Wenglor P1PK Series Скачать руководство пользователя страница 12

12

Installation and Electrical Connection

DANGER!
Risk of personal injury or property damage due to electric current!
Voltage conducting parts may cause personal injury or damage to equipment.

 

• The electric device may only be connected by appropriately qualified personnel.

5.3 Diagnostics

Causes for Triggering the Contamination Warning (blinking LED):

Display LED

Diagnosis/Cause

Elimination

Continuous blinking 
at approx. 2.5 Hz

Contamination

Carefully clean the optic cover with a cloth.

Aged emitter diode

Replace the sensor.

Unreliable working range

• Increase the sensor’s switching distance.
• Reduce distance between sensor and reflector.

Continuous blinking 
at approx. 5 Hz

Short-circuit

Check electrical wiring and eliminate the short-circuit.

Over-temperature

Disconnect the sensor from supply power  
and allow it to cool down.

Hardware error

Replace the sensor.

Содержание P1PK Series

Страница 1: ...EN Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 0 0 Status 06 12 2018 www wenglor com P1PKxxx Retro Reflex Sensors for Cl...

Страница 2: ...al Safety Precautions 6 2 6 Approvals and protection class 6 3 Technical Data 7 3 1 Complementary Products 9 3 2 Layout 9 3 3 Control Panel 10 3 4 Scope of Delivery 10 4 Transport and Storage 10 4 1 T...

Страница 3: ...zed by means of symbols and attention getting words Safe use of the product is only possible if these safety precautions and warnings are adhered to The safety precautions and warnings are laid out in...

Страница 4: ...pproved replacement parts Unapproved modification of products These operating instructions do not include any guarantees from wenglor with regard to the described procedures or specific product charac...

Страница 5: ...ct can be used in the following industry sectors Special machinery manufacturing Heavy machinery manufacturing Logistics Automotive industry Food industry Packaging industry Pharmaceuticals industry P...

Страница 6: ...uct is modified Personal injury and damage to equipment may occur Non observance may result in loss of the CE marking and the guarantee may be rendered null and void Modification of the product is imp...

Страница 7: ...rating voltage 24 V 20 mA Switching frequency 2000 Hz Switching frequency speed mode 3500 Hz Response time 0 25 ms Response time speed mode 0 14 ms Temperature drift 5 Temperature range 40 60 C Switch...

Страница 8: ...able ranges for other reflectors are listed in the following tables Reflector Range RQ100BA 0 2 60 m RE18040BA 0 1 50 m RQ84BA 0 1 80 m RR84BA 0 2 20 m RE9538BA 0 0 85 m RE6151BH 0 0 90 m RE6151BM 0 2...

Страница 9: ...use reflectors with microstructure 3 1 Complementary Products wenglor can provide you with suitable connection technology for your product Suitable mounting technology no 380 Suitable connection tech...

Страница 10: ...nsit In the case of damage con ditionally accept the package and notify the manufacturer of the damage Then return the device making reference to damage in transit 4 2 Storage The following points mus...

Страница 11: ...nput Test Input inverted Trigger Input Analog Output Ground for the Analog Output Block Discharge Valve Output Valve Control Output Valve Control Output 0 V Synchronization Receiver Line Emitter Line...

Страница 12: ...arning blinking LED Display LED Diagnosis Cause Elimination Continuous blinking at approx 2 5 Hz Contamination Carefully clean the optic cover with a cloth Aged emitter diode Replace the sensor Unreli...

Страница 13: ...or Reflector Sensor Reflector Object Sensor Reflector Object Object Sensor Reflector Sensor Reflector Object Sensor Reflector Object Required action in case of fault NOTE Shut down the machine Analyze...

Страница 14: ...settings are possible via the IO Link interface The IODD can be found at www wenglor com in the product s download area 8 Maintenance Instructions NOTE This wenglor sensor is maintenance free Cleaning...

Страница 15: ...tage IODD IO Device Description MTTFd Mean Time to Dangerous Failure 10 2 Change Index Operating Instructions Version Date Description Change 1 0 0 06 12 18 Initial version of the operating instructio...

Отзывы: