exchanger

S

Dissipates up to 1800 watts

S

‐48VDC powered

S

Thermostat controlled heat exchanger

S

Rear‐access panel

S

Interior area provides 30 RUs of 19” rack mounting space

Содержание A90-BXM3019-10HE

Страница 1: ...3 Product Purpose and Description Boxer 30 is an actively cooled NEMA 4 outdoor cabinet that can house and protect a wide range of electronic equipment Up to 30 vertical RUs 52 5 of 19 inch wide inter...

Страница 2: ...t shown ware must be capable of supporting the weight of the Boxer 30 cabinet plus the weight of any equipment mounted in it The Boxer 30 cabinet is typically located at the customer premises but can...

Страница 3: ...nting brackets at the top and bottom of the cabinet facilitate wall and H frame mount ing The bottom floor of the main cabinet contains numerous differently sized intact knock outs Paragraph 2 1 2 6 t...

Страница 4: ...kets one at the top and one at the bottom of the cabinet come factory installed Figure 7 Mounting Brackets for Wall H Frame Mounting Top Exterior Mounting Bracket note the keyholes Bottom Exterior Mou...

Страница 5: ...moved forward 2 or backward 3 if a few additional inches of equipment depth is needed at either the front or back of the channel Seven slots are provided for seven channel positions see Figure 2 Each...

Страница 6: ...internal temperature reaches 70_F 21 1_C and will reach full speed when the internal tem perature reaches 80_F 26 7_C The external heat exchanger fan will turn on at 10 speed when the external temper...

Страница 7: ...ro vided E This product should be operated only from the type of power source indicated on the marking label F Never push objects of any kind into this product through cabi net slots as they may touch...

Страница 8: ...ut type and regardless of the order of the mounting steps All knock outs should be knocked out from the inside of the cabinet except for the small 0 575 knock outs which are to be knocked out from the...

Страница 9: ...ttom mounting bracket and H frame rail Verify the cabinet is in the proper horizontal position make any needed ad justments then securely tighten all mounting hardware 6 Test installation firmness Tes...

Страница 10: ...cabinet then marking the mounting hole loca tions or by measuring without lifting the equipment as a template Two of the mounting bracket holes are 16 apart on centers to facilitate mounting on standa...

Страница 11: ...met or liquid tight fitting Install ei ther conduit and an appropriate and liquid tight fitting or a rubber grommet in the knock out hole 4 Route ground wire through knock out hole Run the ap proved g...

Страница 12: ...applied in Para graph 3 12 3 Verify the knock outs are removed Perform the steps in Paragraph 3 5 to remove any appropriate cabinet hole knock out s and to install an appropriate fitting or grom met...

Страница 13: ...laced inside the cabinet does not exceed the maximum weight requirement for the mounting structure surface and type 4 Determine the best mounting location for each piece of equipment for maximum capac...

Страница 14: ...ble 2 for the replacement heat exchanger part number Figure 20 Field Replacement of Heat Exchanger Location of top two nuts Location of four lower bolts Heat exchanger Hole for AC power cord 1 4 20 1...

Страница 15: ...er from Westell Once an RMA number is obtained return the defec tive unit freight prepaid and a brief problem description to Voice 630 375 4457 email rgmdept westell com Replacements will be shipped i...

Страница 16: ...ncy Specifications The Boxer 30 cabinet is designed to meet the following regula tory safety or environmental specifications or requirements S NEMA 4 compliant 9 APPENDIX A PRODUCT VIEWS Figure 21 Bot...

Страница 17: ...Section BXM 301 10H 20A 030 101901 Rev A R 17 1608IARA Figure 22 Front Exterior View of Boxer 30 Cabinet 35 4 60 6 24 4 24 0 56 8 17 8 2 0 18 4 Top and bottom mounting brackets not shown...

Страница 18: ...Section BXM 301 10H 20A 030 101901 Rev A R 18 1608IARA 18 3 21 3 29 6 60 6 56 8 Figure 23 Exterior Right Side View of Boxer 30 Cabinet Top and bottom mounting brackets not shown...

Отзывы: