Westbo VICTORIA 240 Скачать руководство пользователя страница 11

Westbo Victoria 240

Declaration of performance according regulation (EU) 305/2011 

No 2022-09-22

 

No.  Essential characteristics according to 

regulation (EU) 305/2011 

Statement by the manufacturer 

Unique identification code of the product-

type 

Freestanding roomheater 

Westbo Victoria 

100/240/Nobel

 

Intended use(s) 

Roomheater without hot water supply 

Trademark and contact address of the 

manufacturer 

Westbo of Sweden AB 

Industrigatan 8, S-333 75 Reftele, Sweden 

Contact address of the authorized 

representative 

Mattias Gunnarsson  

Westbo of Sweden AB 

Industrigatan 8, S-333 75 Reftele, Sweden 

System(s) of assessment and verification 

of constancy of performance of the 

construction product 

System 3 

Notified laboratory performed the 

determination of the product-type under 

system 3 and issued the test report 

Rhein-Ruhr Feuerstätten Prüfstelle GmbH, NB-No.: 

1625, test report no. RRF 

 40 19 3772-1 

Harmonized technical standard 

EN 13240:2001 /A2:2004/AC:2007 

Essential characteristics 

Performance 

Fire safety 

pass 

Reaction to fire 

A1 acc. EN 13501-1 

Distance to combustibles 

Minimum distances (d) to combustible materials 

Back (d) 

= 150 mm 

Side (d)  

= 450 mm  

Ceiling (d) 

= --- mm  

Floor (d) 

= 0 mm  

Window in the front (d

P

) = 800 mm 

Window in the side (ds) = 450 mm 

Risk of burning fuel falling out 

pass 

Cleanability 

pass 

Emission of combustion products 

pass  

CO = 0,08 % / = 1000 mg/m³ 

Flue gas temperature at nominal heat 

output in the measurement section 

Flue gas outlet temperature at nominal 

heat output 

 

245°C 

 

294°C 

Surface temperature 

pass 

Electrical safety 

not applicable 

Release of dangerous substances 

NPD 

Maximum operating pressure 

not applicable 

Mechanical resistance (to carry a 

chimney/flue) 

NPD 

Thermal output/Energy efficiency 

pass 

Nominal space heat output 

4,6 kW 

Nominal room heat output 

4,6 kW 

Nominal water heat output 

not applicable 

Efficiency 

ɳ

 = 81 % 

The performance of the product identified in points 1 and 2 is in conformity with the declared 

performance in point 8. This declaration of performance is issued under the sole responsibility of 

the manufacturer identified in point 4. 

 

Signed in responsibility of the manufacturer 

 

Mattias Gunnarsson 

 

 

Name 

 

 

 

Reftele,2022-09-22 

 

 

 

Place and date 

 

Sign / stamp 

 

Содержание VICTORIA 240

Страница 1: ...MANUAL AND INSTRUCTION WESTBO VICTORIA 240 Westbo of Sweden...

Страница 2: ...conditions for controlling combustion differ depending on the temperature in the burning chamber and the draught in the chimney This you will find out more after using the stove a couple of times A re...

Страница 3: ...e back or back top with collar Westbo Victoria can as standard only be connected backwards The collar is 125 mm in diameter For connection back top a special adapter must be purchased Connection to an...

Страница 4: ...e ash container Open the tray with the lever A and put the ash in the ash container NOTE The ash can contain embers several days after the fire Replace the front glass Remove the clips that hold the g...

Страница 5: ...nt brick 1 Start with the small side brick 2 Then remove the big side brick by lifting the roof brick that locks the big side brick 3 Take down the roof brick 4 Remove the angle brick Now it s easy to...

Страница 6: ...e Westbo of Sweden Westbo Victoria 240 Fire advise Air supply Westbo Victoria is equipped with one air control Emptying the ashes The ashtray is accessed by opening the lower door You can shake down t...

Страница 7: ...efore not get the correct temperature and it will not give any heat to the room This is of course uneconomic and could generate soot on the glass stove and chimney The environment also gets contaminat...

Страница 8: ...t 175 kg Material Cast iron Medeleffekt 4 6 kW Efficiency 81 CE approved EN 13240 A2 2004 AC 2006 Utg va 22 10 1306 471 591 397 373 339 A A B B 1398 224 376 120 31 135 244 14 50 20 268 40 A A 712 354...

Страница 9: ...Westbo of Sweden Westbo Victoria 240 Measure and technique Flamable wall Flamable wall Back connection Fire wall Fire wall Flamable wall Flamable wall Fire wall Fre wall...

Страница 10: ...ing to the instructions and will not be valid if any extreme or careless handling has occurred like overheating wrong fuel or too much wood etc Westbo of Sweden is obligated to provide new parts stove...

Страница 11: ...rformance Fire safety pass Reaction to fire A1 acc EN 13501 1 Distance to combustibles Minimum distances d to combustible materials Back d 150 mm Side d 450 mm Ceiling d mm Floor d 0 mm Window in the...

Страница 12: ...y efficiency class of the model A Direct heat output kW 4 6 Indirect heat output kW Energy efficiency index EEI 107 Useful energy efficiency at nominal heat output 81 0 Specific precautions that shall...

Страница 13: ...te briquettes no no n a n a n a n a n a n a n a n a n a Peat briquettes no no n a n a n a n a n a n a n a n a n a Blended fossil fuel briquettes no no n a n a n a n a n a n a n a n a n a Other fossil...

Страница 14: ...Westbo Victoria 240...

Страница 15: ...Westbo Victoria 240...