7.8. Operation using a controller without EDS file use
If you wish to start up the device on a controller, please carry out the following steps:
• Attach the switch to the supply voltage and connect this to the controller via one of the Ethernet ports.
You can find the appropriate connection technology on the wenglor homepage.
• Create a new project in the controller
• Add a new module to this project
• When selecting the communication module „General Ethernet module“ should be used
• The properties of the new module should match the connection parameters of the relevant product. In the
example of the switch the communication format selected should be „Data SINT“. To be able to access the
switch in the network an IP address should be assigned in addition. In delivery condition this is requested
by the product via a DHCP server.
• Creating the Config Assembly (not mandatory). Default Config = I/O ports to input, active performance
monitoring, all ports are released for PoE
• After the program has been created, connect to the controller and load program
For a detailed description for different controllers and for installation of the files or project planning of the net-
work refer to the help files of the relevant controller. wenglor provides a short exemplary instruction for commis-
sioning of an EtherNet/IP
TM
device
(www.wenglor.com
Product World
Product search (order number)
Download
General instructions)
.