Follow the steps below to properly connect your device(s) to the generator:

1. Before connecting electrical devices, allow the generator to run for a few minutes to stabilize the speed and volt-

age output. 

2. Select the device with the highest wattage, and make sure it is turned off. Plug the device into the matching gen-

erator outlet and then turn the device on. Allow the engine to stabilize. 

3. Repeat step 2 to plug in each additional device. Do not attempt to plug in or start multiple devices at the same 

time.

CONNECTING ELECTRICAL DEVICES

CAUTION: 

Become familiar with the functions and capacity of each component on the control panel (page 11) 

before connecting electrical devices. Do not overload generator or individual panel receptacles. Do not connect 

50Hz or 3-phase loads to the generator. 

IN CASE OF OVERLOAD

If your generator becomes overloaded from too much drawn wattage, the push-to-reset circuit breaker(s) on your 

control panel will activate and cut off the output. When an overload occurs, reduce the load by turning off and 

unplugging your electronic device(s), then press the activated circuit breaker to reset your generator. If the circuit 

breaker does not reset, wait several minutes and try again. If no power is produced after resetting, restart your 

generator. 

SOME NOTES ABOUT POWER CORDS

Long or thin extension cords can drain the power provided to your electrical devices. Refer to the following chart in 

determining the necessary gauge extension cord for each of your devices. Round up to the higher amperage in the 

chart to maximize safety.

USING YOUR GENERATOR

Table 3 - Power Cord Requirement Guide

*NR = Not Recommended

Device Requirements

Max. Cord Length (ft) by Wire Gauge

Amps

Watts 

(120V)

Watts (240V)

#8 wire

#10 wire

#12 wire

#14 wire

#16 wire

2.5

300

600

NR

NR

NR

375

250

5

600

1200

NR

NR

300

200

125

7.5

900

1800

NR

350

200

125

100

10

1200

2400

NR

250

150

100

50

15

1800

3600

NR

150

100

65

NR

20

2400

4800

175

125

75

50

NR

25

3000

6000

150

100

60

NR

NR

30

3600

7200

125

65

NR

NR

NR

40

4800

9600

90

NR

NR

NR

NR

WARNING!

 Generator should 

only

 be connected to electrical devices, either directly or with an extension 

cord. NEVER CONNECT TO A BUILDING ELECTRICAL SYSTEM unless a qualified electrician has connected the 

generator to a transfer switch as a separately derived system. Such connections must comply with local electri-

cal laws and codes. Failure to comply can create a back-feed, which may result in serious injury or death.

24

Содержание DF1100X

Страница 1: ...trouble free performance Pay close attention to the rules for safe operation warnings and cautions If you use your tool properly and for its intended purpose you will enjoy years of safe reliable serv...

Страница 2: ...utting Off the Generator 26 Maintenance 27 Transportation Storage 34 Troubleshooting Guide 35 Wiring Diagram 36 Exploded View Parts List 37 Warranty Statement 43 To purchase accessories and replacemen...

Страница 3: ...t Dimensions With Wheel Kit 27 3 in x 20 6 in x 21 9 in L x W x H GENERATOR Engine Type OHV 4 stroke single cylinder Engine Displacement 457cc Fuel Tank Capacity 6 6 US gallons 25 L 87 octane minimum...

Страница 4: ...________________ Purchased From _________________________________________________ Serial Number __________________________________________________ TO MAXIMIZE THE LIFESPAN OF YOUR GENERATOR We recomme...

Страница 5: ...ock PERSONAL SAFETY 1 Stay alert watch what you are doing and use com mon sense when operating a power tool Do not use a power tool while you are tired or under the influence of drugs alcohol or medic...

Страница 6: ...ordance with these instructions taking into ac count the working conditions and the work to be per formed Use of the power tool for operations different from those intended could result in a hazardous...

Страница 7: ...line Do not operate near open flame heat or any other ignition source Do not smoke near the generator Always operate on a firm level surface Always turn generator off before refueling Allow generator...

Страница 8: ...qualified technician Do not use receptacles or cords that show signs of damage such as broken or cracked insulation 4 Use a ground fault circuit interrupter GFCI in highly conductive areas such as met...

Страница 9: ...generator that be come hot during use 8 Turn off all connected electrical devices before stop ping the generator 9 Always turn generator off before refueling Allow generator to cool for at least 2 mi...

Страница 10: ...Fuel Tank 11 Control Panel Refer to the next page for descriptions 12 Battery Connect the battery before starting the generator 13 Oil Fill and Dipstick For filling and checking oil 14 Wheels 15 LPG H...

Страница 11: ...Push the button to reset the circuit 8 Grounding Nut Connection point for grounding the generator to the earth See p 19 for more information 9 NEMA L5 30R 120V 30A Twistlock Receptacle Connect electr...

Страница 12: ...he packaging until everything is removed Check the packing list below to make sure you have all of the parts and accessories If any part is missing or broken please contact customer service at 1 800 2...

Страница 13: ...through the wheel 42 flat washer 16 and wheel bracket on the frame 2 Insert cotter pin 25 through the hole on the end of the axle to keep the wheel in place 3 Repeat for the other wheel TO INSTALL TH...

Страница 14: ...nel or appropriate dispenser slowly add oil into the oil fill being careful not to overfill the unit Fill the crankcase to the upper fill line so you can visually see the oil coming halfway up the oil...

Страница 15: ...Do not fill to the top of the tank Allow for expansion Always check for spilled fuel before operating If fuel spills move the generator at least 30 feet away from the spill and wipe clean any spilled...

Страница 16: ...GAS LPG DANGER Explosion and fire LP vapors are extremely flammable and explosive Do not use or store LP cylinder in a building garage or enclosed area Failure to do so will result in death or seriou...

Страница 17: ...ght clockwise to tighten the as sembly onto the LPG tank Fig 7 3 Connect the other end of the hose to the generator s onboard regula tor with a 3 4 in 19mm wrench not supplied Fig 8 4 Turn the LPG tan...

Страница 18: ...ecoil start on LPG To connect the battery 1 Remove the red cover from the positive battery terminal 2 Connect the red cable to the positive battery terminal with the suitable nuts and bolts 3 Attach t...

Страница 19: ...er operation can be ensured by installing an altitude kit at altitudes higher than 2000 feet above sea level At elevations above 7000 feet the engine may experience a decrease in performance even with...

Страница 20: ...e a generator correctly CO may leak into the home ALWAYS use a battery powered or battery backup CO alarm in the home If you start to feel sick dizzy or weak after the generator has been running move...

Страница 21: ...electric starter 4 Insert the key and turn the engine switch to the START position for 2 3 seconds NOTE If the engine does not start release the switch and try again Keeping the switch in the START p...

Страница 22: ...you plan to connect The total running wattage This wattage should NOT exceed the running wattage of 8300W 7500W It is recommended to maintain a load at or below 7470W 6750W 90 of the rated output to...

Страница 23: ...00 1800 Saw Miter 1200 1200 Microwave 1000 0 Well Water Pump 1000 1000 Sump Pump 800 1200 Refrigerator Freezer 800 1200 Furnace Blower 800 1300 Computer 800 0 Electric Drill 600 900 Television 500 0 D...

Страница 24: ...our generator If the circuit breaker does not reset wait several minutes and try again If no power is produced after resetting restart your generator SOME NOTES ABOUT POWER CORDS Long or thin extensio...

Страница 25: ...sh air immediately and seek the attention of a qualified medical professional Follow all other directions in this manual regarding the connection and disconnection of electrical devices when starting...

Страница 26: ...electrical devices plugged in or turned on 2 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator CAUTION Allowing gasoline to sit in the fuel tank...

Страница 27: ...2 1195 M F 8 5 CST or email techsupport wenproducts com IMPORTANT GENERATOR MAINTENANCE TIPS Drain your carburetor after each use and before storage to prevent it from clogging Do not store the genera...

Страница 28: ...and blockages caused by stagnant fuel inside of the carburetor 1 Prepare an approved gasoline storage container under the carburetor to collect the drained fuel 2 The carburetor can be accessed from t...

Страница 29: ...oil mark reaches the top of the dipstick you can see oil coming up the threads of the oil fill Do not over fill 5 Reinstall dipstick and wipe clean any spilled oil with a rag Reinstall the oil access...

Страница 30: ...air filter element has been damaged replace it with a new one Replacement air filters can be ordered from wenproducts com by searching part no DF1100 175 1 4 Reinstall the air filter element and air...

Страница 31: ...ean any dirt from around the spark plug base then re gap the spark plug 5 Measure the plug gap with a spark plug gap gauge The gap should be 0 7 to 0 8 mm 0 028 0 031 in Fig 21 Carefully adjust the ga...

Страница 32: ...connection hardware NOTE Always recycle used batteries in accordance with local laws and regulations Contact your local solid waste collection site or recycling facility to obtain information on local...

Страница 33: ...outlet Fig 22 3 Connect a device to the outlet and turn it ON 4 With the device ON press the TEST button on the GFCI outlet The power to the device should be cut off instantly and the device should t...

Страница 34: ...r Run the engine for 15 to 20 minutes allowing the fuel stabilizer to mix with the gasoline and circulate through the carburetor and then top off with fuel Filling the fuel tank full reduces the amoun...

Страница 35: ...ack in one by one Bad connecting cords wires Check the power cords and extension cords Do not use if any cord is dam aged Replace damaged cords immediately Bad electrical device connected to the gener...

Страница 36: ...WIRING DIAGRAM 36 Neutral...

Страница 37: ...EXPLODED VIEW PARTS LIST GENERATOR 37...

Страница 38: ...Bolt M8X30 2 29 DF1100X 029 Panel Assembly 1 29 1 DF475 029 1 Ignition Switch 1 N P P55340 Starter Key set of 2 1 No Part No Description Qty 29 2 DF1100 029 4 Multi Meter 1 29 3 DF475 029 2 12V DC Re...

Страница 39: ...Clip 7 5mm 1 61 DF1100X 061 Fuel Line Clip 9 5mm 5 62 DF1100 062 Dustproof Sheet Right 1 63 DF475 004 Hex Head Screw M6x12 1 No Part No Description Qty 64 DF475 064 Nut M6 10 65 DF475 073 Fuel Tank Ca...

Страница 40: ...EXPLODED VIEW PARTS LIST ENGINE 40...

Страница 41: ...F1100 125 Valve Oil Seal 2 26 DF1100 126 Valve Spring 2 27 DF1100X 027 Fuel Line Carburetor 1 No Part No Description Qty 28 DF1100 128 Exhaust Valve Spring Seat 2 29 DF1100 129 Push Rod Guide Plate 1...

Страница 42: ...F1100 169 Carburetor Gasket 1 70 DF1100 170 Adjuster Rocker Arm 2 71 DF1100 171 Exhaust Pipe 1 72 DF1100 172 Governor Rod 1 No Part No Description Qty 73 DF1100 173 Throttle Return Spring 1 74 DF1100X...

Страница 43: ...o be sent to WEN before the replacements can be shipped out turning a product for warranty service the shipping charges must be prepaid by the purchaser The product must be shipped in its original con...

Страница 44: ...V 2021 10 18 THANKS FOR REMEMBERING...

Отзывы: