INSTRUCTION MANUAL
INSTRUCTION MANUAL
OPERATION
CONNECTING TWO INVERTER GENERATORS
1. Place your parallel kit on a dry surface, such as dry ground
or the top of your generator.
2. The parallel kit has two sets of wires. Securely connect each
set of wires to each generator’s control panel. See Fig. 1.
• Insert the
red
plug into the
red
parallel connection port and
the
black
plug into the
black
port of each generator. If the
wires are not connected correctly, the generators will not out-
put any power.
• Attach the
green
wire with metal ring to each generators’s
grounding nut
.
NOTE:
Failure to properly ground the generator
or parallel kit can increase your risk of electric shock.
3. Once all the wires are correctly connected, start the inverter
generators one at a time, according to the instructions includ-
ed with your generator. The generator that has been started
first will be the primary generator.
4. Allow the generators to run for several minutes to stabilize
speed and output before plugging in your electrical device(s).
STORAGE
When the parallel kit is not in use, disconnect the kit from the inverters. Bind the cords around the parallel
kit body. Place the parallel kit back into its packaging for storage. Store in a well-ventilated, dry area.
If the parallel kit is to be left with the inverter, bind the cords together so as to prevent trampling of the plugs
and cords.
DISPOSAL
When the product reaches the end of its lifetime, please do not dispose of parts with your household waste.
This product contains components that should be recycled.
Please take this product to your local recy-
cling facility for responsible disposal to minimize its environmental impact.
2
3
Fig. 1
wires
Parallel
Connection Port on
Generator Panel
wires
NOTE:
The total rated power of your parallel kit is 6000W
(50A). Do not overload the receptacles.
NOTE:
The maximum voltage you can pull from the 14-50R outlet is 120V, you
cannot
pull 240V from it.
WARNING!
If the parallel kit is
placed on the ground, be careful not to
accidentally trample the wires.
WARNING!
Make sure both
generators are OFF and all electronic
devices are unplugged from the
generator and parallel connection
kit before plugging in your kit to the
generators.
No.
Part No.
Description
Qty.
1
GNA50i
50A Parallel Kit
1
2
GNA50i-002
Breaker, 50A
1
3
GNA50i-003
Breaker, 30A
1
4
GNA50i-004
Outlet, NEMA L5-30, 30A, 125V
1
5
GNA50i-005
Grounding Nut
1
6
GNA50i-006
Outlet, NEMA 14-50R, 50A, 125/250V
1
7
GNA50i-007
Waterproof Cover, L5-30R
1
8
GNA50i-008
Waterproof Cover, 14-50R
1
9
GNA50i-009
Screw, PT4x13
4
HAVE PRODUCT QUESTIONS? NEED TECHNICAL SUPPORT?
Please feel free to contact us:
1-800-232-1195 (M-F 8AM-5PM CST)
Replacement parts and the most up-to-date instruction manuals can be found on
wenproducts.com
.