background image

Section 28M-K2Q-BK0-20C

030-101562 Rev. B

R

0505ICRB

3

2.4

Making Ground and Power Connections

2.4.1

Ground. 

Ground connections are made to the ground lug

located in the top right-hand corner of the kit plate. This will provide
a common ground for the mounting. All grounding practices apply
that would apply for mounting a single 28MA204AK assembly. For
applications requiring chassis ground to be connected to circuit
ground, an optional green wire strap is provided for installation be-
tween the GND lug and the GND position of the 28MA204AK TB1
power terminal block.

- CAUTION -

Never apply power until all installer connections are made.

2.4.2

Power. 

 Power connections, if required, are made to the top

of the 28MA204AK mounting. Refer to the enclosed 28MA204AK
mounting practice for appropriate power connections to the mount-
ing.

2.5

Making Facility-Side Wiring Connections

Facility-side wiring connections are made to the top half of the 66-
type terminal block. Refer to Figure 3 and Table 1.

2.6

Making Customer-Side Wiring Connections

Customer connections are typically made to the 66-type block, but
also can be made to the 8-pin RJ48 jacks on the mounting.

S

66-Block.

 If extending the RJ48 jack beyond the mounting, use

the bottom half of the 66-block, as shown in Figure 3, and refer
to Table 2 for correct circuit, wire, and terminal designations.
The block is factory pre-wired to four RJ48 pigtails, which are
provided and shipped factory-inserted into the four RJ48 jacks
at the bottom of the mounting

The 66 block provides both

RJ48C (for HDSL/NIU applications) and RJ48S (for DDS/
DST) connections. Always insure the jack switches at the
bottom of the mounting are set to the correct position per  the
connections to the 66 block for RJ48C or RJ48S applications.

S

RJ48 Jacks.

 Customer connections also can be made to the

RJ48 jacks located at the bottom of the mounting, as shown in
Figure 3. This is done by removing the RJ48 pigtails (provided
with the kit and pre-wired to the 66-block) and inserting custom-
er-supplied, separate, RJ48 cable plugs into the jacks. The
mounting also contains a jack switch for each jack, to set the jack
type to either RJ48C (for HDSL/NIU applications) or RJ48S
(for DDS/DST applications). The switches are factory preset to
the C" position. Insure  the jack switches (at the bottom of the
mounting) are set to the proper position for the application. See
the mounting practice for details.

2.7

Installing the Plug-in Modules

Consult the module practice when installing modules. Before instal-
ling any module, set any option switches to the desired positions.
Align the module with the mounting card guides above and below
the unit and fully-insert into the slot connector.

CAUTION - STATIC-SENSITIVE

This product and the plug-in product installed inside the assembly
may contain static-sensitive components! Follow proper electrostatic
discharge procedures to maintain personal and equipment safety.

3.

TESTING & TROUBLESHOOTING

The equipment should not be field repaired. If trouble occurs, check
that the CO power fuse is not blown and verify all installer connec-
tions, module connections, option switch settings, and that modules
have a positive connection with the shelf connectors. If trouble per-
sists, replace the suspect unit with another, optioned identically, and
retest. If the replacement operates correctly, the original may be
faulty and can be returned to Westell for repair or replacement
(Paragraph 5.2). These procedures are not designed to effect repairs

or modifications. Tests/repairs beyond those outlined herein or re-
placing a faulty unit are not recommended and may void a warranty.

CIRCUIT

COLOR

4 SLOT MOUNTING

66 BLOCK

white/blue

T

3

1

blue

R

4

white/orange

T1

5

orange

R1

6

white/green

T

9

2

green

R

10

white/brown

T1

11

brown

R1

12

white/blue

T

15

3

blue

R

16

white/orange

T1

17

orange

R1

18

white/green

T

21

4

green

R

22

white/brown

T1

23

brown

R1

24

Table 1.    Network-Side Wiring Chart

4 SLOT MOUNTING

CIRCUIT

COLOR

RJ48

PINOUT

RJ48C

HDSL/NIU

RJ48S

DDS/DST

66

BLOCK

white/blue

5

CT

unused

27

blue

4

CR

unused

28

1

white/orange

2

CT1

DTT

29

orange

1

CR1

DTR

30

white/green

8

unused

DRT

31

green

7

unused

DRR

32

white/blue

5

CT

unused

33

blue

4

CR

unused

34

2

white/orange

2

CT1

DTT

35

orange

1

CR1

DTR

36

white/green

8

unused

DRT

37

green

7

unused

DRR

38

white/blue

5

CT

unused

39

blue

4

CR

unused

40

3

white/orange

2

CT1

DTT

41

orange

1

CR1

DTR

42

white/green

8

unused

DRT

43

green

7

unused

DRR

44

white/blue

5

CT

unused

45

blue

4

CR

unused

46

4

white/orange

2

CT1

DTT

47

orange

1

CR1

DTR

48

white/green

8

unused

DRT

49

green

7

unused

DRR

50

Table 2.    Customer-Side Wiring Chart

4.

CUSTOMER & TECHNICAL SERVICES

If technical or customer assistance is required, contact Westell via
one of the following options:

Voice: (630) 898-2500
Voice: (800) 323-6883
email:

[email protected]

Visit the Westell internet site at http://

www.Westell.com.

5.

WARRANTY & REPAIRS

5.1

Warranty

. Westell warrants this product to be defect-free

at shipment time and to be fully functional for the time period speci-

Отзывы: