18
Installation and Electrical Connection
5.3.1 Functional Earth
The FE terminal is located at the bottom front edge of the Connection Box. In order to assure proper functioning
in accordance with the EMC requirements specified in the data sheet, we recommend using our ground strap,
which is included in the scope of delivery (see
regarding tightening torque).
5.4 Port Assignments
Pin and port assignments for the network and the digital I/O ports are described below.
5.4.1 Industrial Ethernet Cable
wenglor offers a range of preassembled Industrial Ethernet cables.
In order to assure simple and reliable wiring, we recommend using out preassembled Industrial Ethernet
cables.
Pin assignments for Industrial Ethernet connection (D coded):
1
2
3
4
Pin
Function
1
TxD (+)
2
RxD (+)
3
TxD (–)
4
RxD (–)
NOTE!
• For connection to the controller, the connection cable from the controller must be con-
nected to the Connection Box via EtherCAT port x1. Please also note that the respective
downstream Connection Box must be operated via EtherCAT in port (x1). The field wire-
able ZAT50NN01 plug or suitable connection cables (see
) can, for example, be used for these connections.