14
4.4
Setting Operation
Dual timer function
The default night length is 10 hours.The controller can learn the night length
refering to the previous night so as to adapt to the different seasons.
However, it will take some time to learn it.
Notes: when the “OFF” time set at timer 2 is later than
local sunrise time, the controller will turn off the load
output at the sunrise time, which shows light control
first!
. Load Control Settings
1. Dusk to Dawn
When solar module voltage goes below the point of NTTV (Night Time
Threshold Voltage) at sunset, the controller will recognize the starting
voltage and turn on the load after 10 minutes
delay. When solar module
voltage goes above point of DTTV (Day Time Threshold Voltage), the solar
controller will recognize the starting voltage and turn off the load after 10
minutes delay.
2. Light ON + Timer
When solar module voltage goes below the point of NTTV (Night Time
Threshold Voltage) at sunset; the solar controller will recognize the starting
voltage and turn on the load after 10 minutes delay. The load will be on for
several hours which users set through LED digital tube. The controller has
dual timer function. Please refer to table 4-5 “Load Work Mode Setting”.
3. Test mode
This mode is the same as Dusk to Dawn. But there is no 10 minutes delay
when controller recognizes the starting voltage. When below the starting
voltage, the controller will turn on the load, if higher, it will turn off load.
The test mode makes it easy to check the system installation.
Light
ON
Light
OFF
Timer1
Number
of hours
Sunset
Midnight
Timer2
Number
of hours
Sunrise