CA
T-OWL
G/OWLS-QSG-
V1.0 EN ed.
01/2021
W
elotec GmbH
Welotec GmbH
www.welotec-sensors.com
Zum Hagenbach 7
D-48366 Laer
[email protected]
+49 2554 9130 00
OWLG/OWLS Series
INSTALLATION INSTRUCTIONS
CONNECTION DIAGRAM
PIN ASSIGNMENT
LASER
1
BN
Brown
2
WH
White
3
BU
Blue
4
BK
Black
1
+Vs
2
teach in
3
0 V
4
analog
If the teach-in line is not used, set it to 0 V.
Operating voltage range: +Vs = 12 - 28 VDC.
Disconnect power from the system before connecting the device. Power supply according to UL 1310, Class2 or
external fuse protection by a UL recognized or listed fuse with max. 100 W/Vp or max. 5 A under 20 V.
Note on electromagnetic compatibility: Shielded connection cable recommended. Ground the cable shield on
both sides, over a large area, and ensure potential equalization.
Depending on the version, the product has laser class 1 or laser class 2 (see data sheet). The
following applies to laser class 2
•
Laser radiation!
•
Do not look into the laser beam.
•
Class 2 laser product.