background image

13

Reflex Sensors with Background Suppression

5.2 Electrical Connection

213

215

Legend

Wire Colors according to IEC 60757

Platinum measuring resistor
not connected
Test Input
Test Input inverted
Trigger Input
Ground for the Trigger Input
Analog Output
Ground for the Analog Output
Block Discharge
Valve Output
Valve Control
Valve Control Output 0 V
Synchronization
Ground for the Synchronization
Receiver-Line
Emitter-Line
Grounding
Switching Distance Reduction
Ethernet Receive Path
Ethernet Send Path
Interfaces-Bus A(+)/B(–)
Emitted Light disengageable
Magnet activation
Input confirmation
Contactor Monitoring 

Black
Brown
Red
Orange
Yellow
Green
Blue
Violet
Grey
White
Pink
Green/Yellow 

Supply V
Supply Voltage 0 V
Supply Voltage (AC Voltage)
Switching Output     

(NO)

Switching Output    

(NC)

Contamination/Error Output   (NO)
Contamination/Error Output   (NC)
Input (analog or digital)
Teach Input
Time Delay (activation)
Shielding
Interface Receive Path
Interface Send Path
Ready
Ground
Clock
Output/Input programmable

Power over Ethernet
Safety Input
Safety Output

Signal Output
Ethernet Gigabit bidirect. data line (A-D)  
Encoder 0-pulse 0-0 (TTL)

Encoder A/A (TTL)
Encoder B/B (TTL)
Encoder A
Encoder B
Digital output MIN
Digital output MAX
Digital output OK
Synchronization In
Synchronization OUT
Brightness output
Maintenance
reserved

PT

PT

DANGER!
Risk of personal injury or property damage due to electric current!

Voltage conducting parts may cause personal injury or damage to equipment.

 

• The electric device may only be connected by appropriately qualified personnel.

Содержание OPT2168

Страница 1: ...EN OPT2168 OPT2169 Reflex Sensors with Background Suppression Translation of the Original Operating Instruction Subject to change without notice Available as PDF version only Version 1 0 0 Status 16 1...

Страница 2: ...7 3 1 1 Spot Diameter 8 3 1 2 Switching Distance Deviation 9 3 2 Layout 9 3 3 Control Panel 10 3 4 Scope of Delivery 10 4 Transport and Storage 11 4 1 Transport 11 4 2 Storage 11 5 Installation and El...

Страница 3: ...emphasized by means of symbols and attention getting words Safe use of the product is only possible if these safety precautions and warnings are adhered to The safety precautions and warnings are lai...

Страница 4: ...unapproved replacement parts Unapproved modification of products These operating instructions do not include any guarantees from wenglor with regard to the described procedures or specific product ch...

Страница 5: ...industry Food industry Packaging industry Pharmaceuticals industry Plastics industry Woodworking industry Consumer goods industry Paper industry Electronics industry Glass industry Steel industry Avi...

Страница 6: ...eneral Safety Precautions NOTE These instructions are an integral part of the product and must be kept on hand for the entire duration of its service life In the event of possible changes the respecti...

Страница 7: ...wer 10 30 V DC IO Link supply voltage 18 30 V DC 40 60 C Switching output voltage drop 2 V Switching output switching current 100 mA Switching output residual current 50 A Short circuit protection Yes...

Страница 8: ...ption 20 mA Switching frequency Response time Switching frequency Interference free Mode Response time Interference free Mode Temperature drift 5 Temperature range 40 60 C Setting method Potentiometer...

Страница 9: ...on Kodak white 90 remission 30 50 70 90 110 130 150 2 0 4 6 8 10 Sr mm dSr mm P1KH BLUE Sr Switching Distance dSr Switching Distance Change Black 6 remission Grey 18 remission 3 2 Layout OPT2168 OPT21...

Страница 10: ...el 68 05 1K1 30 05 switching distance adjuster 30 switching status indicator contamination warning 68 supply power indicator 3 4 Scope of Delivery Sensor Safety precautions Laser warning label for Cla...

Страница 11: ...Then return the device making reference to damage in transit 4 2 Storage The following points must be taken into condition with regard to storage Do not store the product outdoors Store the product in...

Страница 12: ...ical influences Make sure that the sensor is mounted in a mechanically secure fashion Specified torque values must be complied with see section 3 Technical Data page 7 ATTENTION Risk of property damag...

Страница 13: ...nk Green Yellow Supply Voltage Supply Voltage 0 V Supply Voltage AC Voltage Switching Output NO Switching Output NC Contamination Error Output NO Contamination Error Output NC Input analog or digital...

Страница 14: ...approx 5 Hz Short circuit Check electrical wiring and eliminate the short circuit Over temperature Disconnect the sensor from supply power and allow it to cool down Hardware error Replace the sensor...

Страница 15: ...ckground or an Undersurface Adjust and securely mount the sensor such that the spot strikes the object to be detected at a right angle Turn the potentiometer all the way to the right Remove the object...

Страница 16: ...accept the return of unusable or irreparable products Respectively valid national waste disposal regulations apply to product disposal 10 Appendix 10 1 List of Abbreviations Abbreviation Meaning Tu A...

Отзывы: