![Wen 56202i Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/wen/56202i/56202i_manual_956304020.webp)
MAINTENANCE
AIR FILTER MAINTENANCE
Routine maintenance of the air filter helps maintain proper
airflow to the carburetor. Occasionally check that the air filter is
free of excessive dirt. The air filter should be checked every 50
hours of use. Refer to Recommended Maintenance Schedule in
Fig. 20.
1. Unscrew the six Phillips head screws and remove the muffler
cover (Fig. 25 - 1). Then unscrew three hex bolts on the bottom
of the back cover and remove the back cover (Fig. 25 - 2).
2. Open the air filter cover (Fig. 26 - 1), and remove the air filter
foam element from the casing.
3. Check and clean the foam air filter element. Wash the filter
element in warm soapy water. Squeeze it thoroughly dry in a
clean cloth. Saturate the element in clean engine oil and squeeze
off excess oil in a clean absorbent cloth. A small amount of oil
in the element is normal and necessary for the engine to work
properly. If the element is damaged, replace it with a new one.
4. Reinstall the air filter element and close the air filter cover.
Close the back cover and muffler cover, and secure them with
the screws.
CAUTION:
Running the engine with dirty, damaged, or missing air filter element result in possible danger and
cause the engine to wear out prematurely.
Carburetor
Drain Screw
DRAINING THE CARBURETOR
Draining the carburetor is recommended to prevent the fuel from
clogging up the carburetor. A clogged carburetor can prevent the
generator from starting. The carburetor can be accessed from the
backside of the generator between the engine and the air filter.
1. Unscrew the six Phillips head screws and remove the muffler
cover (Fig. 25 - 1). Then unscrew three hex bolts on the bottom
of the back cover and remove the back cover (Fig. 25 - 2).
2. Open up the carburetor drain screw (Fig. 27) with a Phillips
screwdriver and drain out any gasoline that has built up inside the
carburetor.
3. Once the fuel has drained, tighten the drain screw with the
screwdriver. NOTE: Make sure to drain your carburetor before
storing the generator for long periods of time.
20
Fig. 25
Fig. 26
Fig. 27
1
2
1
4. Close the back cover and muffler cover, and secure them with the screws.