WIRING DIAGRAM 

10 

LLF-14 FRYER WIRING DIAGRAM, 120V and 240V 

Содержание Model LLF-14

Страница 1: ...MINATION OF THIS INFORMATION TO ANYONE OTHER THAN WELLS AUTHORIZED SERVICE AGENTS IS STRICTLY PROHIBITED TECHNICAL CONTENT OF THIS MANUAL IS DESIGNED FOR USE BY QUALIFIED PROFESSIONAL TECHNICIANS ONLY SERVICE MANUAL MODEL AAA AAA 305 p n 504367 Rev S305 121001 cps SERVICE MANUAL MODEL LLF 14 COUNTERTOP FRYER Includes TROUBLESHOOTING SUGGESTIONS SERVICING INSTRUCTIONS EXPLODED VIEW PARTS LIST WIRIN...

Страница 2: ...nel Any procedure which requires the use of tools must be performed by a qualified technician This manual is considered to be a permanent part of the appliance This manual and all supplied instructions diagrams schematics parts breakdown illustrations notices and labels must remain with the appliance if it is sold or moved to another location This appliance is made in the USA Unless otherwise note...

Страница 3: ...OR HI LIMIT 6 REPLACE SUPPORT ROD SPRING 7 EXPLODED VIEW 8 PARTS LIST 9 WIRING DIAGRAM 10 ELECTRICAL SCHEMATIC 11 This manual contains the information needed to properly service and repair this equipment TABLE OF CONTENTS SPECIFICATIONS INTRODUCTION MODEL VOLTS AMPS WATTS POWER CORD LLF 14 120 VAC 1ø 15 A 1 800 W NEMA 5 15P 208 VAC 1ø 240 VAC 1ø 16 2A 18 8A 3 400W 4 500W NEMA 6 30P 1 ...

Страница 4: ...FEATURES OPERATING CONTROLS 2 Fig 1 LLF 14 Features Operating Controls ...

Страница 5: ...ts For best results load baskets uniformly to half full b Using the basket handle lower the baskets into the hot oil c When food is cooked lift the basket out of the oil by the handle Hang the baskets on the BASKET SUPPORT ROD to drain 5 When the heat indicator light cycles off the fryer is ready to cook the next load 6 Reduce temperature control to 225ºF during idle periods to save power and exte...

Страница 6: ...rt rod spring Heat indicator does not light operation OK Defective indicator light Loose or defective wiring Replace indicator Repair wiring tighten connectors 1 The hi limit safety is designed to shut down the fryer is the oil temperature exceeds 440ºF A build up of cooking debris between the heating element and the thermobulb of the hi limit safety will cause the hi limit to trip prematurely Cle...

Страница 7: ... Reconnect wiring to the element terminals 5 Reinstall the thermobulbs Be sure the wire ring is intact and in place at each end of the thermobulb Snap a bulb clip over the element and over each end of bulb to secure the bulb to the element The wire rings must be between the bulb clips Carefully route the capillary tube and secure with three capillary clips Repeat for both bulbs 6 Reinstall handle ...

Страница 8: ...ol box 3 Reconnect wiring to the thermostat terminals Connect wiring then attach the thermostat to the control box 4 Reinstall the thermobulbs Be sure the wire spacing rings are intact and in place at each end of the thermobulb Snap a bulb clip over the element and over each end of bulb to secure the bulb to the element The wire spacing rings must be between the bulb clips Carefully route the capi...

Страница 9: ... 1 Position the support rod toward the back power cord side of the control box then slide the new spring over the split end of the support rod Note orientation Long leg of spring at the top and pointing toward the front short leg of spring in the slot 2 Using pliers squeeze the split end of the support rod to capture the spring 3 Tension the spring by swinging the long leg clockwise and allowing i...

Страница 10: ...EXPLODED VIEW 8 Fig 12 LLF 14 Exploded View ...

Страница 11: ... 65765 SHELL ASSEMBLY 1 102 65767 BRACKET PIVOT 2 103 53436 WASHER SLOTTED PIVOT 2 104 55747 GASKET FRYER HEAD pk 12 2 111 65774 CONTROL BOX 1 112 55028 COVER CONTROL BOX 1 131 LABEL HI LIMIT RESET 1 132 LABEL FACEPLATE 1 133 LOGO WELLS DOMED 1 151 20169 FRYPOT 1 201 21506 FRY BASKET HALF SIZE 2 ITEM P N DESCRIPTION QTY a1 55566 SCREW TRS SS 6x1 4 pk 100 8 a2 53890 SCREW 12 24x3 4 pk 10 4 b1 55736...

Страница 12: ...WIRING DIAGRAM 10 LLF 14 FRYER WIRING DIAGRAM 120V and 240V ...

Страница 13: ...WIRING SCHEMATIC 11 LLF 14 FRYER SCHEMATIC 120V and 240V ...

Страница 14: ...RIZED SERVICE AGENTS IS STRICTLY PROHIBITED TECHNICAL CONTENT OF THIS MANUAL IS DESIGNED FOR USE BY QUALIFIED PROFESSIONAL TECHNICIANS ONLY WELLS MANUFACTURING COMPANY DIVISION OF CARRIER REFRIGERATION 2 ERIK CIRCLE P O Box 280 Verdi NV 89439 Customer Service 775 345 0444 Ext 502 fax 775 345 0569 www wellsbloomfield com ...