Wenger Showmobile Mobile Stage and Canopy Скачать руководство пользователя страница 26

26

To avoid personal injury, use only 

authorized and trained personnel.

!

CAUTION

Use tie-downs to secure all 

equipment in Showmobile

!

CAUTION

Closing the Showmobile for Travel

Clear the Stage

Remove all equipment, and sweep all dirt, grit, and 

other debris from the stage�

Disconnect the Auxiliary Power

Disconnect the extension cord for the auxiliary 

electrical system�

Load Auxiliary Equipment

Load supplementary equipment such as lighting, 

sound systems, generator systems, chairs, etc�,  

into the Showmobile�

Important: 

Allow enough clearance for the hydraulic 

stage floor when it is folded up into its storage 

position�

Remove the Stairway(s)

Remove the stairways from their set position� Store 

them inside the Showmobile�

Load any Stage Extensions

Disconnect any auxiliary stage units from the stage 

floor. Store these units inside the Showmobile. 

 

Be sure to remove the connectors from the channels 

around the edge of the stage�
To provide proper weight distribution for towing, store 

the stage extensions and any other cargo in the front 

one-third of the Showmobile�

Secure the Equipment Inside the Unit

Secure all equipment inside the Showmobile so that 

it will not shift during transport� Shifting could cause 

damage and create a dangerous distribution of cargo 

weight. Tie-downs are located along the stage floor 

inside the Showmobile� Locate cargo near these tie-

downs, and securely tighten the tie-down straps which 

are provided� Do not exceed the 16,000 lb gross 

vehicle weight rating�

Lower the Roof/Canopy to the 

Intermediate Position

If the Showmobile is equipped with an optional lighting 

package, the canopy will need to be lowered for 

accessibility to fold up the lighting fixtures.

Set the roof/canopy switch at lower to lower the roof/

canopy partway down�  

Leave enough clearance for raising the hydraulic 

stage�

Raise the Hydraulic Stage

Move the flip-down panels upward to the storage 

position�

1�  Lift the panel slightly and move the leg upward to 

the magnetic latch�

2�  Lift the panel and lower it onto the main hydraulic 

stage�

3�  Latch the panel in place by placing the hook 

into the panel groove and then rotating the latch 

handle until it stops against the hook�

4.  Repeat step 1, 2, and 3 for the other flip-down 

panels�

Set the stage switch on the remote control to raise, 

until the hydraulic stage is in its vertical storage 

position� Return the legs to their original length 

position to avoid damage if there is an uneven surface 

when the stage is used next time� Check that the legs 

swing against their retaining magnets�

Lower the Roof/Canopy

If the Showmobile is equipped with an optional lighting 

package, watch and verify that nothing will contact the 

lighting fixtures while closing.

Set the roof/canopy switch on the remote control to 

lower, until the canopy leading edge fully contacts the 

roadside fender skirting�

Close the End Panels

Lift the end flaps. Unpin the end panel positioning 

braces, and lift and latch them against the vertical 

column structure� Close and lock the end panels�

Never lower the roof with people inside 

the Showmobile or under the roof.

!

CAUTION

Содержание Showmobile Mobile Stage and Canopy

Страница 1: ...sing with Stage in the Performance Position 25 Closing the Showmobile for Travel 26 Maintenance 28 Electrical Schematic 31 12V Wiring Diagram 34 Hydraulic Schematic 35 Troubleshooting 36 Owner s Manua...

Страница 2: ...on be liable for technical or editorial omissions made herein nor for direct indirect special incidental or consequential damages resulting from the use or defect of these instructions The manufacture...

Страница 3: ...s provide ventilation around the battery Do not charge or use booster cables or adjust post connections without proper training Keep batteries out of reach of children Batteries contain sulfuric acid...

Страница 4: ...re all doors Check each of the tires and wheels Check tires for wear damage and sidewall cracks Check tire inflation pressure as stated on sidewall Inspect the wheels for dents and cracks Tighten whee...

Страница 5: ...hat the load is evenly distributed and that the rating of the axles wheels tires tow vehicle hitch and other components are not exceeded The tow vehicle must be appropriately sized to the trailer Cons...

Страница 6: ...py Outlets standard Two duplex outlets on stage one duplex outlet by charger Additional outlets lighting upgrade Two quadplex and one duplex outlet in roof canopy Battery 12 volt BCI 8D Battery charge...

Страница 7: ...aulic Stage 28 32 40 14 6 16 4 x8 Versalite 2 x8 Versalite Specifications continued Typical Stage Configuration Main Stage Hydraulic Stage 28 32 40 14 6 18 6 20 Main Stage Hydraulic Stage 28 32 40 14...

Страница 8: ...he 12 volt electrical supply cord to the towing vehicle to operate the stop turn marker clearance and license plate lights and electrical brakes 5 Attach the breakaway cable to the towing vehicle Impo...

Страница 9: ...for opening and closing the roof canopy and hydraulic stage In the following procedures the sides and ends of the Showmobile are identified as indicated below Disconnecting the Towing Vehicle 1 Block...

Страница 10: ...w depending on whether your unit has a manual or hydraulic leveling system Note When leveling refer to the level indicators inside the round box on top of the hitch or use a 6 carpenter s level Manual...

Страница 11: ...from the control compartment and set its transmitter switch to on 4 Move one of the upper four switches to the raise corner position When that stabilizing jack is in contact with the ground and the c...

Страница 12: ...ot in use to save battery power When the performance is complete you will probably have to turn the timer switch back on see the previous note before you can close up the Showmobile Turning the transm...

Страница 13: ...the curb side of the Showmobile just to the rear of the control compartment A 50 cord with matching plug is provided with the standard 110 volt electrical system Important Auxiliary power must be conn...

Страница 14: ...There is a key lock in the handle assembly and also a hole for an optional padlock When not in use store the padlock in the control compartment 2 Press the release button and use the handle to open th...

Страница 15: ...efore opening the canopy See Leveling the Showmobile 4 Manual Leveling Model Activate the remote control by turning its key switch on 5 Open both end doors and lock them in position 6 With either remo...

Страница 16: ...rent spacings Only one set of inside and outside holes align at any time You may wish to raise the hydraulic stage slightly to adjust the length of each leg a Remove the locking pin from the first leg...

Страница 17: ...fully raised lower the canopy to the desired performance height 2 Manual Leveling Model Turn the key switch to off and remove the key Unplug the remote control module from the front of the Showmobile...

Страница 18: ...not attached to the Showmobile stage use only star shaped connectors Refer to the for additional clarification 1 Insert three gravity connectors into the extrusion on the edge of the Showmobile where...

Страница 19: ...tage For a Stage Extension For Wider Stage Wings Sample connections of optional stage units shown Additional units can be added to the sides or front or both Gravity Connector Star Connector Butterfly...

Страница 20: ...ng a Stairway 1 With two people lifting the stairway raise its lower end until you can slip the top of the two clamps on the stairway into the channel on the edge of the stage 2 Rotate the stairway ba...

Страница 21: ...controller pre programed for basic function from the factory 5 pin DMX override port for optional external control 5 upstage RGB batten downlights 4 high output canopy mounted LED profile fixtures CRI...

Страница 22: ...deploying or storing lights To avoid injury or damage lower the fixture batten with the help of another person When storing fixtures verify that all adjustment points are tightened Wenger Corporation...

Страница 23: ...ch 63 ch 65 ch 67 Performance Package Utility Lighting Package DMX Patching Information Optional Roof or Canopy Light Bars Optional roof or canopy light bars are installed at the factory When install...

Страница 24: ...desired 2 Pull down the end panel brace and use the stay pin to attach it to the bracket on the bottom of the end panel 3 Position the end panel where desired It can be set at three different positio...

Страница 25: ...Use the following procedure 1 Set the roof canopy switch on the remote control to lower Be careful so the roof canopy doesn t damage any equipment which is on the stage or suspended from the light ba...

Страница 26: ...e 16 000 lb gross vehicle weight rating Lower the Roof Canopy to the Intermediate Position If the Showmobile is equipped with an optional lighting package the canopy will need to be lowered for access...

Страница 27: ...en lowering the front and rear have become out of phase with each other i e one end is moving faster than the other This out of phase condition is most likely to occur within the first 5 to 10 seconds...

Страница 28: ...ot Bearings Once a year lubricate the bearings on the roof canopy pivot points 26 grease fittings total with an all purpose grease Battery Once a month check the 12 volt battery located in the front r...

Страница 29: ...k lug nuts for tightness within 10 miles after changing a tire and periodically thereafter Note The four corner jacks can also be used to raise the Showmobile so the tires can be changed Block under t...

Страница 30: ...gasket 089A573 40 feet 11 Check the hitch connection used to tow the vehicle 12 Check and clean the electrical plug used to tow the vehicle replace if necessary 13 Check the breakaway switch for the e...

Страница 31: ...31 Electrical Schematic Standard Units...

Страница 32: ...32 Electrical Schematic LED Lighting Upgrade...

Страница 33: ...ront road side corner Circuit Breakers in Electrical Load Center Electrical Schematic continued Location of Electrical Outlet Boxes 110 volt Units with Lighting Upgrade Standard Units Lighting Upgrade...

Страница 34: ...34 12 Volt Wiring Diagram...

Страница 35: ...35 Hydraulic Schematic Manual Leveling Model Hydraulic Leveling Model...

Страница 36: ...tive Function switch inoperative check Tx faceplate for loose wires or bad connections Possible failure in pump up circuit driver circuit relay not transferring voltage Call for a RGA Likely problem o...

Отзывы: