Operating Manual
Anderson Power Products® and Powerpole® is a registered trademark of Anderson Power Products, Inc.
correct. Follow the amateur radio standard used by the
RIGrunner.
DO NOT PLUG IN
without verifying that
RED + PLUS
and
BLACK – MINUS
is correct.
The far left connector is labeled the DCIN and is supplied
with a 40 amp fuse. The next connector is labeled “Master”
and is always ON. The master outlet is where you would
connect the primary radio, light or piece of equipment that
you would like to automatically control the nine switched
outlets. Plug in the equipment that you would like to be
switched ON and OFF, into switched outlets 1-9, starting
with the highest power connections to the left, and lower
power drain units to the right.
Notice the supplied fuse ratings next to the connector.
Typically 12V input amplifiers and 100 watt RF output
transceivers should be to the left, VHF radios next, and
smaller accessories to the right.
Multiple amplifiers and/or transceivers may be connected
to the RIGrunner. There is a 40 amp maximum that would
be exceeded if trying to transmit all connected units at
once. Most radios and amplifiers draw less than 3 amps in
receive, but require many more amps in transmit. Therefore,
the limiting factor is total current draw while transmitting.
To determine how many radios may be used to transmit at
one time, consult the radio manual for power consumption
specifications. In the event that the total current goes over
the 40 amp maximum, a fuse will blow or make an undersized
power supply unhappy. The RIGrunner and any equipment
plugged into the RIGrunner should go unharmed.
Using the proper fuses
The RIGrunner 4010S+ comes supplied with a range of
fuses installed. This assortment should be suitable for
most stations, but can be changed easily. Every RIGrunner
output is safe up to 40 amps, but the total allowable is also
40 amps. Note that the fuse on the Master outlet should
be sized to the lowest value that is possible to adequately
supply the equipment plugged into that outlet.
A fuse
MUST
have be in each position in use.
ANY
ATTEMPT TO BYPASS OR SHORT ACROSS THE
FUSES IS DANGEROUS AND VOIDS THE RIGRUNNER
WARRANTY
. Since the maximum available automotive fuse
is 40 amps, the RIGrunner will be protected as long as any
value ATC/ATO fuse is installed. Choose the correct fuse for
your equipment. Standard ATC/ATO automotive blade fuses
are used. These fuses are available in 10 values ranging
from 1 amp to 40 amps.
The DC input should have a fuse that is appropriate for
the power supply rating. If using a smaller power supply,
consider using a lower value fuse than the 40 amp value
supplied. Ideally all of the outlets should have a fuse that
is the next higher value above the maximum current draw
of the unit on that fuse. If using a power cord with a fuse,
match that value or go one or two values higher. Sizing each
fuse for each unit is desirable, but not absolutely necessary.
Having a higher value than the minimum will offer less
protection for that unit, too low a value and the fuse will blow
out prematurely.