background image

4

General

1.3 Limitation of Liability

• The product has been developed in consideration of the current state-of-the-art and applicable standards 

and guidelines. Subject to change without notice.

• A valid declaration of conformity can be accessed at www.wenglor.com in the product’s separate 

 download  area.

• wenglor sensoric elektronische Geräte GmbH (hereinafter referred to as “wenglor”) excludes all liability in 

the event of:

• Non-compliance with the instructions
• Use of the product for purposes other than those intended
• Use by untrained personnel
• Use of unapproved replacement parts
• Unapproved modification of products

• These operating instructions do not include any guarantees from wenglor with regard to the described 

procedures or specific product characteristics.

• wenglor assumes no liability for printing errors or other inaccuracies contained in these operating 

 instructions, unless wenglor was verifiably aware of such errors at the point in time at which the operating 
 instructions were prepared.

1.4 Copyrights

• The contents of these instructions are protected by copyright law.
• All rights are reserved by wenglor.
• Commercial reproduction or any other commercial use of the provided content and information, in 

 particular graphics and images, is not permitted without previous written consent from wenglor.

Содержание P2KK Series

Страница 1: ...ns EN Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 0 1 Status 09 05 2022 www wenglor com P2KKxxx Retro Reflex Sensors for...

Страница 2: ...class 6 3 Technical Data 7 3 1 Technical Data 7 3 1 1 Spot diameter 8 3 1 2 Smallest detectable part 8 3 1 3 Switching distance 8 3 2 Complementary Products 9 3 3 Layout 9 3 4 Control Panel 10 3 5 Sc...

Страница 3: ...d by means of symbols and attention getting words Safe use of the product is only possible if these safety precautions and warnings are adhered to The safety precautions and warnings are laid out in a...

Страница 4: ...pproved replacement parts Unapproved modification of products These operating instructions do not include any guarantees from wenglor with regard to the described procedures or specific product charac...

Страница 5: ...can be used in the following industry sectors Special machinery manufacturing Heavy machinery manufacturing Logistics Automotive industry Food industry Packaging industry Pharmaceuticals industry Pla...

Страница 6: ...roduct is modified Personal injury and damage to equipment may occur Non observance may result in loss of the CE marking and the guarantee may be rendered null and void Modification of the product is...

Страница 7: ...ge 24 V 20 mA Switching frequency 2000 Hz Switching frequency speed mode 3500 Hz Response time 0 25 ms Response time speed mode 0 14 ms Temperature drift 5 Temperature range 40 60 C Switching output v...

Страница 8: ...rs are listed in the following tables Reflector Range RQ100BA 0 1 50 m RE18040BA 0 1 50 m RQ84BA 0 1 50 m RR84BA 0 1 50 m RE9538BA 0 0 70 m RE6151BM 0 1 30 m RR50_A 0 1 50 m RE6040BA 0 1 40 m RE8222BA...

Страница 9: ...Suitable mounting technology no Suitable connection technology no 7 IO Link master EFBL001 EFBL003 EP0L001 wTeach2 software DNNF005 Software IO Link Device Tool DNNF019 Hygienically designed screws B...

Страница 10: ...f damage con ditionally accept the package and notify the manufacturer of the damage Then return the device making reference to damage in transit 4 2 Storage The following points must be taken into co...

Страница 11: ...put Ground for the Trigger Input Analog Output Ground for the Analog Output Block Discharge Valve Output Valve Control Output Valve Control Output 0 V Synchronization Ground for the Synchronization Re...

Страница 12: ...arning blinking LED Display LED Diagnosis Cause Elimination Continuous blinking at approx 2 5 Hz Contamination Carefully clean the optic cover with a cloth Aged emitter diode Replace the sensor Unreli...

Страница 13: ...Reflector Sensor Reflector Object Sensor Reflector Object Object Sensor Reflector Sensor Reflector Object Sensor Reflector Object Required action in case of fault NOTE Shut down the machine Analyze a...

Страница 14: ...settings are possible via the IO Link interface The IODD can be found at www wenglor com in the product s download area 8 Maintenance Instructions NOTE This wenglor sensor is maintenance free Cleaning...

Страница 15: ...re 10 2 Change Index Operating Instructions Version Date Description Change 1 0 0 04 08 21 Initial version of the operating instructions 1 0 1 09 05 22 Actualization see section 3 Technical Data on pa...