8
Technical Data
3.1 Spot Diameter
Range
60 mm
250 mm
500 mm
Spot diameter
11 mm
13 mm
15 mm
Table 1
Range
160 mm
400 mm
800 mm
Spot diameter
16 mm
20 mm
23 mm
Table 2
Range
65 mm
150 mm
300 mm
Spot diameter
3 mm
2,5 mm
1,5 mm
Table 3
3.2 Switching Frequency / Response Time
The switching frequency and the response time are depending on 2 settings: operating mode and switching
outputs. The following values result according to the setting:
Operating Mode
Outputs
2 independent switching outputs
1 switching output
Switching Frequency (Standard Mode)
150 Hz*
800 Hz
Response Time (Standard Mode)
3,3 ms*
1,25 ms
Switching Frequency (Interference-free Mode)
100 Hz
500 Hz
Response Time (Interference-free Mode)
5 ms
1,9 ms
*preset configuration
Table 4
Operating Mode
Outputs
2 independent switching outputs
1 switching output
Switching Frequency (Standard Mode)
100 Hz*
500 Hz
Response Time (Standard Mode)
4,2 ms*
1,5 ms
Switching Frequency (Interference-free Mode)
60 Hz
350 Hz
Response Time (Interference-free Mode)
6 ms
2,2 ms
*preset configuration
Table 5