background image

6

For Your Safety

2.  For Your Safety

2.1.  Use for Intended Purpose

The spectral composition of the colors of objects can be measured and analyzed with the OPT2022 6-band 
Multi-Spectral Sensor. Innovative color chip technology divides the selected color spectrum into six spec-
tral ranges (ROYGBV color space) with separately adjustable tolerance ranges. In combination with glass 
fiber-optic cables, the sensor adapts itself to the specific requirements of any given application and can be 
operated in the scanning as well as the through-beam mode. The Color Sensor is equipped with twelve 
switching outputs and integrated LED technology, which automatically ensures ideal adjustment of light inten-
sity. Sensor settings can be selected directly at the OLED display or via the IO-Link interface.

This product can be used in the following industry sectors:

• Automotive industry
• Food industry
• Packaging industry
• Pharmaceuticals industry
• Clothing industry
• Plastics industry
• Consumer goods industry
• Paper industry
• Electronics industry
• Glass industry
• Printing industry

2.2.  Use for Other than the Intended Purpose

• Not a safety component in accordance with the EC machinery directive.
• The product is not suitable for use in potentially explosive atmospheres.
• Only accessories supplied or approved by wenglor may be used with the product.

 

DANGER!

  Risk of personal injury or property damage in case of use for other than the intended purpose!
  Use for other than the intended purpose may lead to hazardous situations.

 

– Observe instructions regarding use for intended purpose.

 CAUTION! 

 

Danger of burns!

 

Some housing components heat up to 25 K above ambient temperature.

Содержание OPT2022

Страница 1: ...Available as PDF only Status 16 08 2018 Version 1 0 0 www wenglor com OPT2022 Color Sensor Operating Instructions EN ...

Страница 2: ...Safety Precautions 7 2 6 Laser LED Warnings 7 2 7 Approvals and IP Protection 7 3 Technical Data 8 3 1 Housing dimensions 9 3 2 Connection Diagram 10 3 3 Complementary Products 10 3 4 Layout 11 3 5 Control Panel 12 3 6 Scope of Delivery 12 4 Transport and Storage 12 4 1 Transport 12 4 2 Storage 12 5 Installation and Electrical Connection 13 5 1 Installation 13 5 2 Electrical Connection 13 5 3 Diag...

Страница 3: ... NO NC Output Function 19 7 6 NPN PNP 19 7 7 Switching Thresholds 20 7 8 Error or Contamination Output 20 7 9 Display 21 8 Interfaces 22 8 1 IO Link 22 9 Maintenance Instructions 22 10 Proper Disposal 22 11 Exclusion of Liability 22 12 Appendix 23 12 1 Index of Abbreviations 23 12 2 Change Index Operating Instructions 23 12 3 EU Declaration of Conformity 23 ...

Страница 4: ...possible if these safety precautions and warnings are adhered to The safety precautions and warnings are laid out in accordance with the following principle ATTENTION GETTING WORD Type and Source of Danger Possible consequences in the event that the hazard is disregarded Measures for averting the hazard The meanings of the attention getting words as well as the scope of the associated hazards are ...

Страница 5: ...ll liability in the event of Non compliance with the instructions Use of the product for purposes other than those intended Use by untrained personnel Use of unapproved replacement parts Unapproved modification of products 1 4 Copyrights The contents of these instructions are protected by copyright law All rights are reserved by wenglor Commercial reproduction or any other commercial use of the pr...

Страница 6: ...e selected directly at the OLED display or via the IO Link interface This product can be used in the following industry sectors Automotive industry Food industry Packaging industry Pharmaceuticals industry Clothing industry Plastics industry Consumer goods industry Paper industry Electronics industry Glass industry Printing industry 2 2 Use for Other than the Intended Purpose Not a safety componen...

Страница 7: ...ing and the guarantee may be rendered null and void 2 5 General Safety Precautions NOTES These instructions are an integral part of the product and must be kept on hand for the entire duration of its service life Read the operating instructions carefully before using the product Protect the sensor against contamination and mechanical influences Installation initial start up and maintenance of the ...

Страница 8: ...ing Output Voltage Drop 1 5 V PNP Switching Output Switching Current 100 mA Short Circuit Protection yes Reverse Polarity Protection yes Overload Protection yes Interface IO Link IO Link Version 1 1 Protection Class III Mechanical Characteristics Temperature Range 25 60 C Adjustment Teach in Degree of Protection IP67 Connection M12 1 4 8 pin DIN Rail mounting 35 mm Function Selectable menu languag...

Страница 9: ...9 OPT2022 3 1 Housing dimensions ...

Страница 10: ...ation Contactor Monitoring Encoder A A TTL Encoder B B TTL Black Brown Red Orange Yellow Green Blue Violet Grey White Pink Green Yellow Supply Voltage Supply Voltage 0 V Supply Voltage AC Voltage Switching Output NO Switching Output NC Contamination Error Output NO Contamination Error Output NC Input analog or digital Teach Input Time Delay activation Shielding Interface Receive Path Interface Sen...

Страница 11: ...y Connection Equipment M12 1 4 pin Suitable Connection Technology Connection Equipment M12 8 pin Suitable Connection Technology Fiber Optic Cables OPT2087 0 5 m OPT2089 1 0 m OPT2088 1 0 m OPT2075 1 0 m 3 4 Layout Receiving diode Emitter diode Display Control keys Plug 1 IO Link Plug 3 outputs Plug 2 outputs Mounting holes Spring loaded claw ...

Страница 12: ... accept the package and notify the manufacturer of the damage Then return the device making reference to damage in transit 4 2 Storage The following points must be taken into condition with regard to storage Do not store the product outdoors Store the product in a dry dust free place Protect the product against mechanical impacts Protect the product against exposure to direct sunlight ATTENTION Ri...

Страница 13: ...g the LED lens always connect a fiber optic cable or attach the rubber protector Attaching Glass Fiber Optic Cables Remove the protective cap from the sensor before attaching fiber optic cables Protect fiber optic cables from mechanical influences 1 Color Sensor 3 adapter No 1 2 wenglor Fiber Optic 4 Sleeve Nut ATTENTION Risk of property damage in case of improper installation The product may be d...

Страница 14: ...ER Risk of personal injury or property damage in case of non compliance The system s safety function is disabled Personal injury and damage to equipment Conduct in case of fault as specified 6 Overview of Functions 6 1 Default Settings OPT2022 Pin function A1 Switching Output A2 Switching Output A3 Switching Output A4 Switching Output A5 Switching Output A6 Switching Output A7 Switching Output A8 ...

Страница 15: ...During the first commissioning you can first of all select the menu language by simply pressing a button Switch to the configuration menu by pressing any key NOTE If no setting is made in the configuration setting for a duration of 30 s the sensor automatically jumps back into the display view By pressing the button once again the sensor jumps back to the menu view used last Settings made are adap...

Страница 16: ...n saver Switch Error Contaminate Tolerance Maximum Small Very large Very small Large Minimum Middle PNP NPN Push pull T for Teach In Teach OK NOK NO NC PNP NPN Push pull NO NC During Error Output or Contamination Output NPN PNP NO NC Mode Rotate Intensity During Switching Output T Windows T Sample Tolerance NPN PNP NO NC Display Depends on Pin Function A1 Switch A2 Switch A3 A12 Teach Output ...

Страница 17: ... 2 Run Sensor switches to display mode Set pin function A with correspond ing condition If A is not displayed it is deactivated in the pin function menu item Display of the current signal strength Legend Status LEDs Meaning Condition 1 Condition 2 Condition 3 Condition 4 Switching Output Switched Not switched Error Output Ok No signal Contamination Output Ok Signal too low Signal Strength Ok Signa...

Страница 18: ...tion Description T Windows Configuration of Pin A1 2 3 4 5 6 7 8 9 10 11 or 12 T for Teach in T Window teach in procedure 1 Align the spot to the background if there is one or the object 2 Press the T key The switching points are taught in NOTE T sample additional teach in of an OK or an NOK sample part in order to adjust tolerances Window width can be reduced or enlarged in the tolerance menu T S...

Страница 19: ...y open The output closes as soon as an object reaches the switching point NC Normally closed The output opens as soon as an object reaches the switching point 7 6 NPN PNP Function Description NPN PNP Output configuration PNP NPN Push pull 3 Back 33Run PNP A load or the evaluation device is connected between the negative pole supply and the output If switched the output is connected with the positi...

Страница 20: ...an be changed with interface The other values are calculated on the basis of hysteresis although hysteresis is not a fixed value itself but rather a calculated value as well 7 8 Error or Contamination Output When the pin is configured as an error or a contamination output the following functions can be selected Function Description A1 Error example Error output or contamination output NPN PNP NO N...

Страница 21: ...lay intensity Normal Power save Screen saver 3 Back 33Run Normal The intensity of the display is set to a normal value Power save The display switches off after one minute without a button being pressed and automatically switches back on when a button is pressed Screen saver The colors of the display are inverted every minute Mode Select display mode Digital Bar Graph 3 Back 33Run Digital The cond...

Страница 22: ...inting errors or other inaccuracies contained in these operating instruc tions unless wenglor was verifiably aware of such errors at the point in time at which the operating instruc tions were prepared Furthermore wenglor herewith explicitly informs the user that these operating instruc tions are only a general description of technical procedures whose implementation may not be suitable in all cas...

Страница 23: ...e negative Nr Number OLED Organic light emitting display PNP Positive negative positive Ub Operating voltage V Volts C Degrees Celsius K Kelvin 12 2 Change Index Operating Instructions Version Date Description Change Associated Software 1 0 0 17 11 16 Initial version of the operating instructions Firmware 1 0 0 12 3 EU Declaration of Conformity The EU declaration of conformity can be found on our ...

Отзывы: