Welltech Computer Co., Ltd.
Advance Trunk Configuration:
Start Path: Configuration
→
Interface
→
Trunk
→
Advance
Figure 6.3-2
Advance Parameter Description:
•
Interface ID: System parameter
•
Trunk ID: System parameter
•
Dest Num Plan: ISDN destination number plan
•
Src Num Type: ISDN source number type
•
Dest Num Type: ISDN destination number type
•
Src Num Presen: ISDN source number presentation
•
Src Num Screen: ISDN source number display
•
Input Gain: Voice Gain from IP to PSTN side (default: 0 db)
•
Output Gain: Voice Gain from PSTN to IP side (default: 0 db)
•
Q.931 General Opt.: used for Q.931 general behavior.
o
0x0001: No Status message send for unknown facility IE if it is set
o
0x0002: No Status message send for invalid content of a valid facility IE if
it is set
o
0x0080: Send Connect Ack message when receive Connect message if it is
set, you can OR the required option together
•
Q.931 Incoming Opt.: used for Q.931 incoming call behavior
o
0x0800: include Channel-ID IE in the first reply message (e.g. Call
Proceeding or Alerting)
o
0x2000: enable the system to include Channel-ID IE in the Call
Proceeding message, you can OR the required option together
•
Q.931 Outgoing Opt.: used for Q.931 outgoing behavior
o
0x0010: use Mu-law if this bit is set, or A-law will be used. Apply only for
Korea variance, you can OR the required option together
•
Trans Cap: Transfer Capability
o
Voice Service
o
Date Service
o
Modem Service
WellGate 5200 User Guide - V3