Wells MOD-400TDMAF Скачать руководство пользователя страница 6

NOTE:

  DO NOT discard 

the carton or other packing 
materials until you have 
inspected the appliance for 
hidden damage and tested it 
for proper operation. 
Refer to 

SHIPPING DAMAGE 

CLAIM PROCEDURE 

on the 

inside front cover of this 
manual. 
 

 

WARNING: 

RISK OF  INJURY 

 

Installation procedures must 
be performed by a qualified 
technician with full knowledge 
of all applicable electrical and 
plumbing codes.  Failure can 
result in personal injury and 
property damage. 

 

 

CAUTION 

FIRE HAZARD 

 

Avoid storing flammable or 
combustible materials in, on 
or near the appliance. 
 
 

IMPORTANT:  

For warmers 

installed in plastic counter 
tops, the counter material 
must be protected from the 
heat of the warmer in order to 
prevent discoloration and/or 
deterioration.  Wellsloks are 
not suitable for this purpose.  
The installer should contact 
the  manufacturer or distributor 
of the countertop material for 
specific instructions.  

 

 

IMPORTANT

:  Wellslok       

Extension Kits must be used 
ONLY with  UL Listed      
warmers approved  for          
installation in wood counter 
tops. Refer to the 

Installation 

Instructions

 provided with the 

warmer. 

UNPACKING & INSPECTION 

 

Carefully remove the appliance from the carton.  Remove all  
protective plastic film, packing materials and accessories from the 
Appliance before connecting electrical power or otherwise performing 
any installation procedure. 

 

Carefully read all instructions in this manual and the 

Installation 

Instruction Sheet

 packed with the appliance before starting any 

installation. 

 

Read and understand all labels and diagrams attached to the 
appliance. 

 

Carefully account for all components and accessories before 
discarding packing materials.  Store all accessories in a convenient 
place for later use.

 

 

INSTALLATION NOTES 

 

     1.  Installation and start up of built-in warmers MUST be performed 
 

 

by an authorized installation company. 

     2.  It is the RESPONSIBILITY OF THE INSTALLER to verify that 
 

 

this warmer installation is in  compliance with the specifications 

 

 

listed in this manual and on the specification sheet provided.  

     3.  It is the RESPONSIBILITY OF THE INSTALLER to check with 
 

 

the AUTHORITY HAVING JURISDICTION, in order  to verify 

 

 

that this warmer installation is in compliance with local code  

   requirements. 
 

4.  Water supply and drain installation must meet all applicable   

 

 

local, state and federal plumbing codes and ordinances. 

 5. 

Refer 

to 

Installation Instructions

 included with the warmer for                

 

 

Underwriters Laboratories conditions of acceptability, electrical          

 

 

requirements and other installation concerns. 

 

BUILT-IN WARMERS

 

 

     1.  This is a GENERAL GUIDE.  For specific cutout dimensions  
 

 

and other installation details, refer to the 

Installation               

   Instructions

 supplied with the warmer.   

 

2.  Cutout dimensions for warmer units and control panels are  

 

 

listed on the 

Installation Instructions 

 provided with the warmer. 

 

 

 

NOTE

:  Cutout dimensions are different for auto-fill and non-auto-fill 

 

control panels, for single and split control panels and for wood and 

 

metal counters.  Verify the dimensions are correct for the            

 

installation before making the cutout. 

 

      

 

INSTALLATION 

 M

011C.14 

 2M
-308025 

  Owne

rs M

anual for 

Bu
ilt-In

 Four

-W

ell

 Au
to-Fill

 M

odular 

W

armer

Содержание MOD-400TDMAF

Страница 1: ...ERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if...

Страница 2: ...FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merchandise is unpacked notify the transportation company or carrier immediat...

Страница 3: ...appliance will ensure that it gives you the very best performance and a long economical service life This manual contains the information needed to properly install this appliance and to use and care...

Страница 4: ...indication of the temperature setting Actual temperature will vary depending upon the type of product and food consistency B MOUNTING 1 Top mounted built in warmers may be equipped with WELLSLOKS uniq...

Страница 5: ...s must be read and understood by all persons using or installing this appliance Cleanliness of this appliance is essential to good sanitation Read and follow all included cleaning instructions and sch...

Страница 6: ...installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all accessories in a c...

Страница 7: ...Code E PLUMBING INSTALLATION For use in the State of Massachusetts this appliance must be installed in compliance with Massachusetts Fuel Gas and Plumbing Code CMR 248 1 IMPORTANT All plumbing install...

Страница 8: ...2 qt 4qt 7 qt and 11 qt sizes with lids and adapter tops b For dry operation a 6 deep pan or inset is recommended 2 Turn temperature control to HI or highest temperature setting 3 Allow warmer to pre...

Страница 9: ...ells Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainless steel however is mostly iron and will rust pit and corrode under the fol...

Страница 10: ...spect warmer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water to leak into insulation and heating element causing a potential fir...

Страница 11: ...gher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control OFF Cover pans 4 Allow solution to soak at least one hour or overnight...

Страница 12: ...in valve not fully closed Check drain valve for debris and close fully Drain valve damaged or pan s leaking Contact your Authorized Wells Service Agency for repairs Auto fill unit overflows Water leve...

Страница 13: ...ATER FILL 48111 J 22 THERMOSTAT 51 50 GRN PROBE WATER PAN MALE FEMALE CONNECTOR TERM BLOCK SINGLE PHASE SINGLE PHASE HEATING ELEMENT 4 27 5 23 8 11 3 17 8 17 8 9 8 14 5 14 5 HZ 60 50 L3 L2 L1 LOW WATE...

Страница 14: ...C 46591 2H 36196 sold by the foot D8 303352 ELEMENT PAN ASSY WS 503843 208 240V ELEMENT PAN KIT WS 503842 ELEMENT ONLY 2N 303375UL 208 240V THERMOBULB ref P2 35004 P2 35004 2H 36050 sold by the foot P...

Страница 15: ...50 WS 503713 2K 47662 2K 48197 2K 48198 2C 46591 2H 36050 sold by the foot 2H 36196 sold by the foot D8 303352 ELEMENT PAN ASSY WS 503843 208 240V ELEMENT PAN KIT WS 503842 ELEMENT ONLY 2N 303375UL 20...

Страница 16: ...88 2J 35687 2T 45917 2K 31040 OFF 0 L O H I WELLS WELLS 2 3 4 5 6 7 8 WS 50131 2C 41974 E7 49046 2R 40498 2K 31040 2E 306865 2I 40034 2E 46529 2C 46591 2J 35687 WS 50131 2C 41974 2T 45917 2I Z12311 2K...

Страница 17: ...3352 ELEMENT PAN ASSEMBLY WS 503843 208 240V ELEMENT PAN KIT WS 503842 ELEMENT ONLY 2N 303375UL 208 240V THERMOBULB ref 2H 36050 sold by the foot P2 300712 2V 35609 PAN ASSY QTY 1 WS 504101 500700 5P...

Страница 18: ...rt 12 x 20 warmer to hold one 7qt and one 4 qt DD 21618 ADAPTER TOP convert 12 x 20 warmer to hold four 2 qt insets 5D 21623 ADAPTER TOP convert 12 x 27 SMPT 27 to hold three 7 qt insets DD 21503 4 QT...

Страница 19: ...proved for installation in wood counter tops One well units require one kit Two and three well units require two kits four and five well units require three kits DRAIN VALVE EXTENSION KIT extension fr...

Страница 20: ...STOMER SATISFACTION Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association PRINTED IN UNITED STATES OF AMERICA Commercial Food Equipment Service Association WELLS BLOOMF...

Отзывы: