background image

13

Retro-Reflex Sensors for Clear Glass Recognition

Contamination Warning Flowcharts

not detected

not detected

detected

beginning contamination

not detected

not detected

 detected

Retro Reflective Barrier

no contamination

Object

Switching Status Indicator

Object

Switching Status Indicator

Object

Switching Status Indicator

not detected

not detected

not detected

advanced contamination

on

on

off

off

off

off

off

blinking

blinking

Object

t

Sensor

Reflector

Sensor

Reflector

Object

Sensor

Reflector

Object

Object

Sensor

Reflector

Sensor

Reflector

Object

Sensor

Reflector

Object

Object

Sensor

Reflector

Sensor

Reflector

Object

Sensor

Reflector

Object

Required action in case of fault:

NOTE!

• Shut down the machine.
• Analyze and eliminate the cause of error with the help of the diagnostics information.
• If the error cannot be eliminated, please contact wenglor’s support department.
• Do not operate in case of indeterminate malfunctioning.
• The machine must be shut down if the error cannot be unequivocally clarified or reliably 

eliminated.

DANGER!
Risk of personal injury or property damage in case of non-compliance!

The system’s safety function is disabled. Personal injury and damage to equipment.

 

• Required action as specified in case of fault.

Содержание P1NK Series

Страница 1: ...EN Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 0 0 Status 25 07 2018 www wenglor com P1NKxxx Retro Reflex Sensors for Cl...

Страница 2: ...class 6 3 Technical Data 7 3 1 Technical Data 7 3 1 1 Spot diameter 8 3 1 2 Smallest detectable part 8 3 1 3 Switching distance 8 3 2 Complementary Products 9 3 3 Layout 9 3 4 Control Panel 10 3 5 Sc...

Страница 3: ...zed by means of symbols and attention getting words Safe use of the product is only possible if these safety precautions and warnings are adhered to The safety precautions and warnings are laid out in...

Страница 4: ...pproved replacement parts Unapproved modification of products These operating instructions do not include any guarantees from wenglor with regard to the described procedures or specific product charac...

Страница 5: ...ct can be used in the following industry sectors Special machinery manufacturing Heavy machinery manufacturing Logistics Automotive industry Food industry Packaging industry Pharmaceuticals industry P...

Страница 6: ...uct is modified Personal injury and damage to equipment may occur Non observance may result in loss of the CE marking and the guarantee may be rendered null and void Modification of the product is imp...

Страница 7: ...ption operating voltage 24 V 20 mA Switching frequency 2000 Hz Switching frequency speed mode 3500 Hz Response time 0 25 ms Response time speed mode 0 14 ms Temperature drift 5 Temperature range 40 60...

Страница 8: ...nge Reflector Range RQ100BA 0 2 60 m RR21_M 0 0 65 m RE18040BA 0 1 50 m ZRME01B01 0 0 25 m RQ84BA 0 1 80 m ZRME03B01 0 1 10 m RR84BA 0 2 20 m ZRAE02B01 0 0 90 m RE9538BA 0 0 85 m ZRMR02K01 0 0 30 m RE...

Страница 9: ...an provide you with suitable connection technology for your product Suitable mounting technology no 350 Suitable connection technology no 2 S02 IO Link master wTeach2 software DNNF005 3 3 Layout 1 Opt...

Страница 10: ...case of damage con ditionally accept the package and notify the manufacturer of the damage Then return the device making reference to damage in transit 4 2 Storage The following points must be taken i...

Страница 11: ...Input Ground for the Trigger Input Analog Output Ground for the Analog Output Block Discharge Valve Output Valve Control Output Valve Control Output 0 V Synchronization Ground for the Synchronization...

Страница 12: ...arning blinking LED Display LED Diagnosis Cause Elimination Continuous blinking at approx 2 5 Hz Contamination Carefully clean the optic cover with a cloth Aged emitter diode Replace the sensor Unreli...

Страница 13: ...or Reflector Sensor Reflector Object Sensor Reflector Object Object Sensor Reflector Sensor Reflector Object Sensor Reflector Object Required action in case of fault NOTE Shut down the machine Analyze...

Страница 14: ...settings are possible via the IO Link interface The IODD can be found at www wenglor com in the product s download area 8 Maintenance Instructions NOTE This wenglor sensor is maintenance free Cleaning...

Страница 15: ...tage IODD IO Device Description MTTFd Mean Time to Dangerous Failure 10 2 Change Index Operating Instructions Version Date Description Change 1 0 0 25 07 18 Initial version of the operating instructio...

Отзывы: