background image

       California Proposition 65 WARNING: 

This product contains chemicals and produces exhaust 

known to the State of California to cause cancer, birth defects and other reproductive harm.

       WARNING

: If this generator is used as a supply for a BUILDING’S WIRING SYSTEM, the generator 

MUST be installed by a qualified electrician and connected to a transfer switch as a separately derived 
system in accordance with all applicable laws and electrical codes and the National Electrical Code, 
NFPA 70. The generator shall be connected to a transfer switch that switches all conductors exclud-
ing the equipment grounding conductor. The frame of the generator shall be connected to an approved 
grounding electrode.

       WARNING

:

 RISK OF EXPLOSION. HIGHLY FLAMMABLE

: This generator may emit highly flam-

mable and explosive gasoline vapors, which can cause severe burns or even death, if ignited. A nearby 
open flame can lead to explosion even if not directly in contact with gasoline.

• Do not operate near open flame.
• Do not smoke near generator.
• Always operate on a firm, level surface.
• Always turn generator off before refueling. Allow generator to cool for at least 2 minutes before re-
moving fuel cap. Loosen cap slowly to relieve pressure in tank.
• Do not overfill fuel tank. Gasoline may expand during operation. Do not fill to the top of the tank. Allow 
for expansion.
• Always check for spilled fuel before operating.
• Empty fuel tank before storing or transporting the generator.
• Before transporting, turn fuel valve to OFF and disconnect spark plug wire.

GENERATOR SAFETY WARNINGS

      DANGER: CARBON MONOXIDE

Using a generator indoors 

CAN KILL YOU IN MINUTES. 

Generator exhaust contains carbon monox-

ide (CO). This is a poison gas you cannot see or smell. If you can smell the generator exhaust, you are 
breathing CO. But even if you cannot smell the exhaust, you could be breathing CO. 

NEVER use a generator inside homes, garages, crawl spaces, or other partially enclosed areas. Deadly 
levels of carbon monoxide can build up in these areas. Using a fan or opening windows and doors does 
NOT supply enough fresh air. ONLY use a generator OUTSIDE and far away from windows, doors, and 
vents. These openings can pull in generator exhaust.

Even if you use a generator correctly, CO may leak into the home. ALWAYS use a battery-powered or 
battery-backup CO alarm in the home. If you start to feel sick, dizzy, or weak after the generator has 
been running, move to fresh air RIGHT AWAY. See a doctor. You may have carbon monoxide poisoning.

5

Содержание 56155

Страница 1: ...ormance Pay close attention to the rules for safe operation warnings and cautions If you use your tool properly and for its intended purpose you will enjoy years of safe reliable service IMPORTANT MOD...

Страница 2: ...bleshooting Guide 25 Specifications 26 Wiring Diagram 27 Exploded View Parts List 28 Warranty Statement 32 SPECIFICATIONS Wattage 1350 Rated Watts 1550 Surge Watts Frequency 60Hz Rated Voltage AC 120V...

Страница 3: ...NUMBER WEN 56155 DATE OF PURCHASE __________________________________________ PURCHASED FROM ___________________________________________ SERIAL NUMBER _____________________________________________ SERV...

Страница 4: ...ormation regarding the generator s potential safety concerns as well as preparation operation and maintenance instructions Before operating this generator be sure to read and observe all warnings and...

Страница 5: ...nutes before re moving fuel cap Loosen cap slowly to relieve pressure in tank Do not overfill fuel tank Gasoline may expand during operation Do not fill to the top of the tank Allow for expansion Alwa...

Страница 6: ...asoline may expand during operation Do not fill to the very top of the tank Leave room for gasoline expansion Always check for spilled fuel before operating 3 If any part of the generator or electrica...

Страница 7: ...touching engine or areas of the gen erator that become hot during use 8 Turn off all connected electrical devices before stopping the generator 9 Always turn generator off before refueling Allow gener...

Страница 8: ...f any part is damaged or missing please contact our customer service at 800 232 1195 M F 8 5 CST or email us at techsupport wenproducts com KNOW YOUR GENERATOR 8 Circuit Breakers Top AC Breaker Bottom...

Страница 9: ...se is 13 5 fl oz The generator is equipped with a low oil sensor and will NOT start without a sufficient amount of oil To add oil follow these steps 1 Make sure the generator is shut OFF and on a leve...

Страница 10: ...el tank Fuel may expand during operation Do not fill to the top of the tank Allow for expansion Always check for spilled fuel before operating Clean up any spilled fuel before starting Empty fuel tank...

Страница 11: ...on can be ensured by installing an altitude kit at altitudes higher than 2000 feet above sea level At elevations above 7000 feet the engine may experience a decrease in performance even with the prope...

Страница 12: ...wered or battery backup CO alarm in the home If you start to feel sick dizzy or weak after the generator has been running move to fresh air RIGHT AWAY See a doctor You may have carbon monoxide poisoni...

Страница 13: ...the recoil starter handle slowly until a slight resistance is felt Then pull quickly to start the engine Return cord gently into the machine Never allow the cord to snap back 9 If engine fails to star...

Страница 14: ...connect The information should be listed on the device or in its instruction manual or you may refer to Fig 9 The wattage can be calculated using this equation Watts Volts x Amperes To calculate the...

Страница 15: ...rloaded This may result in overheating or stressing the machine s components possibly leading to generator failure CONNECTING THE DEVICES CAUTION Become familiar with the markings on the panel before...

Страница 16: ...mmended Fig 10 Power Cord Requirement Guide IN CASE OF OVERLOAD If your generator becomes overloaded from too much drawn wattage the circuit breaker s on your control panel will pop out and cut off po...

Страница 17: ...e switch to the OFF position 3 Turn the fuel valve to the OFF horizontal position CAUTION Unplugging running devices can cause damage to the generator Never stop the engine with electrical devices con...

Страница 18: ...mail techsupport wenproducts com RECOMMENDED MAINTENANCE SCHEDULE IMPORTANT GENERATOR MAINTENANCE TIPS Drain your carburetor after each use and before storage see page 19 to prevent it from clogging D...

Страница 19: ...ENERATOR Recommended to drain after every use and before storage Draining the carburetor is recommended to prevent the fuel from clogging up the carburetor A clogged car buretor can prevent the genera...

Страница 20: ...oil mark reaches the top of the dipstick you can see oil coming up the threads of the oil fill Do not over fill DRAINING THE OIL Change the oil according to the Recommended Maintenance Schedule in Fi...

Страница 21: ...searching 56180 073 5 Saturate the element in clean engine oil and squeeze off excess oil in a clean absorbent cloth Drip the sponge like element in clean engine oil meeting the requirements specified...

Страница 22: ...recommend replacing with a NGK BP7ES Torch E7TC spark plug Part No 56180 056 available for purchase at wenproducts com 4 If re using the spark plug use a wire brush to clean any dirt from around the s...

Страница 23: ...fuel is drained shut OFF the fuel valve 6 Follow the instructions in DRAINING THE CARBURETOR section on page 19 to drain the carburetor 7 Remove the fuel filter cup see FUEL FILTER CUP CLEANING below...

Страница 24: ...s 30 to 60 Days Drain the carburetor see page 19 Gasoline stored over 30 days can start to go bad and dam age fuel system components Add fuel stabilizer Follow the suggested portions and instructions...

Страница 25: ...ting a different device Generator runs but does not sup port all electrical devices con nected Generator is overloaded Turn off and unplug all electrical devices Wait 5 minutes then press the circuit...

Страница 26: ...8 lbs 25 3 kg Engine Type 4 stroke OHV single cylinder with forced air cooling system Engine Displacement 98cc Fuel Tank Capacity 1 1 US gallon 4 2 L 87 octane minimum Oil Capacity 13 5 fl oz Half Loa...

Страница 27: ...27 WIRING DIAGRAM...

Страница 28: ...63 56 57 58 59 54 53 52 55 43 44 45 46 47 48 49 50 51 2 3 11 12 13 14 15 16 17 18 7 64 22 23 24 25 26 28 29 27 30 31 33 22 34 35 36 24 39 38 42 37 40 32 41 21 20 19 4 10 9 8 5 6 EXPLODED VIEW PARTS L...

Страница 29: ...Engine End Cover 1 31 56180 013 1 Flange Bolt M5 10 3 32 56155 032 Voltage Regulator AVR 1 No Part No Description Qty 33 56155 033 Flange Bolt M8 185 1 34 56155 034 Flange Bolt M6 110 4 35 56155 035 W...

Страница 30: ...EXPLODED VIEW PARTS LIST ENGINE VIEW 30...

Страница 31: ...ystem 95 56180 095 Gulp Valve Gasket 96 56180 096 Gulp Valve Connection Plate 97 56180 097 Bolt M6X16 No Part Number Description 40 56180 040 Ignition Coil Assembly 41 56180 041 Head Cover Gasket 42 5...

Страница 32: ...ps resale shops or any other secondhand merchant void the warranty included with this product Contact techsupport wenproducts com or 1 800 232 1195 to make arrangements for repairs and transportation...