10
EN
Set Input
The Input can be used as follows: Emitted Light can be switched off at 24 V (La) or Emitted Light can be
switched off at 0 V (La).
• Rotary Selector Switch
Ý
to RxD/La Mode
è
The
U-LED
and I-
LED
indicate the current configuration.
RxD
is preset in the delivery status. By pressing
the Plus or the Minus key, the configuration can be changed.
Delivery Status
La
U-LED: ON
I-LED: OFF
U-LED: OFF
I-LED: ON
La
= Minus Button / LED
= Plus Button / LED
La
= Emitted Light can be switched off at 24 V
La
= Emitted Light can be switched off at 0 V
• Set the rotary selector switch
Ý
to
RUN
Adjustment of the Output
Configuring the analog output as a voltage output:
• Set the rotary selector switch
Ý
to
U / I MODE
è
The red
F-LED
lights up
è
If the yellow
U-LED
lights up: Analog output presently set to 0...10 V
è
If the yellow
I-LED
lights up: Analog output presently set to 4...20 mA
• Briefly press the plus-key
è
The Yellow
U-LED
lights up: Analog output reconfigured to 0...10 V (voltage output)
• Set the rotary selector switch
Ý
to
RUN
Configuring the analog output as a current output:
• Set the rotary selector switch
Ý
to
U / I MODE
è
The red
F-LED
lights up
è
If the yellow
U-LED
lights up: Analog output presently set to 0...10 V
è
If the yellow
I-LED
lights up: Analog output presently set to 4...20 mA
• Briefly press the minus-key
è
The yellow
I-LED
lights up: Analog output reconfigured to 4...20 mA (current output)
• Set the rotary selector switch
Ý
to
RUN
Operate the sensor with high resolution (Resolution-Mode)
• Set the rotary selector switch
Ý
to
RES. / SPEED-MODE
è
The red
F-LED
lights up
è
The yellow
U-LED
lights up: Sensor presently set to high speed
è
The yellow
I-LED
lights up: Sensor presently set to high resolution
• Briefly press the minus-key
The yellow
I-LED
lights up: Sensor now operates with high resolution.
• Set the rotary selector switch
Ý
to
RUN