GRANUDOS 45/100 PLUS V70 Touch
Index: 03
Change date: 25.04.2018
Operating instructions no.: BA SW 001-03 Granudos 45-100 PL V70T.docx
Page 72 of 92
ATTENTION !
The hose may not be twisted after insertion.
Take note of the markers!
Fasten the hose ends with the hose binders and cut off protruding parts of the hose
binders. Turn the roller carriers anticlockwise and carefully press the hose into the
housing (also see Figures in
Section 5.2.1, Install the hose
) Click
back the lock washer and the pump cover.
7.1.8
Cleaning of the dust extraction (option)
a.
Disconnect the device and secure against
new connection.
b.
Loosen the two lateral screws.
c.
Lift the motor upwards out of the
blower.
d.
Clean blower and tank
e.
Disassemble the transparent hose and
clean with the supplied brush.
f.
Assemble in reverse order.
7.2
Regular water inspection
Regular water inspection is essential for problem- and fault free operation of the
system. The pH value of the buffer tank must be checked every 2 months.
Figure60, Dust extraction