4.4. Setting Switching Distance with the potentiometer
• Set rotary selector switch (07) to Poti
• Activate the plus button (24)
è
Switching Distance is increased
• Activate the minus button (25)
è
Switching Distance is reduced
The LEDs at the plus and minus buttons function like a light scale. The more brightly the respective button is
illuminated, the greater the sensing distance and vice versa.
The corresponding button blinks if maximum or minimum sensing distance has been selected.
• Set rotary selector switch (07) to Run
4.5. Setting Switching Distance with the Teach-In function
The ideal Switching Distance for the object to be recognized is selected automatically with the Teach-In function:
Normal Teach-In
Minimal Teach-In
Dynamic Teach-In
Two-point Teach-In
4.5.1. Normal Teach-In
• Set rotary selector switch (70) to Teach
è
Red LED (02) lights up
• Align spot to object
• Activate the plus button (24)
è
Plus button (24) lights up
• Activate the plus button (24) again*
è
Plus button (24) is no longer illuminated
• Set rotary selector switch (07) to Run
*If a second button operation does not take place within 40 seconds, the teach-in process is aborted without saving any settings.