Inspection:

Official periodic inspection must be made at least annually. The inspection must be performed by a qualified 

person other than the intended user. If severe environmental conditions exist then inspections must be 

carried out more frequently. All inspection results must be logged in the space provided above.

 

 

1.

  Inspect Swivel to make sure it is flush with mounting surface.

 

2.

  Ensure all labeling is affixed to the unit.

 

3.

  Ensure the unit can rotate 360° and D-ring can flip from side to side.

 4.

  When reusing a previously drilled hole, inspect for debris or wallowing.

 

5. 

 Record inspection results in the space provided above.

MAINTENANCE, CLEANING AND STORAGE

Cleaning periodically will prolong the life and proper functioning of the product. The frequency 

of cleaning should be determined by inspection and by severity of the environment. Clean with 

compressed air and/or a stiff brush using plain water or a mild soap and water solution. Do not use 

any corrosive chemicals that could damage the product. Wipe all surfaces with a clean, dry cloth 

and hang to dry, or use compressed air. When not in use, store anchorage connectors in a cool, dry, 

clean environment, out of direct sunlight and free of corrosive or other degrading elements.

 

 

 

*If inspection reveals any damage that could affect the strength or operation of the 

device, inadequate maintenence, or an unsafe condition, proper disposal is required. 

The anchorage connector must be rendered unusable and then properly discarded.

MODEL NUMBER:

DATE OF MANUFACTURE:

INSPECTION AND MAINTENANCE LOG

Date

Part Number

Comments

Inspector Name

Page 7

Содержание A320013

Страница 1: ...O MAY RESULT IN SERIOUS INJURY OR DEATH USERS SHOULD BE FAMILIAR WITH PERTINENT REGULATIONS GOVERNING THIS EQUIPMENT ALL USERS OF THIS PRODUCT MUST BE PROPERLY INSTRUCTED ON HOW TO USE THE DEVICE AVOID CONTACT WITH PHYSICAL HAZARDS THERMAL CHEMICAL ELECTRICAL ETC MAKE ONLY COMPATIBLE CONNECTIONS V3 0 D Page 1 OPERATION AND INSTRUCTION MANUAL Swivel Anchor Models A320013 A320014 A510011 Additional ...

Страница 2: ...onnector has been tested in compliance with the requirements of ANSI ASSE Z359 7 Compliance testing covers only the hardware and does not extend to the anchorage and substrate to which the anchorage connector is attached The anchorage connector must not be used outside its limitations or for any purpose other than that for which it is intended If this anchorage connector is used differently from t...

Страница 3: ...s 544 3g Materials Zinc Plated Steel Regulatory Compliance Meets or exceeds ANSI Z359 18 Type A ANSI Z359 7 2019 OSHA 29 CFR 1926 502 OSHA 29 CFR 1910 140 Page 3 180 360 IMPROPER U S P A T E N T 8 4 2 4 6 3 8 U T S 5 0 0 0 LBF PLATED AL L O Y S T E E L M S X X X M M Y Y 8 inches ø 203 2mm 5 5 inches 139 7mm 3 inches 76 2mm 2 25 inches ø 57 15mm ...

Страница 4: ... debris Concrete strength must be at least 3000psi 20 7MPa and no less than 7 inches 178mm thick 7 inch 178mm min drill 5 inch 13mm Ø 8 inch 203mm min from any edge STEEL MOUNTING Use tapered washer drill 5 inch 13mm Ø 25 inch 6mm min 3 inches 76mm min from any edge 5 inch 13 inch Lock Nut 5 inch Lock Washer 5 inch 13 x 4 inches Hex Bolt Torque 45 ft lbs 61 Nm Embedment Depth 4 min 101mm 3 75 inch...

Страница 5: ...t 5 000 lbf 22kN and installed under the supervision of a qualified person MINIMUM CLEARANCE 2 feet 6m DECK FLOOR GROUND LEVEL WARNING SWING FALLS MAY OCCUR WHEN THE WORKER IS NOT DIRECTLY UNDER ANCHOR POINT The user shall be equipped with a means of limiting the maximum dynamic forces exerted on the user during the arrest of a fall to a maximum of 1800 lbf 8 kN WORK SURFACE Page 5 ...

Страница 6: ...AL KIT CONTENTS PART NUMBER A320011 Steel Mounting Hardware Kit A320014 Swivel with Steel Mounting kit A510012 Concrete Hardware Kit A510011 Swivel with Concrete Mounting Kit For more information A320013 Anchor Swivel 5K ...

Страница 7: ...ng the life and proper functioning of the product The frequency of cleaning should be determined by inspection and by severity of the environment Clean with compressed air and or a stiff brush using plain water or a mild soap and water solution Do not use any corrosive chemicals that could damage the product Wipe all surfaces with a clean dry cloth and hang to dry or use compressed air When not in...

Страница 8: ...Werner Co 93 Werner Road Greenville PA 16125 1 724 588 2000 1 888 523 3371 toll free 1 888 456 8458 fax P N 109313 01 REV B 4 21 Page 8 ...

Отзывы: