Schiffsuhr CHROM 232mm 

   Mod. 20804/IP ENI v3 

Marine clock CHROME 232mm

Art.-no. CW850346

 

V0618 

Verfügbare Uhrwerktechnologien 

Available clock movement technologies  

Modell 

Model 

Zeiger 

Hands 

Uhrwerktechnologie 
Movement technology 

20804/IP 

2 (Std./Min.) 

2 (h/m) 

Ethernet Nebenuhr selbstrichtend PoE (Power over Ethernet) 
Ethernet secondary clock self-setting PoE (Power over Ethernet) 

Klemmleiste / Terminal block 

Ersatzteile / spare parts 

TypE - T 

Type - IP 

Art.-No. 

Beschreibung / description 

ENI v3 

(WEMPE Ethernet 

Secondary clock interface) 

Connector RJ45 

Ethernet 10Base-T 

IPv4 

network cable 

twisted pair 

category 3 

and 

higher 

CW910008

CW950108 

CW910008G 

CW940007 

CW970014G 

CW940158 

Gehäuse Chrom Ø 232mm / case chrome Ø 232mm

Zifferblatt we/schw Strichz. / dial wh/bl markings 

Mineralglas gewölbt / mineral glass curved 

Uhrwerk TN / clock movement TN 

Zeigerpaar 104/139mm für TN /  
pair of hands 104/139mm for TN 

Netzwerk-Nebeuhreninterface ENIv3 
Ethernet slave clock interface ENIv3 

Содержание 20804/IP

Страница 1: ...d and glass frame Geh use Housing Messing hochglanz verchromt brass high gloss chrome plated Abmessungen mm Dimension mm 232 H he 65 232 height 65 Zifferblatt mm Dial mm Aluminium wei 230 aluminium wh...

Страница 2: ...mmleiste Terminal block Ersatzteile spare parts TypE T Type IP Art No Beschreibung description ENI v3 WEMPE Ethernet Secondary clock interface Connector RJ45 Ethernet 10Base T IPv4 network cable twist...

Страница 3: ...die Buchse am Zeiger etwas zusammengedr ckt werden Setzen Sie danach den Minutenzeiger auf die Minutenachse und ziehen Sie die Stiftschraube M2 der Buchse fest an Es ist darauf zu achten dass zwische...

Страница 4: ...ghtly squeezed Then place the minute hand on the minute arbour and tighten the pin screw M2 of the liner Please pay attention that there is enough space between the hands To check this turn the minute...

Страница 5: ...ce ENI Ethernet Secondary Clocks Interface Quick Start Guide valid for Hardware Rev 3 0 03 10 2016 Firmware V3 05 05 12 2016 V3 06 22 12 2016 Secondary Clock Ethernet Interface Compatible with Wempe M...

Страница 6: ...tatic by default This can be changed to obtain addresses from a DHCP server The DHCP query asks for addresses of NTP servers too If the DHCP server provides them up to two addresses will be mentioned...

Страница 7: ...to reconnect the web browser after a few seconds Further ENI configuration can be done on the Master Clock s web interface see it s manual Master Clock Rev Master Clock Software Version1 Select ENI V...

Страница 8: ...subnet This option requires a working DHCP server on the same subnet that the ENI is connected to Set_MIN Force the network initialization to use the static IP address 172 16 0 100 which is the facto...

Страница 9: ...ng off INIT Can t finish initialization most likely the device is damaged MAC No physical network connection LINK Network up but doesn t respond to IP requests CONN Network up but no IP address possib...

Страница 10: ...one user name and one password There is no way to add or delete account names There is no limit in the count of failed logins due to wrong passwords To protect the web interface access against brute...

Страница 11: ...s from PC to ENI and back The ping tool on the Tools page of the web interface see ENI user manual can assist Check any blocking features firewall etc at every routing device between ENI and PC Try us...

Страница 12: ...2 to set the correct protocol version Check the IP addresses of ENI and masterclock are in the same IP subnet or VLAN The ping tool on the Tools page of the web interface see ENI user manual can assis...