User manual
User-manual-TopLine-v.02 Deutsch 4-43
– English 44-79 – Français 80-114
01/2021
51
4.3 Technical data and operating conditions W21 L,LE,W
Model
W21 L
W21 LE
W21 W
General data
Machine dimensions
-without feet-
H x W x D (mm)
475 x 365 x 530
540 x 460 x 530
475 x 365 x 530
Adjustable feet
from - till (mm)
10-25
Weight (kg)
33
38
33
Cooling
Air
Air
Water
Refrigerant
R 290 (GWP-Wert: 3)
Cooling capacity
344 W
Production data
Production (kg per day)
about. 24
Storage (kg)
about. 9
Water consumption of ice making
(litres per kg ice)
about. 3,3
Water consumption of cooling
system (litres per kg ice)
-
-
about. 6,6
Power supply
Voltage
230 V ~ / 50 Hz
Power consumption
0,30 kW
0,35 kW
0,30 kW
Fuse (provided by customer)
10 A
Length of connection cable
about. 2,0 m
Water supply
Pressure
2 bis 6 bar
Temperature
5
–25 °C
Water hardness
max. 25 °dH *)
max. 15 °dH *)
Water inlet
device connection -Ø
¾“ - male thread
hose
–Ø / -length
DN 8 (incl. 2x ¾“ - female thread) / about. 1,5 m
Water outlet
device connection -Ø
20 mm
hose
–Ø / -length
DN 20 / about. 1,4 m
Cooling water outlet
device connection -Ø
-
-
10 mm
hose
–Ø / -length
-
-
DN 10 / about. 1,4 m
Environmental conditions
Temperature
10-40°C
Installation position
firm surface, good ventilation
Installation height
at least 10 cm above outlet pipe
The installation surface must be suitable for the weight of the machine.