Timer section 

Working mode 

Indicator 

Working mode 

Timer-1 

‘0’

non-working 

‘1~9’

  1-9 hours working   

Power%-1 

‘0’

no output

 

‘1~9’

10%~90% power 

100% power 

Timer-2 

‘0’

non-working 

‘1~9’

  1-9 hours working 

Power%-2 

‘0’

no output

 

‘1~9’

10%~90% power 

100% power 

Timer-3 

‘0’

non-working 

‘1~9’

  1-9 hours working 

Power%-3 

‘0’

no output

 

‘1~9’

10%~90% power 

100% power 

Timer-4 

‘0’

non-working 

‘1~9’

  1-9 hours working 

Power%-4 

‘0’

no output

 

‘1~9’

10%~90% power 

100% power 

Volt.adj. 

‘3~9’

30%~90% power, Limited power percentage of voltage control; 

100% power, no limitation. 

Temp.adj. 

‘3~9’

30%~90% power, Limited power percentage of temperature control; 

100% power, no limitation. 

Notes: 

1.

 

Limited power percentage of voltage control

 

When battery voltage changes, the actual operating power is limited, which is a linear increase or decrease. It operates as 
per the following formula:   
Actual  operating  power%  =  [(Battery  voltage-11.1V)/(12.0-11.1V)]*(setting  power%  of  current  timer  section  -  limited 
power%)+limited power %. 
Notes: When it is powered for the first time, the system identifies the voltage

18V as 12V system, and ≥18V as 24V 

system. The above formula is applicable for 12V system. If it is 24V system, 11.1v is changed into 22.2V and 12.0V into 
24.0V in the formula. When the battery voltage is lower than 11.1V or 22.2V, the formula is not applicable and the actual 
power is operated as per the limited power. And when the battery voltage is higher than 12V or 24V, the actual power is 
operated as per the setting power of current timer. 
2.

 

Limited power percentage of temperature control: 

The control theory for temperature change is the same as voltage change, with the formula changed into the following: 
Actual operating power% = [(current temperature-75

)/(85

-75

)]*(setting power% of current timer section - limited 

power%)+limited power %. 
Notes: The effective temperature range is 75

~85

. When it is lower than 75

, the actual power is operated as per the 

setting power of current timer section. And when it is higher than 85

, it is operated as per the limited power. 

3.    If the limited power percentage of voltage control or temperature control is more than current timer section, or there 
is no power percentage limitation of voltage and temperature, it operates as per the power of the current timer. 
4.    When percentage limitations of voltage and temperature work at the same time, the actual power operates as per the 
min. power calculated with the above formulas. 
5.    There  is  a period of  2-20  seconds  for  power  adjustment  each  time,  so  it  is  not  realized  at  once.  The  frequency  of 
PWM is 200Hz. 

          Parameters:

   

 

Item 

Parameters 

Input voltage range 

8 ~ 32VDC 

Max. input current 

9A 

Ambient temperature 

-40

~ +65

 

Storage temperature 

-40

~ +85

 

Humidity 

0 ~ 95% N.C. 

Enclosure 

IP30 

Altitude 

≤5000m 

Overall 

78mm x 49mm x 21mm 

Mounting 

69mm (vertical) 

Mounting hole 

Φ5 (R2.46) 

Terminal 

2.5mm

2

 

Net weight 

38g 

Version Number

V1.1 