West Mountain Radio RIGrunner 4004USB Скачать руководство пользователя страница 7

Operating Manual

4008

Overall Dimensions 

(maximum, w/o cables) 

1.4” H x 9” W x 3.0” D

Weight

0.65 lb.

Maximum total current

40 amps

Maximum single individual 

outlet current

40 amps (fuse 

protected)

4ICAS current rating  

(fuse limited)

37 amps

Precision comparator window 

points

11.5, 15.0V

Metering accuracy

better than 2% @  

25 deg. C

Audible alert SPL output

~60dB SPL @ 1 meter

Maximum voltage (meter 

circuit)

32 volts

Reverse polarity protection 

(meter circuit)

Yes

4008H

Overall Dimensions 

(maximum, w/o cables) 

1.4” H x 9.75” W x 

3.0” D

Weight

0.65 lb.

Voltage

Positive up to 48 VDC

Maximum total current

40 amps

Maximum single individual 

outlet current

40 amps (fuse 

protected)

4ICAS current rating  

(fuse limited)

37 amps

Precision comparator window 

points

11.5, 15.0V

4012

Overall Dimensions 

(maximum, w/o cables) 

1.4” H x 11.75” W x 

3.0” D

Weight

0.90 lb.

Maximum total current

40 amps

Maximum single individual 

outlet current

40 amps (fuse 

protected)

4ICAS current rating  

(fuse limited)

37 amps

Precision comparator window 

points

11.5, 15.0V

Metering accuracy

better than 2% @  

25 deg. C

Audible alert SPL output

~60dB SPL @ 1 meter

Maximum voltage (meter 

circuit)

32 volts

Reverse polarity protection 

(meter circuit)

Yes

Содержание RIGrunner 4004USB

Страница 1: ...City Drive Waukesha WI 53186 262 522 6503 sales westmountainradio com 2019 West Mountain Radio All rights reserved All trademarks are the property of their respective owners RIGrunner for models 4004...

Страница 2: ...mple do not put it on top of your amplifier or room heater or cover it with something It is recommended to not put it in the engine compartment of your car or directly on the floor of a car rain from...

Страница 3: ...ortment should be suitable for most stations but can be changed easily Every RIGrunner output is safe up to 40 amps but the total allowable is also 40 amps A fuse MUST be in each position in use ANY A...

Страница 4: ...ock and a frequency error This is a definite indication of a problem with the power source a bad connection an unregulated power supply a bad alternator or dying battery It is normal with most cars to...

Страница 5: ...ack Wire w Powerpole ends Powerpole Extension Cable 10 ft 58531 1084 12 Red Black Wire w Powerpole ends 15A Powerpole Connector 12 Pair 58257 1093 30A Powerpole Connector 12 Pair 58257 1095 45A Powerp...

Страница 6: ...rent 40 amps Maximum single individual outlet current 40 amps fuse protected 4ICAS current rating fuse limited 37 amps USB current charge 4A max for both ports 4006U Overall Dimensions maximum w o cab...

Страница 7: ...les 1 4 H x 9 75 W x 3 0 D Weight 0 65 lb Voltage Positive up to 48 VDC Maximum total current 40 amps Maximum single individual outlet current 40 amps fuse protected 4ICAS current rating fuse limited...

Страница 8: ...expense Repaired or replaced items are warranted for the remainder of the original warranty period You will be charged for repair or replacement of the RIGrunner or accessory made after the expiratio...