7
USER INSTRUCTIONS
CONTINUED
LIGHTING
CONTINUED
When two or more Stations are installed in a row, only the Station on the extreme right side has a switch
that controls all lights. The light Switch on Stations to the left controls only the top row and left column
of lights. if a Station to the left is used, it is necessary to turn on the lights for that Station and the Station
immediately to the right.
If this Station is used, it is necessary to
turn on the lights for this Station and the
Station immediately to the right.
This column of light is common to both
Stations and is controlled by the Station to
the right.
ELECTRIC RECEPTACLE
An electrical Duplex Receptacle is located on the lower right of the Mirror on each Makeup Station.
•
Appliances used to apply makeup can plug into this Receptacle.
•
This receptacle has Ground fault Circuit interrupter for shock protection.
Warning: Never plug appliances into the Receptacle that will exceed the current capacity of the
branch circuit. Overloading may cause a power interruption.
Warning: Never plug a device with faulty wiring into either of the two Receptacle outlets.
Failure to observe this precaution can result in injury or damage to property.
Warning: Never pour, spray, or splash liquids near the receptacle outlets. Failure to observe
this precaution can result in injury or damage to property.
Caution: Test the GFCI Receptacle every 30 days. Refer to page 12.
GfCi Receptacle
Test
Reset