74
250050 R1
6.28. Finish Plenum Flashing Installation
To finish the plenum flashing installation:
1. Bolt the plenum flashing to the sidewall all the way around the bin.
a. Use 3/8” bin bolts, 3/8” fender washers (90010023), and 3/8” hex nuts (018913). (See ❷ in
2. Install self-drilling Tek screws (90100352) along flashing-to-flashing seams. (See ❸ in
and
for approximate spacing of the screws.)
Figure 40.
Attaching the Plenum Flashing to the Sidewall
2
3/8” BIN
BOLT
(all places)
3/8”
HEX NUT
018983
3/8” FENDER
WASHER
90010023
3
SELF DRILLING
TEK SCREW
90100352
(all places)
EASYDRY® WIDE-CORR CENTURION® GRAIN BIN – GRAIN BIN DRYER