background image

Operating Instructions

EN

Translation of the Original Operating Instruction  

Subject to change without notice

Available as PDF version only

Version: 1.1.0

Status: 04.12.2017

www.wenglor.com

P1KTxxx

Reflex Sensor

Содержание P1KT Series

Страница 1: ...rating Instructions EN Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 1 0 Status 04 12 2017 www wenglor com P1KTxxx Reflex Sensor ...

Страница 2: ...autions 6 2 6 Approvals and protection class 6 3 Technical Data 7 3 1 Accessory Products 8 3 2 Layout 8 3 3 Control Panel 9 3 4 Scope of Delivery 9 4 Transport and Storage 10 4 1 Transport 10 4 2 Storage 10 5 Installation and Electrical Connection 11 5 1 Installation 11 5 2 Electrical Connection 11 5 3 Diagnostics 12 6 Settings 13 7 I O Link 13 8 Maintenance Instructions 14 9 Proper Disposal 14 10...

Страница 3: ...symbols and attention getting words Safe use of the product is only possible if these safety precautions and warnings are adhered to The safety precautions and warnings are laid out in accordance with the following principle Attention Getting Word Type and Source of Danger Possible consequences in the event that the hazard is disregarded Measures for averting the hazard The meanings of the attenti...

Страница 4: ...pproved replacement parts Unapproved modification of products These operating instructions do not include any guarantees from wenglor with regard to the described procedures or specific product characteristics wenglor assumes no liability for printing errors or other inaccuracies contained in these operating instruc tions unless wenglor was verifiably aware of such errors at the point in time at w...

Страница 5: ...s Automotive industry Food industry Packaging industry Pharmaceuticals industry Plastics industry Woodworking industry Consumer goods industry Paper industry Electronics industry Glass industry Steel industry Aviation industry Chemicals industry Alternative energy Raw materials extraction 2 2 Use for Other than the Intended Purpose Not a safety component in accordance with 2006 42 EC Machinery Dir...

Страница 6: ...duct is modified Personal injury and damage to equipment may occur Non observance may result in loss of the CE marking and the guarantee may be rendered null and void Modification of the product is impermissible 2 5 General Safety Precautions NOTE These instructions are an integral part of the product and must be kept on hand for the entire duration of its service life In the event of possible cha...

Страница 7: ...equency speed mode 1000 Hz Response time 1 ms Response time speed mode 0 5 ms Temperature drift 10 Temperature range 40 60 C Switching output voltage drop 2 V Switching output switching current 100 mA Switching output residual current 50 µA Short circuit protection Yes Reverse polarity protected Yes Overload proof Yes Lockable Yes Interface IO Link IO Link version 1 1 Protection class III Output f...

Страница 8: ... Black 6 200 mm Table 2 3 1 Accessory Products wenglor can provide you with suitable connection technology for your product Suitable mounting technology no 400 Suitable connection technology no 7 S02 PNP NPN converter BG7V1P N 2M IO Link master wTeach2 software DNNF005 3 2 Layout 1 emitter diode 2 receiver diode M3 screw 0 5 Nm Potentiometer 40 Nmm Dimensions specified in mm 1 mm 0 03937 ...

Страница 9: ...Sensor 3 3 Control Panel 68 05 1K1 30 05 switching distance adjuster 30 switching status indicator contamination warning 68 supply power indicator 3 4 Scope of Delivery Sensor Safety precautions Mounting Set 01 ...

Страница 10: ...n the device making reference to damage in transit 4 2 Storage The following points must be taken into condition with regard to storage Do not store the product outdoors Store the product in a dry dust free place Protect the product against mechanical impacts Protect the product against exposure to direct sunlight ATTENTION Risk of property damage in case of improper storage The product may be dam...

Страница 11: ...nput inverted Trigger Input Analog Output Ground for the Analog Output Block Discharge Valve Output Valve Control Output Valve Control Output 0 V Synchronization Receiver Line Emitter Line Grounding Switching Distance Reduction Ethernet Receive Path Ethernet Send Path Interfaces Bus A B Emitted Light disengageable Magnet activation Input confirmation Contactor Monitoring Encoder A A TTL Encoder B ...

Страница 12: ...ing range Increase the sensor s switching distance Reduce distance between sensor and object Continuous blinking at approx 5 Hz Short circuit Check electrical wiring and eliminate the short circuit Over temperature Disconnect the sensor from supply power and allow it to cool down Hardware error Replace the sensor Contamination Warning Flowcharts not detected not detected detected beginning contami...

Страница 13: ...isk of personal injury or property damage in case of non compliance The system s safety function is disabled Personal injury and damage to equipment Required action as specified in case of fault 6 Settings Adjust and securely mount the sensor such that the spot strikes the object to be detected Turn the potentiometer all the way to the left Turn up the potentiometer until activation occurs and if ...

Страница 14: ...rn of unusable or irreparable products Respectively valid national waste disposal regulations apply to product disposal 10 Appendix 10 1 List of Abbreviations Abbreviation Meaning Tu Ambient temperature Ub Supply voltage IODD IO Device Description MTTFd Mean Time to Dangerous Failure 10 2 Change Index Operating Instructions Version Date Description Change 1 0 0 16 03 17 Initial version of the oper...

Страница 15: ...15 Reflex Sensor ...