West Marine 14982045 Скачать руководство пользователя страница 6

Battery Chargers

1-877-571-2391

10

Battery Chargers

1-877-571-2391

11

 

IMPORTANT: 

If the battery is not fully charged (the battery charge gauge does not reach 100%) 

after 18 hours of continuous charging, the battery may have internal damage and will not accept 

a charge. After 18 hours, the charging process will automatically cut-off, the LCD screen will 

display the following (the digital readout shows “F04”, the battery charge gauge will indicate the 

battery’s current charge status, and the clamp icons and battery icon will light solid.):

  Disconnect the charger. Have the battery checked by a qualified technician.
  4. When the battery is completely charged, the unit automatically goes into float charge mode and 

the LCD screen displays the following:

  The digital display shows “FLO” to indicate that the unit is in float charge mode. The battery 

charge gauge points to 100%, indicating a full charge. The clamp icon and battery icon light 

solid,  and  the  arrow  icons  will  gradually  and  repeatedly  move  downward  to  the  battery  icon. 

In  this  mode,  the  unit  monitors  the  battery  voltage  and  charges  as  necessary  to  assure  the 

battery maintains full capacity. The unit remains in float charge mode as long as the charger is 

connected to the battery and plugged into a functioning AC outlet.

When disconnecting charger, disconnect the AC cord, remove clamp from vehicle chassis, and then 

remove clamp from battery terminal.

Checking the Battery Voltage

TO CHECK THE BATTERY VOLTAGE IN STANDBY OR CHARGING MODE

  1. Set  up  the  battery  charger  and  connect  to  the  battery  following  steps  1  through  2  in  the 

“Charging the Battery” section.

  2. Press the battery voltage check button. The LCD screen will display the following:

  The digital display shows the current voltage of the connected battery for 10 seconds. During 

this period, pressing the battery voltage check button again will return the unit to standby mode 

or charging mode. Pressing any other buttons will have no effect. The unit will automatically 

return to standby or charging mode after 10 seconds.

 

Notes:

 If the clamps are correctly connected with regard to polarity and the unit is properly 

connected to the AC outlet, the unit will be in Standby mode and the LCD screen will display the 

following (the clamp icons, arrow icons and the battery icon light solid) and the battery charge 

gauge will indicate the battery’s current charge status) 

 

If the clamps are INCORRECTLY connected with regard to polarity, the LCD screen will display 

the following (the “+” and “–” inside the battery icon, the clamp icons and the fault icon will flash 

and the battery icon will light) and a warning will sound until the clamps are disconnected:

  Unplug the charger; then remove the clamps. Reconnect the clamps properly.
  3. When the unit is properly connected, press the battery charge button on the control panel. The 

LCD screen will display the following:

  The digital display shows the output current that is charging the battery. The gauge indicates 

the charge status of the battery. The clamp icons and the battery icon light solid, and the arrow 

icons will gradually and repeatedly move downward to the battery icon.

  Notes: 

The “ ” icon will appear at the top right of the gauge section if the surrounding ambient 

temperature is higher than approximate 40°C. The “ ” icon will appear at the top left of the 

gauge section if the surrounding ambient temperature is lower than 0°C. This is not a fault code, 

but indicates that the unit’s temperature compensation feature is operating. 

  The charging process will start automatically approximately one minute after the unit is properly 

connected.

 

IMPORTANT:

 If the battery is overheated, the LCD screen will display the following flashing 

icons:

  Disconnect the charger. Have the battery checked by a qualified technician.

BC15_30_40BWM_ManualEN_120513.indd   10-11

12/5/2013   3:53:06 PM

Содержание 14982045

Страница 1: ...DEL 14982045 15Amp with Engine Start Timer DOCKSIDE BATTERY CHARGER MODELS 14982052 14982060 30Amp and 40Amp with Engine Start Owner s Manual 14982045 14982052 14982060 BC15_30_40BWM_ManualEN_120513 i...

Страница 2: ...8 14 16 16 12 10 8 16 18 14 12 8 8 18 20 14 12 8 6 SAFETY GUIDELINES DEFINITIONS HAZARD Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING...

Страница 3: ...acid to come in contact with this unit Do not operate this unit in a closed area or restrict ventilation in any way Always turn the battery charger off by unplugging it when not in use Power Cord Safe...

Страница 4: ...t SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF INJURY Follow these instructions and those published by the battery manufacturer and manufacturer of any equipment you intend to use with this u...

Страница 5: ...al 1 Plug the battery charger s power cord into an AC outlet The LCD screen will display the following the clamp icon will flash and the empty battery icon will light 2 The charger s battery clamps ar...

Страница 6: ...the battery voltage check button again will return the unit to standby mode or charging mode Pressing any other buttons will have no effect The unit will automatically return to standby or charging mo...

Страница 7: ...THE ALTERNATOR IS RATED TO SUPPORT THE APPLICATION This check may not be accurate for every make manufacturer and model of vehicle Check only 12 volt systems When disconnecting the charger disconnect...

Страница 8: ...te and turn these chemicals into useful battery electrolytes The process will stop automatically after 24 hours To stop the process sooner press the battery recondition button a second time More than...

Страница 9: ...ure that unit is completely disconnected from battery and power source before cleaning To maintain the operating condition and maximize the life of the charger cords always coil them loosely for stora...

Страница 10: ...ed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If th...

Страница 11: ...Toll Free 1 877 571 2391 www westmarine com 2013 West Marine All rights reserved WM_Version 1_DEC 2013 BC15_30_40BWM_ManualEN_120513 indd 20 12 5 2013 3 53 07 PM...