spa unit.

4. Remove the drainage hose from the spa and

attach a garden hose to the valve on the drainage
hose.

5. Open the valve by turning the knob counterclock-

wise. The water will begin to drain.

6. When the spa is empty, close the valve and

remove the garden hose. Return the drainage
hose to the clip and replace the access cover.

7. Refill the spa and treat the water with chemicals

(see pages 10 and 14).

DRAINING THE PUMP

After the hydrotherapy
spa is drained (see
DRAINING THE
HYDROTHERAPY SPA
on page 14), the pump
should also be drained
if the hydro-therapy
spa will be stored for
more than thirty days,
or if it may be exposed
to freezing temperatures.

To drain the pump, remove the access cover from the
spa unit (see ATTACHING AND REMOVING THE

ACCESS COVER on page 14). Locate the pump
inside the spa unit. Remove the drain plug from the
pump and allow all water to drain from the pump.
Replace the drain plug.

WINTER USE AND CARE

The hydrotherapy spa is designed for year-round use.
If you decide to store the hydrotherapy spa for the win-
ter, store it in a warm, dry location. Follow the steps
below to winterize the hydrotherapy spa.

1. Drain the spa (see DRAINING THE

HYDROTHERAPY SPA on the previous page and
this page).

2. Remove all remaining water from the spa shell.

Dry the spa shell with towels.

3. Set the air control on the console to the lowest

setting. Use a wet/dry vacuum to pull any remain-
ing water from the system. To do this, place the
vacuum nozzle over each jet, starting with the
highest jet and finishing with the lowest one. 

4. Set the air control on the console to the highest

setting and repeat step 3.

5. Drain the pump (see DRAINING THE PUMP on

this page). Once the water has drained from the
pump, place the vacuum nozzle over the drainage
hole in the pump and vacuum any additional water
from the pump. 

Note: For additional protection

you can remove the pump/motor from the spa
to store it in a climate-controlled room.

6. Clean the spa shell (see page 13).
7. Clean the filter (see page 13).
8. A qualified electrician should disconnect the power

cord from the 240 volt power source, if so wired.

9. Re-attach the access cover and re-attach the spa

cover.

Drain Plug

Pump

Pump

Motor

Drain

Hose

Valve

Knob

Cap

Содержание Daybreak 408

Страница 1: ...IRECT TO OUR TOLL FREE CUSTOMER HOT LINE The trained techni cians on our customer hot line will provide immediate assis tance free of charge to you CUSTOMER HOT LINE 1 800 999 3756 Mon Fri 6 a m 6 p m...

Страница 2: ...where all users of the hydrotherapy spa will be able to see it Whenever the spa is moved the sign must also be moved and reposted near the spa If the sign becomes illegible or if it is lost call our t...

Страница 3: ...These high temperatures can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not...

Страница 4: ...and lock the spa cover when the hydrotherapy spa is not in use 29 WARNING To reduce the risk of injury The water temperature should never exceed 104 F Temperatures between 100 F and 104 F are consider...

Страница 5: ...st be posted where all users of the spa can see and read it See POSTING THE WARNING SIGN on page 2 40 Before entering a spa the user should mea sure the water temperature with an accurate thermometer...

Страница 6: ...py spa gives you the specialized treatment you need to feel your best For your benefit read this manual carefully before using the DAYBREAK 408 If you have additional questions please call our Custom...

Страница 7: ...f the spa provided you leave access to the motor for ser vice 9 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the hyd...

Страница 8: ...e 1 phillips screwdriver You may also need some soap or water A wire connector is provided on the pump motor of this unit to connect a minimum No 8 AWG 804 mm2 solid copper conductor between this unit...

Страница 9: ...e Inflatable Cover is lined up with the warning label on the Spa Cover Attach the other three straps on the inside of the Spa Cover 11 through the loops on the Inflatable Cover 4 in the same manner Pl...

Страница 10: ...mine Base are correct Always keep the chemi cals away from children and pets The first time you use the spa you should test and treat the water You must also treat the water each time you refill the s...

Страница 11: ...re Use of the console D is explained on page 12 of this manual The hydrotherapy spa offers an automatic freeze pro tection If the water temperature falls below 40 F the pump will begin circulating the...

Страница 12: ...ll run at high speed pro viding more intense hydrotherapy Press the button a third time and the spa will shut off The spa also features an automatic mode which heats and filters the water when the spa...

Страница 13: ...L The spa shell should be cleaned with a mild soap solution Do not use solvents The spa should always be clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cl...

Страница 14: ...urchase additional test strips or purchase a pH test kit at a pool and spa supply store The pH read ing should be between 7 2 and 7 8 If the level is too low add a pH increaser usually soda ash If the...

Страница 15: ...the hydrotherapy spa for the win ter store it in a warm dry location Follow the steps below to winterize the hydrotherapy spa 1 Drain the spa see DRAINING THE HYDROTHERAPY SPA on the previous page an...

Страница 16: ...nce is an important part of keeping your spa in top operating condition Use the space below to make any special notes you may want to remember for future reference or to keep a maintenance log Mainten...

Страница 17: ...per ature b If you are using the hydrotherapy spa outdoors it may take longer for the water to heat See the chart below for the approximate heating time Air Temperature Heating Time 70 F 24 to 36 hour...

Страница 18: ...ey 22 39 1 On Off Switch Assembly 40 1 Air Diverter Knob 41 1 On Off Wire Harness 42 1 See Key 41 43 2 Wire Tie 44 1 Probe Guard Assembly 45 1 Overlay 46 2 Rubber O ring 47 1 Rubber Grommet 48 8 5 16...

Страница 19: ...23 50 6 5 24 24 21 14 5 6 12 35 36 36 29 4 46 28 27 47 20 35 36 32 33 33 48 40 39 37 45 15 8 16 7 2 7 9 10 26 13 18 19 18 17 31 30 44 42 38 49 41 22 43 25 7 3 1 34 Exploded Drawing Model No WLHS43080...

Страница 20: ...mages caused by or attributable to the following incidents any damage to the wood exterior resulting from improper maintenance or any damage to the wood or tile exteri or attributable to freight misha...

Отзывы: