16
EN
7.4.2 A3 Input
If Pin “A3” is used as input “Emitted light disengageable” or as input
“Offset”, the input can be set as an
inverted or non-inverted input.
Designation
Function
not invers
Usage as non-inverted input
A3 Input
not invers
invers
Normally, the input is at supply voltage “0”.
The functionality of the input is triggered upon applying a voltage > 7 V.
invers
Usage as inverted input
A3 Input
not invers
invers
The input is normally at a voltage of > 7 V.
The functionality of the input is triggered upon applying a voltage < 7 V.
7.5. A1 Analog/Analog
The measuring range for the analog output can be feely selected within the specified working range with rising
of falling characteristic curve.
The adjusted measuring range must have a value of at least 2 % of the total measuring range.
Note: The menu item is only present for the Sensors OPT2014 and OPT2012 if pin function “Analog” is set.