61
Type 4 Safety Light Curtain
Testing the effectiveness of the ESPE:
• Testing may only be conducted when hazardous motion has been switched off.
• Testing must be conducted with a test rod, and not by reaching in with the hand.
• Test rod diameter: in accordance with ESPE resolution
Testing the “automatic start-up function” (safety mode):
• The OSSD ON display must light up before testing is started.
• Pass the test rod through the entire safety field as shown in the figure.
• The OSSD OFF display must be lit up as long as the test rod is in the safety field.
Testing the “restart inhibit” function:
• The RES display must blink before testing is started.
• Pass the test rod through the safety field as shown in the figure.
• The OSSD OFF display must remain lit up as long as the test rod is in the safety field.
• The RES display may not light up as long as the test rod is in the safety field.
Empfänger
Sender