8.12. Connections
One exclusive owner connection and several input/lists only connections are supported. The exclusive owner
connection transmits exactly one byte in both directions. Up to four of the lower bits of this byte are valid for
each direction. The maximum total number of valid bits for both directions corresponds to the number of physi-
cal inputs and outputs of the device, i.e. four.
Producing assembly (input) is on instance 7 decimal.
Consuming assembly (output) is on instance 37 decimal.
Structure of the assembly:
There is exactly 1 byte with the following assignment
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
—
—
—
—
Port 1
Pin 4
Port 0
Pin 4
Port 1
Pin 2
Port 0
Pin 2
9. Web-based Configuration
The switch is equipped with a web-based setting interface, which works independently of the operating system.
You can easily set parameters for the switch using a standard web browser. In delivery condition the device
expects the IP address from a DHCP server. It is not needed for normal operation on the controller.
Attention:
When using on a controller, settings changed through the website are overwritten by the controller.
9.1. Call up the Administration Interface
Start the web browser. Enter the IP address of the switch into the address line of your browser and press the
ENTER key. Enter the manually configured IP address of the switch in the address bar of your browser and
press the enter button. To ensure that the browser displays the current website settings, the website in ques-
tion must always be refreshed automatically in case of change. This setting must be changed browser-specific
and is demonstrated here by means of Internet Explorer as an example. Under
Extras
Internet Options
Browsing history
Settings
the selection should be set to
Every time I visit the webpage.
Otherwise, any
changes to the homepage might be displayed incorrectly.