Safety Light Curtain
109
7.1 Positioning the ESPE
The following points must be observed when aligning the ESPE:
Same mounting height
• The emitter and receiver must be mounted parallel to
each other and at the same mounting height.
Parallel alignment
• The emitter and receiver must be mounted so that a
rectangular safety field is formed.
Same alignment in relation to each other
• The plug connectors of the emitter and receiver
must point in the same direction.
• They must not be installed turned 180° away from each
other.