Inspect and tighten all parts of the exercise cycle reg-

ularly. Replace any worn parts immediately.

To clean the exercise cycle, use a damp cloth and a

small amount of mild detergent.

Important: To avoid

damage to the console, keep liquids away from

the console and keep the console out of direct

sunlight.

BATTERY REPLACEMENT

If the console display becomes dim, the batteries

should be replaced; most console problems are the

result of low batteries. To replace the batteries, see

step 5 on page 5 and remove the console from the

handlebar. Next, see step 4 on page 5 and insert

three batteries into the console. Reattach the console

to the handlebar, being careful not to pinch the wires.

HOW TO ADJUST THE REED SWITCH

If the console does not display correct feedback, the

reed switch should be adjusted. In order to adjust the

reed switch, the left side shield must be removed.
Turn the Crank (21) to the position shown. Using an

adjustable spanner, turn the Left Pedal (24) clockwise

and remove it. Next, remove the five M4 x 25mm

Screws (52) and the M4 x 19mm Screw (54) from the

Left Side Shield (17). Carefully remove the Left Side

Shield.

Next, locate the Reed Switch (43). Turn the Crank

(21) until the Magnet (38) is aligned with the Reed

Switch. Loosen, but do not remove, the M4 x 12mm

Screw (46). Slide the Reed Switch slightly closer to or

away from the Magnet, and then retighten the Screw.

Turn the Crank for a moment. Repeat until the con-

sole displays correct feedback. When the Reed

Switch is correctly adjusted, reattach the left side

shield and the left pedal.

MAINTENANCE AND TROUBLESHOOTING

52

54

17

21

38

43

52

24

21 46

Содержание Boomerang 403

Страница 1: ...nual for future reference Serial Number Decal Model No WLEVEX29840 Serial No QUESTIONS As a manufacturer we are com mitted to providing complete customer satisfaction If you have questions or if there...

Страница 2: ...our back 9 If you feel pain or dizziness whilst exercising stop immediately and cool down 10 The pulse sensor is not a medical device Various factors including the user s move ment may affect the accu...

Страница 3: ...ave questions after reading this manual please call our Customer Service Department at 0034 91 661 02 10 To help us assist you please note the product model number and serial number before calling The...

Страница 4: ...the key number is the quantity used in assembly Note Some small parts may have been preassembled for ship ping If a part is not in the parts bag check to see if it has been pre assembled M8 Nylon Lock...

Страница 5: ...push it toward the upright and then turn it clockwise again 4 4 The Console 16 requires three AA batteries alka line batteries are recommended Insert three batteries into the Console Make sure that th...

Страница 6: ...45 and insert the tip of the console cable B into the wire clip inside of the metal bracket See inset drawing B Firmly pull the console cable B and slide it into the metal bracket A on the Lower Cable...

Страница 7: ...exercise cycle for one week retighten the Pedals For best performance the Pedals must be kept tightened Adjust the left Pedal Strap 25 to the desired position and press the end of the Pedal Strap onto...

Страница 8: ...e upright up or down and align one of the adjustment holes in the upright with the indicated hole in the frame Insert the knob into the frame and the upright and turn the knob clockwise until it is ti...

Страница 9: ...e To turn on the console press the On Reset button or begin pedalling Note If there is a sheet of clear plastic on the console remove it Select the manual mode Each time the console is turned on the m...

Страница 10: ...hen you are finished exercising the console will automatically turn off after a few minutes If the pedals are not moved and the console but tons are not pressed for a few minutes the con sole will aut...

Страница 11: ...adjust the resistance of the exercise cycle as desired by turning the resist ance knob The display will show the time remaining in the program If you continue exercising after the pro gram is complete...

Страница 12: ...REED SWITCH If the console does not display correct feedback the reed switch should be adjusted In order to adjust the reed switch the left side shield must be removed Turn the Crank 21 to the positi...

Страница 13: ...xercise Aerobic Exercise If your goal is to strengthen your cardiovascular sys tem your exercise must be aerobic Aerobic exer cise is activity that requires large amounts of oxygen for prolonged perio...

Страница 14: ...3 8 Axle Nut 33 2 Right Stabiliser Endcap 34 2 M6 Nylon Locknut 35 1 M10 Flat Washer 36 1 Seat Knob 37 1 Flywheel 38 1 Magnet 39 1 Flywheel Axle 40 2 Flywheel Bearing 41 1 C Magnet 42 1 Handlebar Clam...

Страница 15: ...2 25 24 26 25 9 31 31 34 34 10 10 37 38 39 40 40 41 43 44 6 45 47 53 48 19 23 23 10 10 30 30 42 49 54 46 51 10 28 28 28 28 35 29 29 27 17 52 52 54 10 51 51 10 51 49 54 54 52 36 56 56 50 32 54 54 4 20...

Страница 16: ...m When ordering parts please be prepared to give the following information the MODEL NUMBER of the product WLEVEX29840 the NAME of the product BOOMERANG 403 exercise cycle the SERIAL NUMBER of the pro...

Отзывы: